Risk factors for distal stent graft-induced new entry tear after endovascular repair of thoracic aortic dissection

被引:57
|
作者
Canaud, Ludovic [1 ]
Gandet, Thomas [1 ]
Sfeir, Julien [1 ]
Ozdemir, Baris Ata [1 ]
Solovei, Laurence [1 ]
Alric, Pierre [1 ,2 ]
机构
[1] Hop A Villeneuve, Dept Thorac & Cardiovasc Surg, Montpellier, France
[2] Univ Montpellier, PhyMedExp, CHU Montpellier, INSERM,CNRS, Montpellier, France
关键词
Thoracic aorta; Aortic dissection; Stent graft; TEVAR; Aorta;
D O I
10.1016/j.jvs.2018.07.086
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: A review of the literature was conducted for incidence, outcomes, and risk factors for distal stent graft-induced new entry (SINE) after thoracic endovascular aortic repair (TEVAR) of aortic dissection. Methods: The review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Results: Seven articles reporting on 1415 patients with thoracic aortic dissection undergoing TEVAR without supplemental distal bare stenting were included. In this cohort, 86 patients were treated for a residual type A aortic dissection and 1329 for a complicated type B aortic dissection. Distal SINE occurred in 112 patients (7.9%). The mean time to identification of distal SINE was 19 6 7 months. The incidence of distal SINE after TEVAR for type B aortic dissection differed on the basis of whether it was a chronic or acute dissection repair and was, respectively, 12.9% (43/331) and 4.3% (12/273). Successful secondary interventions were performed in 54% of the patients. All the studies analyzing the relationship between distal stent graft oversizing and incidence of distal SINE reported a significantly higher rate of SINE with oversizing. Conclusions: The successful management of complicated descending thoracic aortic dissections by TEVAR is well established. Whereas distal SINE is relatively frequent, if it does occur, the complication can generally be treated with additional TEVAR without a poor outcome. The main determinant of SINE seems to be excessive distal oversizing.
引用
收藏
页码:1610 / 1614
页数:5
相关论文
共 50 条
  • [1] Incidence and risk factors for retrograde type A dissection and stent graft-induced new entry after thoracic endovascular aortic repair
    Ma, Tao
    Dong, Zhi Hui
    Fu, Wei Guo
    Guo, Da Qiao
    Xu, Xin
    Chen, Bin
    Jiang, Jun Hao
    Yang, Jue
    Shi, Zhen Yu
    Zhu, Ting
    Shi, Yun
    Jiang, Bao Hong
    Xu, Xiao Yun
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (04) : 1026 - +
  • [2] Risk factors for distal stent graft-induced new entry after endovascular repair in uncomplicated type B aortic dissection
    Xiang, Dongqiao
    Chai, Bin
    Gui, Yuxi
    Huang, Jia
    Liang, Huimin
    Liang, Bin
    Zhao, Huangxuan
    Yang, Fan
    Zheng, Chuansheng
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (01) : 37 - 45.e1
  • [3] Risk factors for stent graft-induced new entry after thoracic endovascular aortic repair for Stanford type B aortic dissection
    Jang, Hyunsik
    Kim, Man-Deuk
    Kim, Gyoung Min
    Won, Jong Yun
    Ko, Young-Guk
    Choi, Donghoon
    Joo, Hyun-Chul
    Lee, Do Yun
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (03) : 676 - 685
  • [4] Risk factors for distal stent graft-induced new entry following endovascular repair of type B aortic dissection
    Li, Qing
    Wang, Long-Fei
    Ma, Wei-Guo
    Xu, Shang-Dong
    Zheng, Jun
    Xing, Xiao-Yan
    Huang, Lian-Jun
    Sun, Li-Zhong
    JOURNAL OF THORACIC DISEASE, 2015, 7 (11) : 1907 - 1916
  • [5] Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection
    Dong, Zhihui
    Fu, Weiguo
    Wang, Yuqi
    Wang, Chunsheng
    Yan, Zhiping
    Guo, Daqiao
    Xu, Xin
    Chen, Bin
    JOURNAL OF VASCULAR SURGERY, 2010, 52 (06) : 1450 - 1457
  • [6] Total Endovascular Repair with Chimney Grafts for Distal Stent Graft-induced New Entry After Type B Aortic Dissection
    Umeno, Tadashi
    Ohki, Satoshi
    Yasuhara, Kiyomitsu
    Obayashi, Tamiyuki
    INDIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 8 : S185 - S187
  • [7] Early Prediction of Distal Stent Graft-Induced New Entry after Thoracic Endovascular Aortic Repair with Computational Fluid Dynamics
    School of Medical Technology, Beijing Institute of Technology, China
    ACM Int. Conf. Proc. Ser., 1600, (84-90):
  • [8] Distal Stent Graft-Induced New Entry: An Emerging Complication of Endovascular Treatment in Aortic Dissection
    Pantaleo, Antonio
    Jafrancesco, Giuliano
    Buia, Francesco
    Leone, Alessandro
    Lovato, Luigi
    Russo, Vincenzo
    Di Marco, Luca
    Di Bartolomeo, Roberto
    Pacini, Davide
    ANNALS OF THORACIC SURGERY, 2016, 102 (02): : 527 - 533
  • [9] Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection
    Zhao, Yang
    Yin, Henghui
    Chen, Yitian
    Wang, Mian
    Zheng, Liang
    Li, Zilun
    Chang, Guangqi
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (01) : 93 - 103
  • [10] Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection
    Weng, Shih-Hsien
    Weng, Chi-Feng
    Chen, Wei-Yuan
    Huang, Chun-Yang
    Chen, I-Ming
    Chen, Chun-Ku
    Hsu, Chiao-Po
    Shih, Chun-Che
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) : 64 - 71