11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism

被引:18
|
作者
Braeuning, U. [1 ]
Pfannenberg, C. [2 ]
Gallwitz, B. [3 ]
Teichmann, R. [4 ]
Mueller, M. [1 ]
Dittmann, H. [1 ]
Reimold, M. [1 ]
Bares, R. [1 ]
机构
[1] Univ Hosp Tuebingen, Dept Nucl Med, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Univ Hosp Tuebingen, Dept Internal Med, D-72076 Tubingen, Germany
[4] Univ Hosp Tuebingen, Dept Surg, D-72076 Tubingen, Germany
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2015年 / 54卷 / 01期
关键词
C-11-methionine-PET/CT; Tc-99m-MIBI-SPECT/CT; primary hyperparathyreoidism; PREOPERATIVE LOCALIZATION; C-11; METHIONINE;
D O I
10.3413/Nukmed-0686-14-07
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To investigate the efficacy of PET/CT with C-11-methionine for localizing parathyroid adenomas in patients with suspected primary hyperparathyroidism and inconclusive results of cervical ultrasonography and Tc-99m-MIBI-SPECT/CT. Patients, method: Retrospective analysis of imaging data of 18 patients and correlation with clinical outcome, in particular intraoperative findings and histopathology of excised tissue. Results: 12 of 18 patients received surgery. In 10 patients single parathyroid adenomas were found (diameter: 5-20 mm), 2 patients presented parathyroid hyperplasia (5 excised hyperplastic glands (diameter: 2-12 mm). PET/CT correctly localized all adenomas and 1 of 5 hyperplastic glands. The sensitivity per patient was 91.7% (11 of 12), the sensitivity per lesion 73.3% (11 of 15). All lesions missed by; PET/CT had a size smaller than 9 mm and a volume of less than 0.2 ml. In 6 patients no surgery was performed. Five of them had a negative or atypical PET/CT. Further follow-up indicated familial hypocalciuric hypercalcemia in 3 of them (thus, PET/CT true negative), in the remaining 2 patients no validation is available. One patient with 2 highly suggestive lesions rejected surgery so far. Conclusion: PET/CT with C-11-methionine is a very sensitive method for the detection of parathyroid adenomas, even if they are too small to be visualized by Tc-99m-MIBI-SPECT/CT.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 50 条
  • [41] Use of co-registered 11C-methionine PET and computed tomography for the localisation of parathyroid adenomas
    Beggs, AD
    Hain, SF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (11) : 1602 - 1602
  • [42] Use of co-registered 11C-methionine PET and computed tomography for the localisation of parathyroid adenomas
    Andrew D. Beggs
    Sharon F. Hain
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 1602 - 1602
  • [43] 18F-fluorocholine PET/CT imaging in primary hyperparathyroidism after negative or inconclusive cervical ultrasonography and 99mTc-MIBI scintigraphy
    Nemir, Eva Pasini
    Fares, Sara
    Rogic, Ivan
    Golubic, Anja Tea
    Huic, Drazen
    JAPANESE JOURNAL OF RADIOLOGY, 2024, : 687 - 695
  • [44] Diagnostic Utility of 11C-Methionine PET/CT in Primary Hyperparathyroidism for Localizing Parathyroid Adenomas in a Large UK Cohort: a Single-Center Experience and Literature Review
    Huynh, Kevin A.
    MacFarlane, James
    Newman, Christine
    Gillett, Daniel
    Das, Tilak
    Cheow, Heok
    Moyle, Penelope
    Koulouri, Olympia
    Powlson, Andrew
    Challis, Ben G.
    Bashari, Waiel A.
    Stokes, Victoria
    Masterson, Liam
    Jani, Piyush
    Fish, Brian
    Gurnell, Mark
    Casey, Ruth T.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 : S173 - S174
  • [45] Preoperative Localization of Adenomas in Primary Hyperparathyroidism: The Value of 11C-Choline PET/CT in Patients with Negative or Discordant Findings on Ultrasonography and 99mTc-Sestamibi SPECT/CT
    Liu, Yimin
    Dang, Yonghong
    Huo, Li
    Hu, Ya
    Wang, Ou
    Liu, He
    Chang, Xiaoyan
    Liu, Yu
    Xing, Xiaoping
    Li, Fang
    Liao, Quan
    Hacker, Marcus
    Li, Xiang
    Kreissl, Michael C.
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (04) : 584 - 589
  • [46] Localization of parathyroid adenomas with C11-methionine PET-CT
    Weber, T.
    Luster, M.
    CHIRURG, 2014, 85 (07): : 601 - 606
  • [47] Value of [ 11 C]-Methionine PET/CT in Preoperative Localization of Parathyroid Adenomas
    Saerens, Julie
    Velkeniers, Brigitte
    Keyaerts, Marleen
    Raeymaeckers, Steven
    Vanhoeij, Marian
    Blotwijk, Susanne
    Bravenboer, Bert
    HORMONE AND METABOLIC RESEARCH, 2021, 53 (07) : 444 - 452
  • [48] The utility of 99mTc-sestamibi scintigraphy in the localisation of parathyroid adenomas in primary hyperparathyroidism
    Glynn, N.
    Lynn, N.
    Donagh, C.
    Crowley, R. K.
    Smith, D.
    Thompson, C. J.
    Hill, A. D. K.
    Keeling, F.
    Agha, A.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 (01) : 191 - 194
  • [49] The utility of 99mTc-sestamibi scintigraphy in the localisation of parathyroid adenomas in primary hyperparathyroidism
    N. Glynn
    N. Lynn
    C. Donagh
    R. K. Crowley
    D. Smith
    C. J. Thompson
    A. D. K. Hill
    F. Keeling
    A. Agha
    Irish Journal of Medical Science, 2011, 180 : 191 - 194
  • [50] 11C-methionine PET versus 99mTc-sestamibi in the pre-operative localisation of hyperfunctional parathyroid tissue -: Reply
    Boerner, AR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (04) : 515 - 515