Application on the Stratified Air Conditioning System with Low Velocity in the Main Hall of the Temple

被引:0
|
作者
Huang, Yiyun [1 ]
Zhang, Ling [1 ]
Han, Xiaohong
机构
[1] Zhejiang Coll Construct, Hangzhou 311231, Zhejiang, Peoples R China
来源
GREEN BUILDING MATERIALS AND ENERGY-SAVING CONSTRUCTION | 2011年 / 280卷
关键词
stratified air conditioning; temple; low velocity; fan coil; large space;
D O I
10.4028/www.scientific.net/AMR.280.141
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a design scheme of the stratified air conditioning system, in accordance with the temple hall's large space and function characteristics. The indoor stratified air conditioning environment is formed by the low velocity air supply of fan coil units embedded below the Buddha statue. The interface of stratified air is only 1.7m high, because the large amount of air unavoidably penetrates the room due to the prohibition of closing the door. From the tested results, the design not only meet the temple hall's operational requirements for decoration and the open front door, but also greatly reduces the energy consumption of the air conditioning at the cost of the comfortable feeling of air conditioning. In this work, some suggestions are also given in order to further improve the comfort and lower the energy use.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [21] Application of QFD in the design of the large central air conditioning system
    Jiang, H
    Lu, WX
    Yang, CP
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1 AND 2: MODERN INDUSTRIAL ENGINEERING AND INNOVATION IN ENTERPRISE MANAGEMENT, 2005, : 1355 - 1359
  • [22] A Preliminary Research on Load Calculation Method of Stratified Air Conditioning System with Low-sidewall Air Inlets and Middle-height Air Outlets in Large Space Building
    Huang, Chen
    Yue, Jing
    Bai, Tianyu
    Lv, Liugen
    Zhang, Qianru
    Chen, Jianchang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2561 - 2568
  • [23] Staged variable air volume air-conditioning system and its application in stores
    Zhao, JN
    Guo, J
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1247 - 1253
  • [24] Discussion on the Application of Variable-air-volume Air-conditioning System on Ships
    Guo, Junjie
    Chen, Wu
    Cai, Zhenxiong
    Zheng, Chaoyu
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 413 - 418
  • [25] Study on the Application of Rotary Desiccant Air-Conditioning System on Ships
    Chen, Wu
    Yang, Guanghai
    ADVANCED SCIENCE LETTERS, 2011, 4 (4-5) : 1410 - 1415
  • [26] Application of Internal Cooled Desiccant Wheel in Air-Conditioning System
    Zhou Xingchao
    Goldsworthy, Mark
    Sproul, Alistair
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [27] Application of Fuzzy PID for the Ventilation and Air Conditioning System of Subway Station
    Wang Jia
    Wang Feng
    Jiang Yong
    Chen Zhixin
    Yan Shitian
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 : 811 - +
  • [28] Research of cascade control with an application to central air-conditioning system
    Wang, Jiang-Jiang
    Zhang, Chun-Fa
    Jing, You-Yin
    PROCEEDINGS OF 2007 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2007, : 498 - 503
  • [29] Improved CMAC neural network in the application of the VAV air conditioning system
    Li, Jie Jia, 1600, Sila Science, University Mah Mekan Sok, No 24, Trabzon, Turkey (32):
  • [30] Application of geothermal absorption air-conditioning system: A case study
    Wang, Xiaolin
    Bierwirth, Alex
    Christ, Alexander
    Whittaker, Peter
    Regenauer-Lieb, Klaus
    Chua, Hui Tong
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 71 - 80