Near Fatal Ventricular Fibrillation in Brugada Syndrome Despite Presence of an Implanted Implantable Cardioverter Defibrillator

被引:14
|
作者
Belhassen, Bernard [1 ]
Viskin, Sami
机构
[1] Tel Aviv Sourasky Med Ctr, Dept Cardiol, IL-64239 Tel Aviv, Israel
关键词
D O I
10.1016/j.cjca.2014.06.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 38-year-old man with Brugada syndrome and aborted cardiac arrest was treated with quinidine only, based on the results of electrophysiologic drug testing. Six months later, after suffering a vaso-vagal syncope, he opted to receive an implantable cardioverter defibrillator and decided to discontinue quinidine against our recommendation. Sixty-seven months later, he had recurrent ventricular fibrillation that was terminated only by the sixth maximal energy shock delivered by the device (which has the capability to deliver a maximum of 8 shocks). This case suggests the possible risk in only relying on an implantable cardioverter defibrillator in the management of cardiac arrest survivors with Brugada syndrome.
引用
收藏
页码:1460.e3 / 1460.e5
页数:3
相关论文
共 50 条
  • [31] The variability of the electrocardiogram in Brugada syndrome: Implications for subcutaneous implantable cardioverter-defibrillator candidacy
    Brugada, Pedro
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (01) : 39 - 40
  • [32] Implantable Cardioverter Defibrillator Shock Embolizes an Atrial Septal Occluder Device in Brugada Syndrome
    Kothandam Sivakumar
    Sreeja Pavithran
    Amal Louis
    Radhakrishnan Satish
    Pediatric Cardiology, 2013, 34 : 1886 - 1889
  • [33] Failure to detect ventricular fibrillation in a patient with an implantable cardioverter-defibrillator [3]
    Antolinos-Pérez, María J.
    García-Alberola, Arcadio
    Redondo-Bermejo, Belén
    Valdés-Chávarri, Mariano
    Technische Uberwachung, 2006, 47 (06): : 517 - 518
  • [34] The implantable cardioverter defibrillator prolongs survival in ventricular fibrillation patients who are revascularized
    Link, MS
    Cesarz, CA
    Costeas, XF
    Estes, NAM
    Wang, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 37126 - 37126
  • [35] Reproducibility of ventricular fibrillation characteristics in patients undergoing implantable cardioverter defibrillator implantation
    Taneja, T
    Goldberger, J
    Parker, MA
    Johnson, D
    Robinson, N
    Horvath, G
    Kadish, AH
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (11) : 1209 - 1217
  • [36] SHOCK DELIVERED BY AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN RESPONSE TO SPONTANEOUS VENTRICULAR FIBRILLATION
    ROELKE, M
    ONUNAIN, SS
    NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (13): : 860 - 860
  • [37] Long-term prognosis of patients with Brugada syndrome and an implanted cardioverter-defibrillator
    Dores, Helder
    Santos, Katya Reis
    Adragao, Pedro
    Costa, Francisco Moscoso
    Santos, Pedro Galvao
    Carmo, Pedro
    Cavaco, Diogo
    Morgado, Francisco Bello
    Mendes, Miguel
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2015, 34 (06) : 394 - 401
  • [38] Mode of spontaneous onset of ventricular fibrillation in patients with idiopathic ventricular fibrillation detected by implantable cardioverter defibrillator therapy
    Kakishita, M
    Kurita, T
    Matsuo, K
    Taguchi, A
    Suyama, K
    Aihara, N
    Kamakura, S
    Yamamoto, F
    Kobayashi, J
    CIRCULATION, 1998, 98 (17) : 289 - 289
  • [39] Efficacy and limitations of treatment of ventricular fibrillation/ventricular tachycardia storm by subcutaneous implantable cardioverter defibrillator
    Nagra, Bipinpreet
    Awan, Muhammad Umer
    Miriyala, Varun
    Kantharia, Bharat K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 978 - 979
  • [40] TREATMENT OF VENTRICULAR TACHYARRHYTHMIAS WITH AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    FROHNER, K
    KALTENBRUNNER, W
    LAUFER, G
    LACZKOVICS, A
    WOLNER, E
    STEINBACH, K
    WIENER KLINISCHE WOCHENSCHRIFT, 1988, 100 (06) : 167 - 173