A novel method to measure low flux ambient thermal neutrons with 3He proportional counters

被引:9
|
作者
Zeng, Z. M. [1 ,2 ]
Gong, H. [1 ,2 ]
Yue, Q. [1 ,2 ]
Li, J. M. [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Double-pulse effect; PSD; Underground laboratory; Low background neutron; He-3 proportional tube;
D O I
10.1016/j.nima.2017.04.009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A pulse shape discrimination method to discriminate neutron events from backgrounds based on the double-pulse effect of He-3 proportional counters is proposed and detailed in this paper. We made an ambient thermal neutron measurement system composed of a commercial He-3 proportional counter tube and the corresponding readout electronics. The background of the system has been measured and the minimum detectable amount of the He-3 proportional counter tube will be reduced by an order of magnitude with this method. The system was applied to measure the ambient thermal neutron flux inside a large neutron shielding structure at a deep underground laboratory and the pulse shape discrimination method proves to be effective. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 247
页数:6
相关论文
共 50 条
  • [21] LOW VOLTAGE HE3-FILLED PROPORTIONAL COUNTER FOR EFFICIENT DETECTION OF THERMAL AND EPITHERMAL NEUTRONS
    MILLS, WR
    CALDWELL, RL
    MORGAN, IL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (08): : 866 - &
  • [22] An experiment to measure the thermal conductivity of polarized liquid 3He
    Buu, O
    Puech, L
    Wolf, PE
    PHYSICA B, 2000, 284 (284): : 184 - 185
  • [23] Measurements of fast neutrons above ground and in 47 m depth with a 3He proportional counter
    S. Niese
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 272 : 173 - 176
  • [24] Measurements of fast neutrons above ground and in 47 m depth with a 3He proportional counter
    Niese, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 272 (01) : 173 - 176
  • [25] Simulation Response of He-3 Filled Proportional Counter for Thermal Neutrons
    Jamil, M.
    Rhee, J. T.
    Kim, H. G.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [26] Neutron flux and spectrum in the Dresden Felsenkeller underground facility studied by moderated 3He counters
    Grieger, M.
    Hensel, T.
    Agramunt, J.
    Bemmerer, D.
    Degering, D.
    Dillmann, I
    Fraile, L. M.
    Jordan, D.
    Koster, U.
    Marta, M.
    Mueller, S. E.
    Szuecs, T.
    Tain, J. L.
    Zuber, K.
    PHYSICAL REVIEW D, 2020, 101 (12)
  • [27] INFLUENCE OF DIRECTION OF CHARGED-PARTICLES PRODUCED BY THERMAL-NEUTRONS ON PULSE-HEIGHT IN HE-3 PROPORTIONAL-COUNTERS
    TAKEDA, N
    KUDO, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 548 - 551
  • [28] Independent measurement of the total active 8B solar neutrino flux using an array of 3He proportional counters at the sudbury neutrino observatory
    Aharmim, B.
    Ahmed, S. N.
    Amsbaugh, J. F.
    Anthony, A. E.
    Banar, J.
    Barros, N.
    Beier, E. W.
    Bellerive, A.
    Beltran, B.
    Bergevin, M.
    Biller, S. D.
    Boudjemline, K.
    Boulay, M. G.
    Bowles, T. J.
    Browne, M. C.
    Bullard, T. V.
    Burritt, T. H.
    Cai, B.
    Chan, Y. D.
    Chauhan, D.
    Chen, M.
    Cleveland, B. T.
    Cox-Mobrand, G. A.
    Currat, C. A.
    Dai, X.
    Deng, H.
    Detwiler, J.
    DiMarco, M.
    Doe, P. J.
    Doucas, G.
    Drouin, P. -L.
    Duba, C. A.
    Duncan, F. A.
    Dunford, M.
    Earle, E. D.
    Elliott, S. R.
    Evans, H. C.
    Ewan, G. T.
    Farine, J.
    Fergani, H.
    Fleurot, F.
    Ford, R. J.
    Formaggio, J. A.
    Fowler, M. M.
    Gagnon, N.
    Germani, J. V.
    Goldschmidt, A.
    Goon, J. T. M.
    Graham, K.
    Guillian, E.
    PHYSICAL REVIEW LETTERS, 2008, 101 (11)
  • [29] 3HE-NE-CH4 MIXTURES IN PROPORTIONAL COUNTER FOR THERMAL NEUTRONS
    KROHN, VE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (07): : 853 - &
  • [30] DEVELOPMENT OF POSITION-SENSITIVE HE-3 PROPORTIONAL COUNTER FOR THERMAL-NEUTRONS WITH NOVEL SIGNAL READOUT
    URITANI, A
    MORI, C
    WATANABE, T
    MIYAHARA, A
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1990, 27 (08) : 712 - 717