Detection and segmental location of malignant hepatic tumors: Comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging

被引:39
|
作者
VanBeers, BE
Lacrosse, M
Jamart, J
Grandin, C
Gigot, JF
Horsmans, Y
Demeure, R
Pringot, J
机构
[1] UNIV CATHOLIQUE LOUVAIN,MONT GODINNE UNIV HOSP,DEPT RADIOL,B-5530 YVOIR,BELGIUM
[2] UNIV CATHOLIQUE LOUVAIN,MONT GODINNE UNIV HOSP,CTR BIOSTAT & MED DOCUMENTAT,B-5530 YVOIR,BELGIUM
[3] UNIV CATHOLIQUE LOUVAIN,ST LUC UNIV HOSP,DEPT SURG,B-1200 BRUSSELS,BELGIUM
[4] UNIV CATHOLIQUE LOUVAIN,ST LUC UNIV HOSP,DIV GASTROENTEROL,B-1200 BRUSSELS,BELGIUM
关键词
D O I
10.2214/ajr.168.3.9057521
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of our prospective study was to compare the values of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging for the detection and segmental location of malignant hepatic tumors. SUBJECTS AND METHODS. Eighteen patients underwent ferumoxides-enhanced T2-weighted spin-echo and steady-state gradient-echo imaging before surgery, Intraoperative sonography was used as the reference examination and showed 28 malignant tumors involving 39 of the 144 hepatic segments. The MR images were reviewed independently by two observers who recorded the number of tumors and their segmental location. The results of the segmental location were subjected to receiver-operating-characteristic analysis. Tumor-liver, vessel-liver, and tumor-vessel contrast-to-noise ratios were calculated. RESULTS. Detection on the gradient-echo images did not differ significantly from that on the T2-weighted spin-echo MR images (observers A and B detected 23 and 24 tumors, respectively, on the gradient-echo images; the two observers each detected 22 tumors on the T2-weighted spin-echo images). Segmental localization was significantly better on the gradient-echo images than on the T2-weighted spin-echo images (mean area under the receiver-operating-characteristic curve: 0.974 versus 0.895 for observer A and 0.962 versus 0.906 for observer B, p =.024). The highest contrast-to-noise ratios for vessel to liver and tumor to vessel were obtained on the gradient-echo images and the highest tumor-liver contrast-to-noise ratio was obtained on the T2-weighted spin-echo images. CONCLUSION. In our study, ferumoxides-enhanced gradient-echo imaging was as accurate as T2-weighted spin-echo imaging for revealing malignant hepatic tumors and was superior for showing their segmental location.
引用
收藏
页码:713 / 717
页数:5
相关论文
共 50 条
  • [41] MR IMAGING OF THE PORTAL VENOUS SYSTEM - VALUE OF GRADIENT-ECHO IMAGING AS AN ADJUNCT TO SPIN-ECHO IMAGING
    SILVERMAN, PM
    PATT, RH
    GARRA, BS
    HORII, SC
    COOPER, C
    HAYES, WS
    ZEMAN, RK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (02) : 297 - 302
  • [42] MR contrast of ferritin and hemosiderin in the brain: comparison among gradient-echo, conventional spin-echo and fast spin-echo sequences
    Haque, TL
    Miki, Y
    Kanagaki, M
    Takahashi, T
    Yamamoto, A
    Konishi, J
    Nozaki, K
    Hashimoto, N
    Konishi, J
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (03) : 230 - 236
  • [43] Perfusion-sensitive MR imaging of gliomas: Comparison between gradient-echo and spin-echo echo-planar imaging techniques
    Sugahara, T
    Korogi, Y
    Kochi, M
    Ushio, Y
    Takahashi, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (07) : 1306 - 1315
  • [44] MRI of the uterus, uterine cervix, and vagina: diagnostic performance of dynamic contrast-enhanced fast multiplanar gradient-echo imaging in comparison with fast spin-echo T2-weighted pulse imaging
    P.-F. Liu
    G. P. Krestin
    R. A. Huch
    S. C. Göhde
    R. F. Caduff
    J. F. Debatin
    European Radiology, 1998, 8 : 1433 - 1440
  • [45] Gradient- and spin-echo T2-weighted imaging for SPIO-enhanced detection and characterization of focal liver lesions
    Yoshikawa, T
    Mitchell, DG
    Hirota, S
    Ohno, Y
    Oda, K
    Maeda, T
    Fujii, M
    Sugimura, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) : 712 - 719
  • [46] T2-WEIGHTED MR-IMAGING OF THE CHEST - COMPARISON OF ELECTROCARDIOGRAPH-TRIGGERED CONVENTIONAL AND TURBO SPIN-ECHO AND NONTRIGGERED TURBO SPIN-ECHO SEQUENCES
    HADDAD, JL
    ROFSKY, NM
    AMBROSINO, MM
    NAIDICH, DP
    WEINREB, JC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 325 - 329
  • [47] MAGNETIZATION PREPARED RAPID GRADIENT-ECHO (MP-RAGE) MR IMAGING OF THE LIVER - COMPARISON WITH SPIN-ECHO IMAGING
    DELANGE, EE
    MUGLER, JP
    BERTOLINA, JA
    GAY, SB
    JANUS, CL
    BROOKEMAN, JR
    MAGNETIC RESONANCE IMAGING, 1991, 9 (04) : 469 - 476
  • [48] Comparison of dynamic contrast-enhanced gradient-echo and spin-echo sequences in MR of head and neck neoplasms
    Escott, EJ
    Rao, VM
    Ko, WD
    Guitierrez, JE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (08) : 1411 - 1419
  • [49] MUSCULOSKELETAL MR-IMAGING - TURBO (FAST) SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO AND GRADIENT-ECHO IMAGING AT 0.5-TESLA
    VAHLENSIECK, M
    LANG, P
    SEELOS, K
    SZE, DYH
    GRAMPP, S
    REISER, M
    SKELETAL RADIOLOGY, 1994, 23 (08) : 607 - 610
  • [50] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tamada, T
    Sone, T
    Nagai, K
    Jo, Y
    Gyoten, M
    Imai, S
    Kajihara, Y
    Fukunaga, M
    EUROPEAN RADIOLOGY, 2004, 14 (02) : 318 - 325