One-step construction of hierarchical Ni(OH)2/RGO/Cu2O on Cu foil for ultra-sensitive non-enzymatic glucose and hydrogen peroxide detection

被引:49
|
作者
Wu, Xian [1 ]
Li, Fenglei [1 ]
Zhao, Chongjun [1 ]
Qian, Xiuzhen [1 ]
机构
[1] East China Univ Sci & Technol, Key Lab Ultrafine Mat, Minist Educ, Shanghai Key Lab Adv Polymer Mat,Sch Mat Sci & En, Shanghai 200237, Peoples R China
关键词
Ni(OH)(2)/RGO/Cu2O@Cu; Non-enzymatic biosensor; Glucose; Hydrogen peroxide; In-situ hydrothermal growth; Hierarchical; CHEMICAL BATH DEPOSITION; REDUCED GRAPHENE OXIDE; ONE-POT SYNTHESIS; ASSISTED SYNTHESIS; NANOWIRE ARRAYS; COPPER FOIL; PERFORMANCE; METAL; FILM; NANOCOMPOSITE;
D O I
10.1016/j.snb.2018.07.141
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hierarchized Ni(OH)(2)/RGO/Cu2O nanocomposite electrode grown on Cu foil was prepared through a facile in-situ one-pot hydrothermal method. Three kinds of strong interfaces of Ni(OH)(2)/RGO, RGO/Cu2O and Cu2O/Cu were simultaneously formed and thus a sandwich structure of Ni(OH)(2)/RGO/Cu2O was constructed on Cu substrate. Without further assembly and modification, as-synthesized Ni(OH)(2)/RGO/Cu2O@Cu was directly used as a non-enzymatic sensor, which exhibited a better amperometric response than other non-enzymatic sensors, e.g., detection limit (0.35 mu M and 0.20 mu M), sensitivity (5350 uA.mM(-1).cm(-2) and 1706.3 uA.mM(-1).cm(-2)) and linear range (0.5 mu M to 7.67 and 7.5 mM) on the detection of glucose and hydrogen peroxide. Furthermore, the non-enzymatic sensor showed good long-term stability and good performance in human blood analysis. The present work gives a new insight in sensor based on metal hydroxide/RGO/metal oxides electrode and its potential application in non-enzymatic glucose and hydrogen peroxide sensing.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 50 条
  • [1] Non-enzymatic electrochemical sensors for the detection of hydrogen peroxide based on Cu2O/Cu nanocomposites
    Luo, Binbin
    Li, Xueming
    Yang, Jianchun
    Li, Xianli
    Xue, Longping
    Li, Xiaolin
    Gu, Jiakun
    Wang, Mengzhen
    Jiang, Lu
    ANALYTICAL METHODS, 2014, 6 (04) : 1114 - 1120
  • [2] Non-enzymatic electrochemical sensor based on Cu2O/AuCu/Cu composite for hydrogen peroxide detection
    Liang, Xiaoyu
    Li, Weixiang
    Han, Hongliang
    Ma, Zhanfang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 834 : 43 - 48
  • [3] Cu2O ordered nanoarrays for non-enzymatic glucose detection
    Liu, Chenchen
    Xue, Kaifeng
    Sun, Aixin
    Chen, Dexiang
    Zhang, Pinhua
    Cui, Guangliang
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2021, 24 (06): : 829 - 835
  • [4] Nanostructured Cu2O deposited on TiO2 nanotube arrays for ultra-sensitive non-enzymatic glucose electrochemical biosensor
    Bittu Kumar
    Sudip Kumar Sinha
    Ionics, 2023, 29 : 793 - 805
  • [5] Nanostructured Cu2O deposited on TiO2 nanotube arrays for ultra-sensitive non-enzymatic glucose electrochemical biosensor
    Kumar, Bittu
    Sinha, Sudip Kumar
    IONICS, 2023, 29 (02) : 793 - 805
  • [6] Mesocrystalline Cu2O hollow nanocubes: synthesis and application in non-enzymatic amperometric detection of hydrogen peroxide and glucose
    Gao, Zhiyong
    Liu, Junli
    Chang, Jiuli
    Wu, Dapeng
    He, Jinjin
    Wang, Kui
    Xu, Fang
    Jiang, Kai
    CRYSTENGCOMM, 2012, 14 (20): : 6639 - 6646
  • [7] Graphene wrapped Cu2O nanocubes: Non-enzymatic electrochemical sensors for the detection of glucose and hydrogen peroxide with enhanced stability
    Liu, Minmin
    Liu, Ru
    Chen, Wei
    BIOSENSORS & BIOELECTRONICS, 2013, 45 : 206 - 212
  • [8] Hydrothermal deposition of CuO/rGO/Cu2O nanocomposite on copper foil for sensitive nonenzymatic voltammetric determination of glucose and hydrogen peroxide
    Chongjun Zhao
    Xian Wu
    Pengwei Li
    Chunhua Zhao
    Xiuzhen Qian
    Microchimica Acta, 2017, 184 : 2341 - 2348
  • [9] Hydrothermal deposition of CuO/rGO/Cu2O nanocomposite on copper foil for sensitive nonenzymatic voltammetric determination of glucose and hydrogen peroxide
    Zhao, Chongjun
    Wu, Xian
    Li, Pengwei
    Zhao, Chunhua
    Qian, Xiuzhen
    MICROCHIMICA ACTA, 2017, 184 (07) : 2341 - 2348
  • [10] Nanostructured Cu2O deposited on TiO2 nanotube arrays for ultra-sensitive non-enzymatic cholesterol electrochemical biosensor
    Kumar, Bittu
    Sinha, Sudip Kumar
    MATERIALS TODAY COMMUNICATIONS, 2023, 37