Experimental evaluation of heat transfer performance of falling film evaporator for wastewater source heat pump with backwash system

被引:4
|
作者
Zhang, Qunli [1 ,2 ]
Zhang, Xinchao [1 ,2 ]
Yin, Chaohui [3 ]
Liu, Fang [1 ,2 ]
Wang, Gang [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing Adv Innovat Ctr Future Urban Design, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing Key Lab Heating Gas Supply Ventilating &, Beijing 100044, Peoples R China
[3] China Mobile Grp Design Inst Co Ltd, Beijing 100044, Peoples R China
关键词
Direct wastewater source heat pump; Falling film evaporator; Flooded evaporator; Heat transfer coefficient; Scale removal; HORIZONTAL TUBES; SEWAGE; COEFFICIENTS; EXCHANGER; BUNDLE; ARRAYS; R-134A;
D O I
10.1016/j.ijrefrig.2020.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Urban wastewater contains large amounts of waste heat and the wastewater source heat pump (WWSHP) offers an effective way to use this heat. Increasing the overall heat transfer coefficient (OHTC) of the evaporator is an effective mean to improve the performance of the heat pump. In this work, falling film evaporator(FFE) is used in direct WWSHP. A WWSHP unit that can switch evaporators is first established. The effects of practical application of this WWSHP are then tested and compared with simulation results. Under the test conditions, the average OHTC of the wastewater FFE (WFFE) reaches 1960.90 W m(-2) K-1, while the average OHTC of a wastewater flooded evaporator (WFE) 1224.28 W m(-2) K-1. The average OHTC of the WFFE was thus 60.17% higher than that of the WFE and COP of the WFFE is 9.52% higher than that of the WFE. The experiment also explores the wastewater backwash, which can ensure stable operation of the unit. When using the backwash mode, the backwash time interval was set to be as short as possible to ensure that the average OHTC would not decrease. A mathematical model of the OHTC of the WFFE is presented. Using the wastewater condition as a basis, the mathematical model is used to synthetically calculate the shell side HTC of the WFFE, the convection HTC of the wastewater and the heat resistance of the tube walls and the fouling. From the experimental results, an influence factor for the wastewater down-and-up mode is proposed to revise the formula. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:80 / 93
页数:14
相关论文
共 50 条
  • [21] Experimental research on characteristics of the heat storage-evaporator in the air source heat pump system
    Wen, Bo
    Ma, Suxia
    Jiang, Yongming
    Zhang, Yaqi
    Zhang, Zijing
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2015, 36 (04): : 922 - 927
  • [22] Heat Transfer Performance of Vertical Tube Falling Film Juice Evaporator and a Sensitivity Analysis
    Song, Jitian
    Su, Hang
    Tian, Wei
    Wang, Yening
    Feng, Yongxia
    Liu, Jianbo
    INTERNATIONAL JOURNAL OF FOOD ENGINEERING, 2019, 15 (11-12)
  • [23] Experimental and theory investigations on falling film flow characteristics and heat extraction performance of spray heat exchanger for sewage heat pump system
    Na, W.
    Zeng, J. W.
    Li, D. Y.
    Wu, Y.
    Wu, J. S.
    SUSTAINABLE CITIES AND SOCIETY, 2020, 52
  • [24] Heat and mass transfer of ammonia-water in falling film evaporator
    Bu X.
    Ma W.
    Li H.
    Frontiers in Energy, 2011, 5 (4) : 358 - 366
  • [25] An experimental and numerical study of a de-fouling evaporator used in a wastewater source heat pump
    Shen, Chao
    Yang, Liangcheng
    Wang, Xinlei
    Jiang, Yiqiang
    Yao, Yang
    APPLIED THERMAL ENGINEERING, 2014, 70 (01) : 501 - 509
  • [26] Improved Heat Transfer Performance of Falling Film Evaporator for Desalination Industry by Balanced Liquid Distribution
    Cao, Chuanpeng
    Xie, Lixin
    Xu, Shichang
    Liu, Qian
    Du, Yawei
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (46) : 20492 - 20503
  • [27] STUDIES ON THE HEAT AND MASS TRANSFER PERFORMANCE OF THE NEW SOLAR LIBR FALLING FILM ABSORBER AND EVAPORATOR
    Gu Yaxiu
    Wu Yuyuan
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 3633 - +
  • [28] NONAZEOTROPIC MIXTURES AS WORKING FLUIDS IN LARGE HEAT PUMPS - HEAT TRANSFER IN A FALLING FILM EVAPORATOR AND SYSTEM SIMULATIONS.
    Berntsson, Karen Munch
    Chalmers Tekniska Hogskola, Doktorsavhandlingar, 1986, (563):
  • [29] Effect of cooling water flow on heat transfer performance of horizontal tube spray falling film evaporator in ORC system
    Hu, Bing
    Guo, Jiajun
    ENERGY REPORTS, 2022, 8 : 540 - 545
  • [30] Distribution of heat transfer coefficient in the vertical tube of falling film evaporator treating saline wastewater based on micro flow and experimental verification
    Bing, Liu
    Youle, Liu
    Chuan, Chen
    Jianliang, Xue
    Huashan, Li
    Zhun, Ma
    WATER REUSE, 2021, 11 (03) : 439 - 452