Selection Strategy of Jaw Tracking in VMAT Planning for Lung SBRT

被引:0
|
作者
Sun, Wuji [1 ]
Shi, Yinghua [1 ]
Li, Yu [1 ]
Ge, Chao [1 ]
Yang, Xu [1 ]
Xia, Wenming [1 ]
Chen, Kunzhi [1 ]
Wang, Libo [1 ]
Dong, Lihua [1 ,2 ,3 ]
Wang, Huidong [1 ,2 ]
机构
[1] First Hosp Jilin Univ, Dept Radiat Oncol & Therapy, Changchun, Peoples R China
[2] First Hosp Jilin Univ, Dept Radiat Oncol & Therapy, Jilin Prov Key Lab Radiat Oncol & Therapy, Changchun, Peoples R China
[3] Jilin Univ, Natl Hlth Commiss NHC Key Lab Radiobiol, Sch Publ Hlth, Changchun, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
关键词
stereotactic body radiation therapy; jaw tracking technique; volumetric modulated arc therapy; planning target volume; small field; BODY RADIATION-THERAPY; FILTER-FREE BEAMS; RESPIRATORY MOTION; RADIOTHERAPY; COMPLEXITY; IMPACT;
D O I
10.3389/fonc.2022.820632
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeThis study aimed to investigate the dosimetric effect and delivery reliability of jaw tracking (JT) with increasing planning target volume (PTV) for lung stereotactic body radiation therapy (SBRT) plans. A threshold of PTV was proposed as a selection criterion between JT and fixed-jaw (FJ) techniques. MethodsA total of 28 patients with early-stage non-small-cell lung cancer were retrospectively included. The PTVs ranged from 4.88 cc to 68.74 cc, prescribed with 48 Gy in four fractions. Three-partial-arc volumetric modulated arc therapy (VMAT) plans with FJ and with JT were created for each patient with the same optimization objectives. These two sets of plans were compared using metrics, including conformity index (CI), V-50%, R-50%, D-2cm, dose-volume parameters of organs at risk, and monitor units (MUs). The ratio of small subfields (<3 cm in either dimension), %SS, was acquired as a surrogate for the small-field uncertainty. Statistical analyses were performed to evaluate the correlation between the differences in these parameters and the PTV. ResultsThe V-50%, R-50%, D-2cm, and V-20Gy, D-1,D-500cc, and D-1,D-000cc of the lung showed a statistically significant improvement in JT plans as opposed to FJ plans, while the number of MU in JT plans was higher by an average of 1.9%. Between FJ and JT plans, the PTV was strongly correlated with the differences in V-50%, moderately correlated with those in V-20Gy of the lung, and weakly correlated with those in D-2cm and D-1,D-500cc of the lung. By using JT, %SS was found to be negatively correlated with the PTV, and the PTV should be at least approximately 12.5 cc for an expected %SS <50%, which was 15 cc for a %SS ConclusionsConsidering the dosimetric differences and small-field uncertainties, JT could be selected using a PTV threshold, such as 12.5, 15, or 20 cc, on the basis of the demand of delivery reliability for lung SBRT.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Dosimetric Influence of Jaw Tracking Option On Lung SBRT Using VMAT and IMRT Techniques
    Amoush, A.
    Ferjani, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3108 - 3108
  • [2] On the validity of density overrides for VMAT lung SBRT planning
    Wiant, David
    Vanderstraeten, Caroline
    Maurer, Jacqueline
    Pursley, Jan
    Terrell, Jonathon
    Sintay, Benjamin J.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 104 - 118
  • [3] Lung SBRT treatment planning: a study of VMAT arc selection guided by collision check software
    Hamilton, Tyrone
    Zhang, Jiahan
    Wolf, Jonathan
    Kayode, Oluwatosin
    Higgins, Kristin A.
    Bradley, Jeffrey
    Yang, Xiaofeng
    Schreibmann, Eduard
    Roper, Justin
    [J]. MEDICAL DOSIMETRY, 2023, 48 (02) : 82 - 89
  • [4] Robust Planning for ITV-Based Lung VMAT SBRT
    Peca, S.
    Buczek, A.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E946 - E947
  • [5] Potential reduction of lung dose via VMAT with jaw tracking in the treatment of single-isocenter/two-lesion lung SBRT
    Pokhrel, Damodar
    Sanford, Lana
    Halfman, Matthew
    Molloy, Janelle
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (05): : 55 - 63
  • [6] Four-Dimensional Treatment Planning for Lung VMAT-SBRT
    Hashimoto, M.
    Oohira, S.
    Ueda, Y.
    Miyazaki, M.
    Isono, M.
    Masaoka, A.
    Takashina, M.
    Koizumi, M.
    Teshima, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3434 - 3434
  • [7] A novel approach to automatic planning: robust templates for lung VMAT SBRT
    Marrazzo, L.
    Arilli, C.
    Calusi, S.
    Casati, M.
    Talamonti, C.
    Bonomo, P.
    Livi, L.
    Pallotta, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S496 - S497
  • [8] Investigation of Dose Calculation Accuracy in VMAT Planning for SBRT Lung Treatment
    Rao, M.
    Wu, J.
    Cao, D.
    Ye, J.
    Chen, F.
    Wong, T.
    Mehta, V.
    Shepard, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S774 - S774
  • [9] Evaluation and validation of density override in VMAT treatment planning for lung SBRT
    Ong, C. L.
    Franken, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S823 - S824
  • [10] Commissioning VMAT with Jaw Tracking in the Raystation Treatment Planning System for a Varian TrueBeam
    Pursley, J.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3111 - 3111