Distal Stent Graft-Induced New Entry: An Emerging Complication of Endovascular Treatment in Aortic Dissection

被引:91
|
作者
Pantaleo, Antonio
Jafrancesco, Giuliano
Buia, Francesco
Leone, Alessandro
Lovato, Luigi
Russo, Vincenzo
Di Marco, Luca
Di Bartolomeo, Roberto
Pacini, Davide
机构
[1] Univ Bologna, S Orsola Malpighi Hosp, Dept Cardiac Surg, Bologna, Italy
[2] Univ Bologna, S Orsola Malpighi Hosp, Dept Radiol, Bologna, Italy
来源
ANNALS OF THORACIC SURGERY | 2016年 / 102卷 / 02期
关键词
STEEL-BASED DEVICE; THORACIC AORTA; B DISSECTION; REPAIR; FAILURE; MANAGEMENT; PLACEMENT; ARCH;
D O I
10.1016/j.athoracsur.2016.02.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Aortic dissection is a major cardiovascular disease associated with a high mortality rate. In complicated type B dissection, with favorable anatomy, endovascular surgical repair (thoracic endovascular aortic repair [TEVAR]) is considered the treatment of choice. Intimomedial injury induced by stent graft, or stent graft-induced new entry (SINE), has a clinically significant incidence. SINE can occur at the proximal or distal level of the stent graft. The aim of this retrospective study was to investigate the incidence, mechanism, and predictive factors of late distal SINE. Methods. We reviewed 139 discharged patients after TEVAR for type B or residual aortic dissection after type A surgery, from January 2007 to March 2013. Three intervals of computed tomography imaging were collected, including before and after primary TEVAR and with the first detection of distal SINE. Four accessible measurement methods for precise size selection of the stent graft before and after the procedure were analyzed at the distal end level of the primary stent graft. Results. Among the 139 patients, only 108 had complete preoperative and follow-up imaging and were enrolled in the study. The mean age of the patients was 59.7 +/- 11.7 years, and 92 patients (85.2%) were men. Seventy had type B aortic dissection, and 38 had residual aortic dissection after type A surgery. The mean follow-up period was 36.1 +/- 25.7 months. During follow-up, distal SINE occurred in 30 patients (27.8%), and 18 of them (60%) underwent secondary TEVAR whereas the remaining 12 patients were medically treated. No statistically significant differences in demographic and clinical conditions were seen between patients with or patients without SINE. The incidence of SINE was lower for acute than for chronic dissection (16% versus 50%). At the multivariate analysis, the independent factors associated with SINE development were the oversizing ratio of the area (odds ratio 1.858; 95% confidence interval: 1.109 to 3.064; p = 0.018) and of the mean diameter (odds ratio 1.858; 95% confidence interval: 1.109 to 3.064; p = 0.018). Conclusions. Type B aortic dissection can be treated effectively with TEVAR. The incidence of distal SINE is not negligible but is not associated with poor outcomes. The main determinant of SINE seems to be an excessive oversizing, which is particularly evident in the distal end. More accurate sizing can be obtained by evaluating the area of the true lumen. (C) 2016 by The Society of Thoracic Surgeons
引用
收藏
页码:527 / 533
页数:8
相关论文
共 50 条
  • [1] Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection
    Zhao, Yang
    Yin, Henghui
    Chen, Yitian
    Wang, Mian
    Zheng, Liang
    Li, Zilun
    Chang, Guangqi
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (01) : 93 - 103
  • [2] Risk factors for distal stent graft-induced new entry following endovascular repair of type B aortic dissection
    Li, Qing
    Wang, Long-Fei
    Ma, Wei-Guo
    Xu, Shang-Dong
    Zheng, Jun
    Xing, Xiao-Yan
    Huang, Lian-Jun
    Sun, Li-Zhong
    JOURNAL OF THORACIC DISEASE, 2015, 7 (11) : 1907 - 1916
  • [3] Risk factors for distal stent graft-induced new entry tear after endovascular repair of thoracic aortic dissection
    Canaud, Ludovic
    Gandet, Thomas
    Sfeir, Julien
    Ozdemir, Baris Ata
    Solovei, Laurence
    Alric, Pierre
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (05) : 1610 - 1614
  • [4] Total Endovascular Repair with Chimney Grafts for Distal Stent Graft-induced New Entry After Type B Aortic Dissection
    Umeno, Tadashi
    Ohki, Satoshi
    Yasuhara, Kiyomitsu
    Obayashi, Tamiyuki
    INDIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 8 : S185 - S187
  • [5] Risk factors for distal stent graft-induced new entry after endovascular repair in uncomplicated type B aortic dissection
    Xiang, Dongqiao
    Chai, Bin
    Gui, Yuxi
    Huang, Jia
    Liang, Huimin
    Liang, Bin
    Zhao, Huangxuan
    Yang, Fan
    Zheng, Chuansheng
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (01) : 37 - 45.e1
  • [6] Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection
    Dong, Zhihui
    Fu, Weiguo
    Wang, Yuqi
    Wang, Chunsheng
    Yan, Zhiping
    Guo, Daqiao
    Xu, Xin
    Chen, Bin
    JOURNAL OF VASCULAR SURGERY, 2010, 52 (06) : 1450 - 1457
  • [7] Distal Stent Graft-Induced New Entry After Frozen Elephant Trunk Procedure for Aortic Dissection
    Hiraoka, Toshifumi
    Furukawa, Tomokuni
    Imai, Katsuhiko
    Takahashi, Shinya
    ANNALS OF VASCULAR SURGERY, 2023, 97 : 340 - 350
  • [8] The Impact of Distal Stent Graft-Induced New Entry on Aortic Remodeling of Chronic Type B Dissection
    Huang, Chun-Yang
    Hsu, Hung-Lung
    Chen, Po-Lin
    Chen, I-Ming
    Hsu, Chiao-Po
    Shih, Chun-Che
    ANNALS OF THORACIC SURGERY, 2018, 105 (03): : 785 - 793
  • [9] Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection
    Weng, Shih-Hsien
    Weng, Chi-Feng
    Chen, Wei-Yuan
    Huang, Chun-Yang
    Chen, I-Ming
    Chen, Chun-Ku
    Hsu, Chiao-Po
    Shih, Chun-Che
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) : 64 - 71
  • [10] Relevance of Aortic Dissection Chronicity to the Development of Stent Graft-induced New Entry
    Ouchi, Takafumi
    Kato, Noriyuki
    Kato, Hiroaki
    Higashigawa, Takatoshi
    Ito, Hisato
    Nakajima, Ken
    Chino, Shuji
    Tokui, Toshiya
    Mizumoto, Toru
    Sakuma, Hajime
    ANNALS OF THORACIC SURGERY, 2020, 110 (06): : 1983 - 1989