Detection and segmental location of malignant hepatic tumors: Comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging

被引:39
|
作者
VanBeers, BE
Lacrosse, M
Jamart, J
Grandin, C
Gigot, JF
Horsmans, Y
Demeure, R
Pringot, J
机构
[1] UNIV CATHOLIQUE LOUVAIN,MONT GODINNE UNIV HOSP,DEPT RADIOL,B-5530 YVOIR,BELGIUM
[2] UNIV CATHOLIQUE LOUVAIN,MONT GODINNE UNIV HOSP,CTR BIOSTAT & MED DOCUMENTAT,B-5530 YVOIR,BELGIUM
[3] UNIV CATHOLIQUE LOUVAIN,ST LUC UNIV HOSP,DEPT SURG,B-1200 BRUSSELS,BELGIUM
[4] UNIV CATHOLIQUE LOUVAIN,ST LUC UNIV HOSP,DIV GASTROENTEROL,B-1200 BRUSSELS,BELGIUM
关键词
D O I
10.2214/ajr.168.3.9057521
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of our prospective study was to compare the values of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging for the detection and segmental location of malignant hepatic tumors. SUBJECTS AND METHODS. Eighteen patients underwent ferumoxides-enhanced T2-weighted spin-echo and steady-state gradient-echo imaging before surgery, Intraoperative sonography was used as the reference examination and showed 28 malignant tumors involving 39 of the 144 hepatic segments. The MR images were reviewed independently by two observers who recorded the number of tumors and their segmental location. The results of the segmental location were subjected to receiver-operating-characteristic analysis. Tumor-liver, vessel-liver, and tumor-vessel contrast-to-noise ratios were calculated. RESULTS. Detection on the gradient-echo images did not differ significantly from that on the T2-weighted spin-echo MR images (observers A and B detected 23 and 24 tumors, respectively, on the gradient-echo images; the two observers each detected 22 tumors on the T2-weighted spin-echo images). Segmental localization was significantly better on the gradient-echo images than on the T2-weighted spin-echo images (mean area under the receiver-operating-characteristic curve: 0.974 versus 0.895 for observer A and 0.962 versus 0.906 for observer B, p =.024). The highest contrast-to-noise ratios for vessel to liver and tumor to vessel were obtained on the gradient-echo images and the highest tumor-liver contrast-to-noise ratio was obtained on the T2-weighted spin-echo images. CONCLUSION. In our study, ferumoxides-enhanced gradient-echo imaging was as accurate as T2-weighted spin-echo imaging for revealing malignant hepatic tumors and was superior for showing their segmental location.
引用
收藏
页码:713 / 717
页数:5
相关论文
共 50 条
  • [21] THE PELVIS - T2-WEIGHTED FAST SPIN-ECHO MR-IMAGING
    NGHIEM, HV
    HERFKENS, RJ
    FRANCIS, IR
    SOMMER, FG
    JEFFREY, RB
    LI, KCP
    STEINER, RM
    GLOVER, GH
    RADIOLOGY, 1992, 185 (01) : 213 - 217
  • [22] T2-weighted fast spin-echo MR imaging of liver.
    Mirowitz, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 263 - 264
  • [23] COMPARISON OF T2-WEIGHTED SPIN-ECHO AND FAST SPIN-ECHO TECHNIQUES IN THE EVALUATION OF MYELINATION
    PRENGER, EC
    BECKETT, WW
    KOLLIAS, SS
    BALL, WS
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02): : 179 - 184
  • [24] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [25] Can inversion-recovery gradient- and spin-echo T2-weighted MR imaging be an alternative to fast spin-echo imaging with fat suppression?
    Kanematsu, M
    Hoshi, H
    RADIOLOGY, 1999, 212 (01) : 291 - 291
  • [26] Detection of focal hepatic lesions with MR imaging: Prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging
    Soyer, P
    deGivry, SC
    Gueye, C
    Lenormand, S
    Somveille, E
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1115 - 1121
  • [27] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [28] Ferumoxides-enhanced double-echo T2-weighted MR imaging in differentiating metastases from nonsolid benign lesions of the liver
    Arbab, AS
    Ichikawa, T
    Sou, H
    Araki, T
    Nakajima, H
    Ishigame, K
    Yoshikawa, T
    Kumagai, H
    RADIOLOGY, 2002, 225 (01) : 151 - 158
  • [29] Stomach diseases: MR evaluation using combined T2-weighted single-shot echo train spin-echo and gadolinium-enhanced spoiled gradient-echo sequences
    Marcos, HB
    Semelka, RC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (06): : 950 - 960
  • [30] Focal liver lesions: Characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging
    Schima, W
    Saini, S
    Echeverri, JA
    Hahn, PF
    Harisinghani, M
    Mueller, PR
    RADIOLOGY, 1997, 202 (02) : 389 - 393