The Impact of Distal Stent Graft-Induced New Entry on Aortic Remodeling of Chronic Type B Dissection

被引:29
|
作者
Huang, Chun-Yang
Hsu, Hung-Lung
Chen, Po-Lin
Chen, I-Ming
Hsu, Chiao-Po
Shih, Chun-Che
机构
[1] Taipei Vet Gen Hosp, Div Cardiovasc Surg, Dept Surg, Taipei, Taiwan
[2] Natl Yang Ming Univ, Inst Clin Med, Sch Med, Taipei, Taiwan
[3] Far Eastern Mem Hosp, Div Cardiovasc Surg, Taipei, Taiwan
来源
ANNALS OF THORACIC SURGERY | 2018年 / 105卷 / 03期
关键词
STEEL-BASED DEVICE; ENDOVASCULAR REPAIR; OUTCOMES;
D O I
10.1016/j.athoracsur.2017.08.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
C Background. In chronic type B aortic dissection, late distal stent graft-induced new entry (SINE) has a possible negative role in long-term aortic remodeling. This study aimed to investigate the impact of SINE occurrence on survival by evaluating true and false lumen remodeling in thoracic and abdominal segments at midterm surveillance. Methods. This study enrolled 65 patients with chronic type B aortic dissection (DeBakey type IIIb), who had received hybrid thoracic endovascular aortic repair (TEVAR) and had completed surveillance for at least 3 years. The 3-year survival rate was 84.7%. The patients were classified into non-SINE (n = 47) and SINE (n = 18) groups. Serial computed tomography scans were used to analyze volumetric change, true and false lumens, and thrombus volume from arch to aortic bifurcation level. Results. The SINE event occurred at a median of 22.5 months. In the SINE group, there was a significant interruption of the abdominal true lumen expansion in the second year (median 0.01 [interquartile range (IQR), -0.03 to 0.12] in the non-SINE group versus median -0.04 [IQR, -0.12 to 0.04] in the SINE group; p = 0.014). There was a significantly worse thoracic false lumen remodeling in the SINE group compared with the non-SINE group in the third year after the SINE event occurred (median 0 [IQR, -0.09 to 0.05] in the non-SINE group versus median 0.06 [IQR, 0 to 0.13] in the SINE group; p = 0.038). Conclusions. For chronic aortic dissection, late occurrence of distal SINE could influence abdominal true lumen expansion and thoracic false lumen shrinkage. Early reintervention for distal SINE could improve aortic remodeling in chronic aortic dissection. (C) 2018 by The Society of Thoracic Surgeons
引用
收藏
页码:785 / 793
页数:9
相关论文
共 50 条
  • [1] Impact Factors of Distal Stent Graft Induced New Entry in Type B Aortic Dissection
    Chen, I-Ming
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : S31 - S31
  • [2] Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection
    Zhao, Yang
    Yin, Henghui
    Chen, Yitian
    Wang, Mian
    Zheng, Liang
    Li, Zilun
    Chang, Guangqi
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (01) : 93 - 103
  • [3] Risk factors for distal stent graft-induced new entry following endovascular repair of type B aortic dissection
    Li, Qing
    Wang, Long-Fei
    Ma, Wei-Guo
    Xu, Shang-Dong
    Zheng, Jun
    Xing, Xiao-Yan
    Huang, Lian-Jun
    Sun, Li-Zhong
    JOURNAL OF THORACIC DISEASE, 2015, 7 (11) : 1907 - 1916
  • [4] Distal Stent Graft-Induced New Entry After TEVAR of Type B Aortic Dissection: Experience in 15 Years
    Li, Qing
    Ma, Wei-Guo
    Zheng, Jun
    Xu, Shang-Dong
    Chen, Yu
    Liu, Yong-Min
    Zhu, Jun-Ming
    Huang, Lian-Jun
    Sun, Li-Zhong
    ANNALS OF THORACIC SURGERY, 2019, 107 (03): : 718 - 724
  • [5] Total Endovascular Repair with Chimney Grafts for Distal Stent Graft-induced New Entry After Type B Aortic Dissection
    Umeno, Tadashi
    Ohki, Satoshi
    Yasuhara, Kiyomitsu
    Obayashi, Tamiyuki
    INDIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 8 : S185 - S187
  • [6] Risk factors for distal stent graft-induced new entry after endovascular repair in uncomplicated type B aortic dissection
    Xiang, Dongqiao
    Chai, Bin
    Gui, Yuxi
    Huang, Jia
    Liang, Huimin
    Liang, Bin
    Zhao, Huangxuan
    Yang, Fan
    Zheng, Chuansheng
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (01) : 37 - 45.e1
  • [7] Distal Stent Graft-Induced New Entry: An Emerging Complication of Endovascular Treatment in Aortic Dissection
    Pantaleo, Antonio
    Jafrancesco, Giuliano
    Buia, Francesco
    Leone, Alessandro
    Lovato, Luigi
    Russo, Vincenzo
    Di Marco, Luca
    Di Bartolomeo, Roberto
    Pacini, Davide
    ANNALS OF THORACIC SURGERY, 2016, 102 (02): : 527 - 533
  • [8] Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection
    Dong, Zhihui
    Fu, Weiguo
    Wang, Yuqi
    Wang, Chunsheng
    Yan, Zhiping
    Guo, Daqiao
    Xu, Xin
    Chen, Bin
    JOURNAL OF VASCULAR SURGERY, 2010, 52 (06) : 1450 - 1457
  • [9] Prevention of distal stent graft-induced new entry after endovascular repair for type B aortic dissection: A retrospective cohort study
    Li, Xianwei
    Zhang, Yingnan
    Sun, Zhanfeng
    Wang, Haitao
    Zhang, Chuanqi
    Cui, Yunfu
    Jiang, Weiliang
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 167 (01): : 28 - +
  • [10] Distal Stent Graft-Induced New Entry After Frozen Elephant Trunk Procedure for Aortic Dissection
    Hiraoka, Toshifumi
    Furukawa, Tomokuni
    Imai, Katsuhiko
    Takahashi, Shinya
    ANNALS OF VASCULAR SURGERY, 2023, 97 : 340 - 350