Calibration of AC Shunts at Frequencies up to 10 kHz Using Digital Sampling

被引:0
|
作者
Djokic, Branislav [1 ]
Parks, Harold [1 ]
机构
[1] Natl Res Council Canada, Measurement Sci & Stand, Ottawa, ON, Canada
关键词
AC shunt; current measurement; measurement standards; calibration; measurement uncertainty; currentcomparator; calculable resistor; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a calibration system for AC shunts using digital sampling. It provides both ratio errors and phase displacements of a shunt under test with respect to a reference shunt. In its basic configuration, the calibration system operates at currents of up to 10 A and frequencies of up to 10 kHz. The expanded uncertainties (k = 2) of the described calibration system are estimated to be better than 30 mu A/A for magnitude and 30 mu rad for phase at 10 kHz, and lower than these at lower frequencies.
引用
收藏
页数:2
相关论文
共 50 条
  • [41] PRECISION AC VOLTAGE MEASUREMENTS USING DIGITAL SAMPLING TECHNIQUES
    SWERLEIN, RL
    HEWLETT-PACKARD JOURNAL, 1989, 40 (02): : 15 - 21
  • [42] New impedance bridge at LNE for the two terminal-pair AC resistor calibration up to 20 kHz
    Ouameur, Mohamed
    Vasconcellos, Renata
    Agazar, Mohamed
    Thevenot, Olivier
    Patois, Emmanuel
    METROLOGIA, 2022, 59 (05)
  • [43] Calibration of Electronic Transformer Tester using Digital Sampling method
    Pan, Yang
    Shi, Leibing
    Feng, Jian
    Zhou, Liren
    Sun, Weibin
    Li, Ruoshi
    Zhang, Minghui
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [44] A new method to extend the current ranges from 10 mA to 100 A at frequencies up to 100 kHz
    Pan, Xianlin
    Zhang, Jiangtao
    Song, Ying
    Shi, Zhaomin
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [45] Primary calibration of hydrophones in the frequency range 10 to 500 kHz using a heterodyne interferometer
    Wang, Min
    Yang, Ping
    He, Longbiao
    Feng, Xiujuan
    Xing, Guangzhen
    Shengxue Xuebao/Acta Acustica, 2021, 46 (04): : 614 - 622
  • [46] A PRECISION CALIBRATION SET-UP FOR AC MAGNETIC FLUX DENSITY MEASUREMENT IN THE RANGE OF 1 Hz TO 20 kHz
    Park, Po Gyu
    Kim, Young Gyun
    Kim, Wan-Seop
    Kalabin, V. N.
    Shifrin, V. Ya.
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 780 - 782
  • [47] Application of MPC to an active structure using sampling rates up to 25kHz
    Wills, A.
    Bates, D.
    Fleming, A.
    Ninness, B.
    Moheimani, R.
    2005 44TH IEEE CONFERENCE ON DECISION AND CONTROL & EUROPEAN CONTROL CONFERENCE, VOLS 1-8, 2005, : 3176 - 3181
  • [48] Bridges for calibrating four-terminal-pair standards of self-inductance at frequencies up to 10 kHz
    Sedlacek, R.
    Bohacek, J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (02)
  • [49] Digital nonlinearity calibration for pipelined ADCs using sampling capacitors splitting
    Fan Chaojie
    Lu Yuxiao
    Wang Ke
    Zhou Jianjun
    IEICE ELECTRONICS EXPRESS, 2014, 11 (13):
  • [50] Calibration of Miniature Medical Ultrasonic Hydrophones for Frequencies in the Range 100 to 500 kHz Using an Ultrasonically Absorbing Waveguide
    Rajagopal, Srinath
    Zeqiri, Bajram
    Gelat, Pierre N.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (05) : 765 - 778