11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism

被引:18
|
作者
Braeuning, U. [1 ]
Pfannenberg, C. [2 ]
Gallwitz, B. [3 ]
Teichmann, R. [4 ]
Mueller, M. [1 ]
Dittmann, H. [1 ]
Reimold, M. [1 ]
Bares, R. [1 ]
机构
[1] Univ Hosp Tuebingen, Dept Nucl Med, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Univ Hosp Tuebingen, Dept Internal Med, D-72076 Tubingen, Germany
[4] Univ Hosp Tuebingen, Dept Surg, D-72076 Tubingen, Germany
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2015年 / 54卷 / 01期
关键词
C-11-methionine-PET/CT; Tc-99m-MIBI-SPECT/CT; primary hyperparathyreoidism; PREOPERATIVE LOCALIZATION; C-11; METHIONINE;
D O I
10.3413/Nukmed-0686-14-07
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To investigate the efficacy of PET/CT with C-11-methionine for localizing parathyroid adenomas in patients with suspected primary hyperparathyroidism and inconclusive results of cervical ultrasonography and Tc-99m-MIBI-SPECT/CT. Patients, method: Retrospective analysis of imaging data of 18 patients and correlation with clinical outcome, in particular intraoperative findings and histopathology of excised tissue. Results: 12 of 18 patients received surgery. In 10 patients single parathyroid adenomas were found (diameter: 5-20 mm), 2 patients presented parathyroid hyperplasia (5 excised hyperplastic glands (diameter: 2-12 mm). PET/CT correctly localized all adenomas and 1 of 5 hyperplastic glands. The sensitivity per patient was 91.7% (11 of 12), the sensitivity per lesion 73.3% (11 of 15). All lesions missed by; PET/CT had a size smaller than 9 mm and a volume of less than 0.2 ml. In 6 patients no surgery was performed. Five of them had a negative or atypical PET/CT. Further follow-up indicated familial hypocalciuric hypercalcemia in 3 of them (thus, PET/CT true negative), in the remaining 2 patients no validation is available. One patient with 2 highly suggestive lesions rejected surgery so far. Conclusion: PET/CT with C-11-methionine is a very sensitive method for the detection of parathyroid adenomas, even if they are too small to be visualized by Tc-99m-MIBI-SPECT/CT.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 50 条
  • [31] Tc-99m-MIBI-Negative Parathyroid Adenoma in Primary Hyperparathyroidism Detected by C-11-Methionine PET/CT After Previous Thyroid Surgery
    Schmidt, Matthias C.
    Kahraman, Deniz
    Neumaier, Bernd
    Ortmann, Monika
    Stippel, Dirk
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (12) : 1153 - 1155
  • [32] Positive 99mTc-MIBI SPECT/CT fusion imaging are related to biochemical and parathyroid volume in primary hyperparathyroidism
    Wang, Yuhua
    An, Caixia
    Zhang, Wanchun
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 178 - 178
  • [33] The Efficacy of 18F Choline PET/CT in comparison to Tc99m MIBI SPECT/CT in the Localisation of Hyperfunctioning Parathyroid Gland in primary Hyperparathyroidism
    Araz, M.
    Soydal, C.
    Ozkan, E.
    Kir, M.
    Ibis, E.
    Gullu, S.
    Erdogan, M. F.
    Emral, R.
    Kucuk, O. N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S89 - S90
  • [34] Parathyroid scintigraphy in patients with primary hyperparathyroidism:: 99mTc sestamibi SPECT and SPECT/CT
    Eslamy, Hedieh K.
    Ziessman, Harvey A.
    RADIOGRAPHICS, 2008, 28 (05) : 1461 - 1476
  • [35] 18F-Fluorocholine PET/CT Is More Sensitive Than 11C-Methionine PET/CT for the Localization of Hyperfunctioning Parathyroid Tissue in Primary Hyperparathyroidism
    Mathey, Celine
    Keyzer, Caroline
    Blocklet, Didier
    Van Simaeys, Gaetan
    Trotta, Nicola
    Lacroix, Simon
    Corvilain, Bernard
    Goldman, Serge
    Moreno-Reyes, Rodrigo
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (05) : 785 - 791
  • [36] Pre-Operative Localization with 11C-Methionine PET/CT and 99mTc-sestamibi in patients with confirmed parathyroid adenoma
    Martinez-Amador, N.
    Martinez-Rodriguez, I.
    De Arcocha-Torres, M.
    Banzo, I.
    Quirce, R.
    Jimenez-Bonilla, J.
    Ortega-Nava, F.
    Ibanez-Bravo, S.
    Bravo-Ferrer, Z.
    Lavado-Perez, C.
    Carril, J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S172 - S172
  • [37] 11C-methionine PET versus 99mTc-sestamibi in the pre-operative localisation of hyperfunctional parathyroid tissue
    Theodoros Athanasoulis
    European Journal of Nuclear Medicine and Molecular Imaging, 2005, 32 : 514 - 514
  • [38] 11C-Methionine PET/CT in Meningioma
    M. V. Galkin
    N. B. Vikhrova
    A. V. Golanov
    G. V. Danilov
    Yu. V. Strunina
    Neuroscience and Behavioral Physiology, 2024, 54 (6) : 894 - 899
  • [39] 11C-methionine PET versus 99mTc-sestamibi in the pre-operative localisation of hyperfunctional parathyroid tissue
    Athanasoulis, T
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (04) : 514 - 514
  • [40] Evaluating the diagnostic efficacy of 99mTc-methionine SPECT-CT in a comparison with 11C-methionine PET-MRI in glioma patients
    Kumar, Pardeep
    Kumar, Aishwarya
    Nagaraj, Chandana
    Saini, Jitender
    Mangalore, Sandhya
    Sadashiva, Nishanth
    Rajan, Archith
    Sitani, Keerti
    Hazari, Puja Panwar
    Mishra, Anil K.
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64