Layer-by-layer chitosan-decorated pristine graphene on screen-printed electrodes by one-step electrodeposition for non-enzymatic hydrogen peroxide sensor

被引:18
|
作者
Zhu, Qin [1 ]
Liang, Bo [1 ]
Cai, Yu [1 ]
Cao, Qingpeng [1 ]
Tu, Tingting [1 ]
Huang, Bobo [1 ]
Fang, Lu [2 ]
Ye, Xuesong [1 ]
机构
[1] Zhejiang Univ, Innovat Ctr Minimally Invas Tech & Device, Coll Biomed Engn & Instrument Sci, Biosensor Natl Special Lab,Minist Educ,Key Lab Bi, Hangzhou 310027, Zhejiang, Peoples R China
[2] Hangzhou Dianzi Univ, Coll Life Informat Sci & Instrument Engn, Hangzhou 310018, Zhejiang, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Pristine graphene; Chitosan; Co-electrodeposition; Hydrogen peroxide biosensor; Screen-printed electrodes; OXIDE; REDUCTION; FUNCTIONALIZATION; NANOPARTICLES; FILMS;
D O I
10.1016/j.talanta.2018.07.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Layer-by-layer chitosan-decorated pristine graphene on screen-printed electrodes was achieved by one-step electrodeposition method and an enzyme-free hydrogen peroxide electrochemical biosensor was fabricated for its application. Negatively charged pristine graphene absorbed with positively charged chitosan by electrostatic interactions was electrodeposited on the electrodes. The successful immobilization of pristine graphene was confirmed by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and electrochemical characterizations. The graphene-chitosan volume ratio and cyclic voltammetry scan cycles during the electrodeposition process were optimized. The resulting hydrogen peroxide biosensors showed a 178 times improved sensitivity and exhibited two wide linear detection ranges from 20 mu M to 20 mM and from 20 mM to 60 mM. The biosensors also showed a good reproducibility, stability, selectivity and could be used in real samples detection. The superior electrochemical performance of graphene-chitosan was attributed to the preservation of excellent properties of pristine graphene, and the formation of layer-by-layer structure with high surface area. The proposed strategy of direct immobilization of pristine graphene can be extended for the immobilization of other nanomaterials and biomolecules.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [41] A Two-step Electrodeposition of Pd-Cu/Cu2O Nanocomposite on FTO Substrate for Non-enzymatic Hydrogen Peroxide Sensor
    Huan, Ke
    Tang, Li
    Deng, Dongmei
    Wang, Huan
    Si, Xiaojing
    Yan, Xiaoxia
    Luo, Liqiang
    [J]. CURRENT ANALYTICAL CHEMISTRY, 2021, 17 (09) : 1373 - 1381
  • [42] A novel non-enzymatic amperometric H2O2 sensor based on screen-printed electrode modified with reduced graphene oxide, polyneutralred and gold nanoparticles
    Kamac, Melike Bilgi
    Onat, Eda Kiymaz
    Yilmaz, Merve
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (04) : 408 - 418
  • [43] Experimental and theoretical study on one-step synthesis of AuAg alloy nanoparticle catalytic layer as highly stable non-enzymatic glucose sensing interface
    Zhao, Tongtong
    Li, Weiyin
    Shang, Ruiyong
    Lei, Yuxi
    Liu, Yaxing
    Ma, Chao
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2023, 950
  • [44] A Highly Sensitive Non-Enzymatic Urea Sensor Based on Ni(OH)2/Mn3O4/rGO/PANi Nanocomposites Using Screen-Printed Electrodes
    Maleki Nia, Saeid
    Kheiri, Farshad
    Jannatdoust, Elham
    Sirousazar, Mohammad
    Abbasi Chianeh, Vahid
    Kheiri, Golshad
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (06)
  • [45] 3D-copper oxide and copper oxide/few-layer graphene with screen printed nanosheet assembly for ultrasensitive non-enzymatic glucose sensing
    Zhang, Zhimei
    Pan, Peng
    Liu, Xuewen
    Yang, Zhengchun
    Wei, Jun
    Wei, Zhen
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2017, 187 : 28 - 38
  • [46] Silver Nanoparticles Formed Directly on a Screen-Printed Electrode/Graphene Oxide: A One-Step Electrochemical Synthesis and an Effective 2,4,6-Trichlorophenol Electrochemical Sensor
    Thi Tran, Luyen
    Tran, Hoang Vinh
    Dang, Trang Thi Hanh
    [J]. Journal of the Electrochemical Society, 2024, 171 (11)
  • [47] One-step coelectrodeposition-assisted layer-by-layer assembly of gold nanoparticles and reduced graphene oxide and its self-healing three-dimensional nanohybrid for an ultrasensitive DNA sensor
    Kumarasamy, Jayakumar
    Belen Camarada, Maria
    Venkatraman, Dharuman
    Ju, Huangxian
    Dey, Ramendra Sundar
    Wen, Yangping
    [J]. NANOSCALE, 2018, 10 (03) : 1196 - 1206
  • [48] Modification of bismuth film and poly(L-hydroxyproline) onto a screen-printed graphene electrode: A step towards a non-enzymatic platform for determining L-hydroxyproline in human urine samples
    Yomthiangthae, Phanumas
    del Valle, Manel
    Siangproh, Weena
    [J]. TALANTA, 2024, 267
  • [49] A highly sensitive non-enzymatic glucose sensor based on nickel and multi-walled carbon nanotubes nanohybrid films fabricated by one-step co-electrodeposition in ionic liquids
    Sun, Aili
    Zheng, Jianbin
    Sheng, Qinglin
    [J]. ELECTROCHIMICA ACTA, 2012, 65 : 64 - 69
  • [50] One-step construction of hierarchical Ni(OH)2/RGO/Cu2O on Cu foil for ultra-sensitive non-enzymatic glucose and hydrogen peroxide detection
    Wu, Xian
    Li, Fenglei
    Zhao, Chongjun
    Qian, Xiuzhen
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 274 : 163 - 171