Comparing the accuracy of open-source pose estimation methods for measuring gait kinematics

被引:27
|
作者
Washabaugh, Edward P. [1 ,2 ]
Shanmugam, Thanikai Adhithiyan [2 ]
Ranganathan, Rajiv [3 ]
Krishnan, Chandramouli [2 ,4 ,5 ,6 ]
机构
[1] Wayne State Univ, Dept Biomed Engn, Detroit, MI USA
[2] Michigan Med, Dept Phys Med & Rehabil, Ann Arbor, MI USA
[3] Michigan State Univ, Dept Kinesiol, E Lansing, MI USA
[4] Univ Michigan, Michigan Robot Inst, Ann Arbor, MI USA
[5] Univ Michigan Flint, Coll Hlth Sci, Dept Phys Therapy, Flint, MI USA
[6] Univ Michigan, Dept Phys Med & Rehabil, Michigan Med, 325 E Eisenhower Pkwy Suite 3013, Ann Arbor, MI 48108 USA
基金
美国国家科学基金会;
关键词
Low-cost; Angle; Impairment; Training; Rehabilitation; VALIDITY;
D O I
10.1016/j.gaitpost.2022.08.008
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Open-source pose estimation is rapidly reducing the costs associated with motion capture, as ma-chine learning partially eliminates the need for specialized cameras and equipment. This technology could be particularly valuable for clinical gait analysis, which is often performed qualitatively due to the prohibitive cost and setup required for conventional, marker-based motion capture. Research Question: How do open-source pose estimation software packages compare in their ability to measure kinematics and spatiotemporal gait parameters for gait analysis? Methods: This analysis used an existing dataset that contained video and synchronous motion capture data from 32 able-bodied participants while walking. Sagittal plane videos were analyzed using pre-trained algorithms from four open-source pose estimation methods-OpenPose, Tensorflow MoveNet Lightning, Tensorflow MoveNet Thunder, and DeepLabCut-to extract keypoints (i.e., landmarks) and calculate hip and knee kine-matics and spatiotemporal gait parameters. The absolute error when using each markerless pose estimation method was computed against conventional marker-based optical motion capture. Errors were compared be-tween pose estimation methods using statistical parametric mapping. Results: Pose estimation methods differed in their ability to measure kinematics. OpenPose and Tensorflow MoveNet Thunder methods were most accurate for measuring hip kinematics, averaging 3.7 +/- 1.3 deg and 4.6 +/- 1.8 deg (mean & PLUSMN; std) over the entire gait cycle, respectively. OpenPose was most accurate when measuring knee kinematics, averaging 5.1 +/- 2.5 deg of error over the gait cycle. MoveNet Thunder and OpenPose had the lowest errors when measuring spatiotemporal gait parameters but were not statistically different from one another. Significance: The results indicate that OpenPose significantly outperforms other existing platforms for pose -estimation of healthy gait kinematics and spatiotemporal gait parameters and could serve as an alternative to conventional motion capture systems in clinical and research settings when marker-based systems are not available.
引用
收藏
页码:188 / 195
页数:8
相关论文
共 50 条
  • [41] An Open-Source Wearable Sensor System for Measuring the Duty Factor of Runners
    Lee, Huang-Chen
    Wang, Soun-Cheng
    Lin, Zih-Hua
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [42] Methods and open-source toolkit for analyzing and visualizing challenge results
    Wiesenfarth, Manuel
    Reinke, Annika
    Landman, Bennett A.
    Eisenmann, Matthias
    Saiz, Laura Aguilera
    Cardoso, M. Jorge
    Maier-Hein, Lena
    Kopp-Schneider, Annette
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [43] Methods and open-source toolkit for analyzing and visualizing challenge results
    Manuel Wiesenfarth
    Annika Reinke
    Bennett A. Landman
    Matthias Eisenmann
    Laura Aguilera Saiz
    M. Jorge Cardoso
    Lena Maier-Hein
    Annette Kopp-Schneider
    Scientific Reports, 11 (1)
  • [44] Open-Source Sequence Clustering Methods Improve the State Of the Art
    Kopylova, Evguenia
    Navas-Molina, Jose A.
    Mercier, Celine
    Xu, Zhenjiang Zech
    Mahe, Frederic
    He, Yan
    Zhou, Hong-Wei
    Rognes, Torbjorn
    Caporaso, J. Gregory
    Knight, Rob
    MSYSTEMS, 2016, 1 (01)
  • [45] SPIS Open-Source Code: Methods, Capabilities, Achievements, and Prospects
    Roussel, Jean-Francois
    Rogier, Francois
    Dufour, Guillaume
    Mateo-Velez, Jean-Charles
    Forest, Julien
    Hilgers, Alain
    Rodgers, David
    Girard, Laurence
    Payan, Denis
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2008, 36 (05) : 2360 - 2368
  • [46] Comparing the Accuracy of Several Field Methods for Measuring Gully Erosion
    Castillo, C.
    Perez, R.
    James, M. R.
    Quinton, J. N.
    Taguas, E. V.
    Gomez, J. A.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2012, 76 (04) : 1319 - 1332
  • [47] Synthetic data generation methods in healthcare: A review on open-source tools and methods
    Pezoulas, Vasileios C.
    Zaridis, Dimitrios I.
    Mylona, Eugenia
    Androutsos, Christos
    Apostolidis, Kosmas
    Tachos, Nikolaos S.
    Fotiadis, Dimitrios I.
    COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2024, 23 : 2892 - 2910
  • [48] TRAC-IK: An Open-Source Library for Improved Solving of Generic Inverse Kinematics
    Beeson, Patrick
    Ames, Barrett
    2015 IEEE-RAS 15TH INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS (HUMANOIDS), 2015, : 928 - 935
  • [49] Reaching Kinematics in Movement Disorder Patients Using an Open-Source Computer Vision Technology
    Bayen, A. B.
    Majumdar, S.
    Choudhury, S.
    Ganguly, J.
    Basu, P.
    Dey, S.
    Baker, M.
    Baker, S.
    Kumar, H.
    MOVEMENT DISORDERS, 2024, 39 : S437 - S438
  • [50] Comparing commercial IP reputation databases to open-source IP reputation algorithms
    Academic and Research Network of Slovenia, p.p.7, 1000 Ljubljana, Slovenia
    不详
    Comput Syst Sci Eng, 1 (53-66):