Experimental evaluation of heat transfer performance of falling film evaporator for wastewater source heat pump with backwash system

被引:4
|
作者
Zhang, Qunli [1 ,2 ]
Zhang, Xinchao [1 ,2 ]
Yin, Chaohui [3 ]
Liu, Fang [1 ,2 ]
Wang, Gang [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing Adv Innovat Ctr Future Urban Design, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing Key Lab Heating Gas Supply Ventilating &, Beijing 100044, Peoples R China
[3] China Mobile Grp Design Inst Co Ltd, Beijing 100044, Peoples R China
关键词
Direct wastewater source heat pump; Falling film evaporator; Flooded evaporator; Heat transfer coefficient; Scale removal; HORIZONTAL TUBES; SEWAGE; COEFFICIENTS; EXCHANGER; BUNDLE; ARRAYS; R-134A;
D O I
10.1016/j.ijrefrig.2020.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Urban wastewater contains large amounts of waste heat and the wastewater source heat pump (WWSHP) offers an effective way to use this heat. Increasing the overall heat transfer coefficient (OHTC) of the evaporator is an effective mean to improve the performance of the heat pump. In this work, falling film evaporator(FFE) is used in direct WWSHP. A WWSHP unit that can switch evaporators is first established. The effects of practical application of this WWSHP are then tested and compared with simulation results. Under the test conditions, the average OHTC of the wastewater FFE (WFFE) reaches 1960.90 W m(-2) K-1, while the average OHTC of a wastewater flooded evaporator (WFE) 1224.28 W m(-2) K-1. The average OHTC of the WFFE was thus 60.17% higher than that of the WFE and COP of the WFFE is 9.52% higher than that of the WFE. The experiment also explores the wastewater backwash, which can ensure stable operation of the unit. When using the backwash mode, the backwash time interval was set to be as short as possible to ensure that the average OHTC would not decrease. A mathematical model of the OHTC of the WFFE is presented. Using the wastewater condition as a basis, the mathematical model is used to synthetically calculate the shell side HTC of the WFFE, the convection HTC of the wastewater and the heat resistance of the tube walls and the fouling. From the experimental results, an influence factor for the wastewater down-and-up mode is proposed to revise the formula. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:80 / 93
页数:14
相关论文
共 50 条
  • [1] Experimental test on heating performance of backwash falling film sewage source heat pump unit
    Zhang Q.
    Yang Y.
    Zhang X.
    Liu F.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2022, 41 (05): : 2698 - 2705
  • [2] Experimental study of heat transfer performance of horizontal-tube falling film evaporator
    Li, Qingsheng
    Shen, Yongze
    Lai, Shengwang
    DESALINATION AND WATER TREATMENT, 2021, 218 : 87 - 96
  • [3] Experimental study on heat transfer performance of the umbrella-plate falling film evaporator
    Zhang, Li-Qiang
    Yang, Chun-Guang
    Xu, Lie
    Cai, Jiang
    Zhao, Jing-Li
    Huaxue Gongcheng/Chemical Engineering (China), 2006, 34 (06): : 17 - 20
  • [4] HEAT TRANSFER IN AN LTV FALLING FILM EVAPORATOR - A THEORETICAL AND EXPERIMENTAL ANALYSIS
    KROLL, JE
    MCCUTCHA.JW
    JOURNAL OF HEAT TRANSFER, 1968, 90 (02): : 201 - &
  • [5] HEAT TRANSFER IN AN LTV FALLING FILM EVAPORATOR - A THEORETICAL AND EXPERIMENTAL ANALYSIS
    KROLL, JE
    MCCUTCHA.JW
    MECHANICAL ENGINEERING, 1967, 89 (10) : 75 - &
  • [6] Experimental study on the heat transfer characteristics in falling liquid film evaporator
    Shi, Mingheng
    Prichard, C.
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 1997, 18 (01): : 77 - 80
  • [7] Experimental performance evaluation of a novel dry-expansion evaporator with defouling function in a wastewater source heat pump
    Shen Chao
    Jiang Yiqiang
    Yao Yang
    Deng Shiming
    APPLIED ENERGY, 2012, 95 : 202 - 209
  • [8] Modeling and simulation of a falling film evaporator for a water vapor heat pump system
    Hu, Bin
    Yan, Hongzhi
    Wang, R. Z.
    APPLIED ENERGY, 2019, 255
  • [9] Experimental exergoeconomic performance assessment of a wastewater source heat pump system
    Araz, Mustafa
    Hepbasli, Arif
    Gunerhan, Huseyin
    INTERNATIONAL JOURNAL OF EXERGY, 2019, 30 (03) : 239 - 258
  • [10] Theoretical and Experimental Study of Superhydrophobic Frost Suppression Heat Transfer Performance of Evaporator for Air Source Heat Pump
    Gu, Yaxiu
    Xing, Qingqing
    Li, Shuaipeng
    Han, Yi
    Li, Yaqi
    He, Guixiang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (05): : 1395 - 1404