LOW VOLTAGE HE3-FILLED PROPORTIONAL COUNTER FOR EFFICIENT DETECTION OF THERMAL AND EPITHERMAL NEUTRONS

被引:24
|
作者
MILLS, WR
CALDWELL, RL
MORGAN, IL
机构
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1962年 / 33卷 / 08期
关键词
D O I
10.1063/1.1717994
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:866 / &
相关论文
共 35 条
  • [1] Simulation Response of He-3 Filled Proportional Counter for Thermal Neutrons
    Jamil, M.
    Rhee, J. T.
    Kim, H. G.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [2] 3HE-NE-CH4 MIXTURES IN PROPORTIONAL COUNTER FOR THERMAL NEUTRONS
    KROHN, VE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (07): : 853 - &
  • [3] SPHERICAL PROPORTIONAL COUNTER FILLED WITH HE-3
    KOROLEV, VI
    SAVINSKI.AK
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (01): : 71 - &
  • [4] DETECTION OF THERMAL NEUTRONS BY BORAZOLE FILLED PROPORTIONAL COUNTERS
    DEVRIES, AE
    HAMERS, HC
    BLOK, J
    JONKER, CC
    JANSZ, H
    KISTEMAKER, J
    PHYSICA, 1954, 20 (11): : 1138 - 1140
  • [5] High-efficiency 3He proportional counter for the detection of delayed neutrons
    Loaiza, DJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 43 - 46
  • [6] 3He proportional counter development for thermal neutron detection
    Fares, Mohamed
    Messai, Adnane
    Begaa, Samir
    Salem, Maameri
    Negara, Kassida
    Debili, Mohamed Yacine
    Messaoudi, Mohammed
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2021, 5 (02) : 264 - 272
  • [7] 3He proportional counter development for thermal neutron detection
    Mohamed Fares
    Adnane Messai
    Samir Begaa
    Maameri Salem
    Kassida Negara
    Mohamed Yacine Debili
    Mohammed Messaoudi
    Radiation Detection Technology and Methods, 2021, 5 : 264 - 272
  • [8] Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters
    Kudo, K
    Takeda, N
    Uritani, A
    Koshikawa, S
    Shibata, Y
    Kobayashi, K
    Yoshimoto, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 305 - 309
  • [9] LOW-LEVEL GAMMA AND NEUTRON MONITORING BASED ON USE OF PROPORTIONAL COUNTER FILLED WITH 3HE IN POLYTHENE MODERATOR: STUDY OF THE RESPONSES TO GAMMA AND NEUTRONS
    Pszona, S.
    Bantsar, A.
    Tulik, P.
    Wincel, K.
    Zareba, B.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 237 - 240
  • [10] DEVELOPMENT OF POSITION-SENSITIVE HE-3 PROPORTIONAL COUNTER FOR THERMAL-NEUTRONS WITH NOVEL SIGNAL READOUT
    URITANI, A
    MORI, C
    WATANABE, T
    MIYAHARA, A
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1990, 27 (08) : 712 - 717