Optimization of the Spatial Resolution for the GE Discovery PET/CT 710 by Using NEMA NU 2-2007 Standards

被引:15
|
作者
Yoon, Hyun Jin [1 ]
Jeong, Young Jin [1 ]
Son, Hye Joo [1 ]
Kang, Do-Young [1 ]
Hyun, Kyung-Yae [2 ]
Lee, Min-Kyung [3 ]
机构
[1] Dong A Univ, Dept Nucl Med, Pusan 602715, South Korea
[2] Dong Eui Univ, Dept Clin Lab Sci, Pusan 614714, South Korea
[3] Dong Eui Univ, Dept Dent Hyg, Pusan 614714, South Korea
关键词
Electrical Manufacturers Association (NEMA); Positron emission tomography (PET); Spatial resolution; Iterative reconstruction algorithm; VARIANT SYSTEM MODEL; PERFORMANCE-MEASUREMENTS; ATTENUATION CORRECTION; RECONSTRUCTION;
D O I
10.3938/jkps.66.287
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The spatial resolution in positron emission tomography (PET) is fundamentally limited by the geometry of the detector element, the positron's recombination range with electrons, the acollinearity of the positron, the crystal decoding error, the penetration into the detector ring, and the reconstruction algorithms. In this paper, optimized parameters are suggested to produce high-resolution PET images by using an iterative reconstruction algorithm. A phantom with three point sources structured with three capillary tubes was prepared with an axial extension of less than 1 mm and was filled with F-18-fluorodeoxyglucose (F-18-FDG) with concentrations above 200 MBq/cc. The performance measures of all the PET images were acquired according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standards procedures. The parameters for the iterative reconstruction were adjusted around the values recommended by General Electric GE, and the optimized values of the spatial resolution and the full width at half maximum (FWHM) or the full width at tenth of maximum (FWTM) values were found for the best PET resolution. The axial and the transverse spatial resolutions, according to the filtered back-projection (FBP) at 1 cm off-axis, were 4.81 and 4.48 mm, respectively. The axial and the transaxial spatial resolutions at 10 cm off-axis were 5.63 mm and 5.08 mm, respectively, and the trans-axial resolution at 10 cm was evaluated as the average of the radial and the tangential measurements. The recommended optimized parameters of the spatial resolution according to the NEMA phantom for the number of subsets, the number of iterations, and the Gaussian post-filter are 12, 3, and 3 mm for the iterative reconstruction VUE Point HD without the SharpIR algorithm (HD), and 12, 12, and 5.2 mm with SharpIR (HD.S), respectively, according to the Advantage Workstation Volume Share 5 (AW4.6). The performance measurements for the GE Discovery PET/CT 710 using the NEMA NU 2-2007 standards from our results will be helpful in the quantitative analysis of PET scanner images. The spatial resolution was modified more by using an improved algorithm such as HD.S, than by using HD and FBP. The use of the optimized parameters for iterative reconstructions is strongly recommended for qualitative images from the GE Discovery PET/CT 710 scanner.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 36 条
  • [31] Variability in NEMA NU 2-2012 performance measurements of all sixteen Discovery MI digital time-of-flight PET-CT systems in the Nordic countries
    Lubberink, M.
    Ilan, E.
    Moreno, A.
    Oddstig, J.
    Svegborn, S. Leide
    Braad, P.
    Lonsdale, M. Nowak
    Hjornevik, T.
    Mikalsen, L. Gyland
    Gjervan, V.
    Tolvanen, T.
    Sipila, O.
    Hindorf, C.
    Tragardh, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S206 - S206
  • [32] Characterization and optimization of image quality as a function of reconstruction algorithms and parameter settings in a Siemens Inveon small-animal PET scanner using the NEMA NU 4-2008 standards
    Visser, Eric P.
    Disselhorst, Jonathan A.
    van Lier, Monique G. J. T. B.
    Laverman, Peter
    de Jong, Gabie M.
    Oyen, Wim J. G.
    Boerman, Otto C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 357 - 367
  • [33] Performance Characteristics of a New Generation 148-cm Axial Field-of-View uMI Panorama GS PET/CT System with Extended NEMA NU 2-2018 and EARL Standards
    Zhang, Haiqiong
    Ren, Chao
    Liu, Yu
    Yan, Xinchun
    Liu, Meixi
    Hao, Zhixin
    Xing, Haiqun
    Huo, Li
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65 (12) : 1974 - 1982
  • [34] NEMA NU 2-2018 evaluation and image quality optimization of a new generation digital 32-cm axial field-of-view Omni Legend PET-CT using a genetic evolutionary algorithm
    Smith, Rhodri Lyn
    Bartley, Lee
    O'Callaghan, Christopher
    Haberska, Luiza
    Marshall, Chris
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (02)
  • [35] Quantification of pancreatic uptake in beta cell imaging with 68Gaexendin PET/CT using a 3D-printed anatomical pancreas-kidneys phantom and the NEMA NU2 Image Quality phantom
    Deden, L. N.
    Buitinga, M.
    Meeuwis, A. P. W.
    Ruiter, S.
    Lobeek, D.
    Gotthardt, M.
    Visser, E. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S525 - S526
  • [36] Optimizing the Performance evaluation tests of Gemini TF64 PET/CT scanner using 68Ga isotope adhering NEMANU-2 2007 standards
    Rawat, B.
    Sawant, V.
    Jha, A. K.
    Mithun, S.
    Rangarajan, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S599 - S599