Evaluation of the integration of an ammonia-water power cycle in an absorption refrigeration system of an industrial plant

被引:36
|
作者
Higa, Marcio [1 ]
Yamamoto, Eduardo Y. [1 ]
de Oliveira, Julio Cesar D. [1 ]
Conceicao, Wagner Andre S. [1 ]
机构
[1] Univ Estadual Maringa, Dept Mech Engn, Av Colombo 5790,BL14, BR-87020900 Maringa, PR, Brazil
关键词
Kalina cycle; Ammonia-water absorption refrigeration system; Cogeneration; Exergy analysis; COMPREHENSIVE EXERGOECONOMIC ANALYSIS; ORGANIC RANKINE-CYCLE; KALINA CYCLE; THERMODYNAMIC ANALYSIS; EXERGY ANALYSIS; CASCADE UTILIZATION; COGENERATION CYCLE; WASTE HEAT; ENERGY; GENERATION;
D O I
10.1016/j.enconman.2018.10.041
中图分类号
O414.1 [热力学];
学科分类号
摘要
Combination of binary components used for absorption refrigeration systems as ammonia-water can also be applied as working mixture for power generation in a Kalina Cycle, providing an interesting option in the use of energy sources at low temperatures. Using this possibility in a power-cooling cogeneration system, Kalina Cycle (KC) was proposed to be integrated in an ammonia-water absorption refrigeration system (AARS) of 1269 kW of cooling at 219 K, in order to take better advantage of the available energy from a steam generator in an industrial plant, used as a case study. The AARS uses water steam as hot utility, after the expansion in a pressure reducing valve from higher pressure. Applying exergy analysis, it was verified that the combined KC-AARS, besides the power generation, can decrease the exergy destruction in the AARS. For that, due to the very low working temperatures, the AARS involving double absorbers and evaporators, condenser and expansion valves in a complex system and its peculiarities were practically preserved at lower pressure levels, integrating the KC basically in the higher pressure levels, which is a very interesting proposal for existent systems. The results showed the possibility to reduce the exergy destruction in 43.3%, from 1614 to 915.8 kW, and to produce 493 kW of power generation. In addition, increases in the coefficient of performance from 0.256 to 0.376, energy efficiency of refrigeration from 0.297 to 0.360 and exergy efficiency from 0.185 to 0.468 were reached at 4.7 MPa of working pressure.
引用
收藏
页码:265 / 276
页数:12
相关论文
共 50 条
  • [21] CONCURRENT, CROSSCURRENT, AND COUNTERCURRENT ABSORPTION IN AMMONIA-WATER ABSORPTION REFRIGERATION
    BRIGGS, SW
    ASHRAE JOURNAL, 1971, 13 (01): : 57 - &
  • [22] Performance analysis and evaluation of a triple-effect ammonia-water absorption-refrigeration system
    Ratlamwala, T. A. H.
    Dincer, I.
    Gadalla, M. A.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (05) : 475 - 483
  • [23] Performance assessment and optimization of a novel geothermal combined cooling and power system integrating an organic flash cycle with an ammonia-water absorption refrigeration cycle
    Wu, Chuang
    Xu, Xiaoxiao
    Li, Qibin
    Li, Xiaoxiao
    Liu, Lang
    Liu, Chao
    ENERGY CONVERSION AND MANAGEMENT, 2021, 227
  • [24] Ammonia-water absorption refrigeration systems with flooded evaporators
    Fernandez-Seara, Jose
    Sieres, Jaime
    APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) : 2236 - 2246
  • [25] THERMAL PERFORMANCE OF AN AMMONIA-WATER REFRIGERATION SYSTEM
    MANRIQUE, JA
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1991, 18 (06) : 779 - 789
  • [26] AN AUTONOMOUS SOLAR AMMONIA-WATER REFRIGERATION SYSTEM
    STAICOVICI, MD
    SOLAR ENERGY, 1986, 36 (02) : 115 - 124
  • [27] Simulation of an ammonia-water compression-absorption refrigeration system for water chilling application
    Pratihar, A. K.
    Kaushik, S. C.
    Agarwal, R. S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (07): : 1386 - 1394
  • [28] AN ENERGETIC AND EXERGOECONOMIC ANALYSIS OF A CCHP SYSTEM WITH MICRO GAS TURBINE, ORGANIC RANKINE CYCLE AND AMMONIA-WATER ABSORPTION REFRIGERATION CYCLE
    Doiphode, Ganesh V.
    Najafi, Hamidreza
    PROCEEDINGS OF THE ASME 13TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2019, 2019,
  • [29] Series connected ammonia-water refrigeration and power combined cycle and its sensitivity analysis
    Liu, Meng
    Zhang, Na
    Cai, Rui-Xian
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2006, 26 (01): : 1 - 7
  • [30] Yearly investigation of a solar-driven absorption refrigeration system with ammonia-water absorption pair
    Bellos, Evangelos
    Chatzovoulos, Ion
    Tzivanidis, Christos
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 23