Selection Strategy of Jaw Tracking in VMAT Planning for Lung SBRT

被引:0
|
作者
Sun, Wuji [1 ]
Shi, Yinghua [1 ]
Li, Yu [1 ]
Ge, Chao [1 ]
Yang, Xu [1 ]
Xia, Wenming [1 ]
Chen, Kunzhi [1 ]
Wang, Libo [1 ]
Dong, Lihua [1 ,2 ,3 ]
Wang, Huidong [1 ,2 ]
机构
[1] First Hosp Jilin Univ, Dept Radiat Oncol & Therapy, Changchun, Peoples R China
[2] First Hosp Jilin Univ, Dept Radiat Oncol & Therapy, Jilin Prov Key Lab Radiat Oncol & Therapy, Changchun, Peoples R China
[3] Jilin Univ, Natl Hlth Commiss NHC Key Lab Radiobiol, Sch Publ Hlth, Changchun, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
关键词
stereotactic body radiation therapy; jaw tracking technique; volumetric modulated arc therapy; planning target volume; small field; BODY RADIATION-THERAPY; FILTER-FREE BEAMS; RESPIRATORY MOTION; RADIOTHERAPY; COMPLEXITY; IMPACT;
D O I
10.3389/fonc.2022.820632
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeThis study aimed to investigate the dosimetric effect and delivery reliability of jaw tracking (JT) with increasing planning target volume (PTV) for lung stereotactic body radiation therapy (SBRT) plans. A threshold of PTV was proposed as a selection criterion between JT and fixed-jaw (FJ) techniques. MethodsA total of 28 patients with early-stage non-small-cell lung cancer were retrospectively included. The PTVs ranged from 4.88 cc to 68.74 cc, prescribed with 48 Gy in four fractions. Three-partial-arc volumetric modulated arc therapy (VMAT) plans with FJ and with JT were created for each patient with the same optimization objectives. These two sets of plans were compared using metrics, including conformity index (CI), V-50%, R-50%, D-2cm, dose-volume parameters of organs at risk, and monitor units (MUs). The ratio of small subfields (<3 cm in either dimension), %SS, was acquired as a surrogate for the small-field uncertainty. Statistical analyses were performed to evaluate the correlation between the differences in these parameters and the PTV. ResultsThe V-50%, R-50%, D-2cm, and V-20Gy, D-1,D-500cc, and D-1,D-000cc of the lung showed a statistically significant improvement in JT plans as opposed to FJ plans, while the number of MU in JT plans was higher by an average of 1.9%. Between FJ and JT plans, the PTV was strongly correlated with the differences in V-50%, moderately correlated with those in V-20Gy of the lung, and weakly correlated with those in D-2cm and D-1,D-500cc of the lung. By using JT, %SS was found to be negatively correlated with the PTV, and the PTV should be at least approximately 12.5 cc for an expected %SS <50%, which was 15 cc for a %SS ConclusionsConsidering the dosimetric differences and small-field uncertainties, JT could be selected using a PTV threshold, such as 12.5, 15, or 20 cc, on the basis of the demand of delivery reliability for lung SBRT.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] VMAT VS. CONVENTIONAL IMRT TECHNIQUES FOR SBRT OF LUNG CANCER
    Holt, A.
    van Vliet-Vroegindeweij, C.
    Belderbos, J. S. A.
    Damen, E. M. F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S84 - S84
  • [42] Alternative VMAT Technique Reduces Total Monitor Units for Lung SBRT
    Happersett, L.
    Mechalakos, J.
    Kuo, L.
    Zhang, P.
    Rimner, A.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 228 - 228
  • [43] Comparing 4D-VMAT, gated-VMAT and 3D-VMAT in SBRT treatment of lung cancer
    Chin, E.
    Loewen, S.
    Nichol, A.
    Otto, K.
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4622 - 4622
  • [44] Biological consequences of dynamic dose interplay in VMAT SBRT lung treatments
    Sjolin, M.
    Elezaj, D.
    Ottosson, W.
    Edmund, J. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S830 - S830
  • [45] SBRT 4-Dimensional Treatment Planning for Vero Dynamic Tumor Tracking Lung Patients
    Su, Z.
    Dagan, R.
    Li, Z.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3494 - 3494
  • [46] Lung SBRT Using Helical Tomotherapy: Dosimetric and Delivery Comparison of Dynamic Jaw and Fixed Jaw
    Wu, J.
    Min, L.
    Shengwei, K.
    Pei, W.
    Jie, L.
    Bin, T.
    Orlandini, L. C.
    Fan, W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E258 - E258
  • [47] A novel lung SBRT treatment planning: Inverse VMAT plan with leaf motion limitation to ensure the irradiation reproducibility of a moving target
    Darreon, Julien
    Debnath, Sree Bash Chandra
    Benkreira, Mohamed
    Fau, Pierre
    Mailleux, Hugues
    Ferre, Marjorie
    Benkemouche, Ahcene
    Tallet, Agnes
    Annede, Pierre
    Petit, Claire
    Salem, Naji
    [J]. MEDICAL DOSIMETRY, 2024, 49 (02) : 159 - 164
  • [48] Static couch non-coplanar arc selection optimization for lung SBRT treatment planning
    Lincoln, John D.
    MacDonald, R. Lee
    Syme, Alasdair
    Thomas, Christopher G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (15):
  • [49] Optimal imaging conditions in the planning of dynamic tracking SBRT
    Takakura, T.
    Mukumoto, N.
    Higuchi, D.
    Ito, Y.
    Nakayasu, N.
    Ito, H.
    Sakamoto, T.
    [J]. EUROPEAN JOURNAL OF CANCER, 2015, 51 : S124 - S124
  • [50] Evaluation of a Scripted Planning Technique in Lung SBRT
    Donaghue, J.
    Gajdos, S.
    Mossolly, L. Muhieddine
    [J]. MEDICAL PHYSICS, 2021, 48 (06)