Detection and segmental location of malignant hepatic tumors: Comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging

被引:39
|
作者
VanBeers, BE
Lacrosse, M
Jamart, J
Grandin, C
Gigot, JF
Horsmans, Y
Demeure, R
Pringot, J
机构
[1] UNIV CATHOLIQUE LOUVAIN,MONT GODINNE UNIV HOSP,DEPT RADIOL,B-5530 YVOIR,BELGIUM
[2] UNIV CATHOLIQUE LOUVAIN,MONT GODINNE UNIV HOSP,CTR BIOSTAT & MED DOCUMENTAT,B-5530 YVOIR,BELGIUM
[3] UNIV CATHOLIQUE LOUVAIN,ST LUC UNIV HOSP,DEPT SURG,B-1200 BRUSSELS,BELGIUM
[4] UNIV CATHOLIQUE LOUVAIN,ST LUC UNIV HOSP,DIV GASTROENTEROL,B-1200 BRUSSELS,BELGIUM
关键词
D O I
10.2214/ajr.168.3.9057521
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of our prospective study was to compare the values of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging for the detection and segmental location of malignant hepatic tumors. SUBJECTS AND METHODS. Eighteen patients underwent ferumoxides-enhanced T2-weighted spin-echo and steady-state gradient-echo imaging before surgery, Intraoperative sonography was used as the reference examination and showed 28 malignant tumors involving 39 of the 144 hepatic segments. The MR images were reviewed independently by two observers who recorded the number of tumors and their segmental location. The results of the segmental location were subjected to receiver-operating-characteristic analysis. Tumor-liver, vessel-liver, and tumor-vessel contrast-to-noise ratios were calculated. RESULTS. Detection on the gradient-echo images did not differ significantly from that on the T2-weighted spin-echo MR images (observers A and B detected 23 and 24 tumors, respectively, on the gradient-echo images; the two observers each detected 22 tumors on the T2-weighted spin-echo images). Segmental localization was significantly better on the gradient-echo images than on the T2-weighted spin-echo images (mean area under the receiver-operating-characteristic curve: 0.974 versus 0.895 for observer A and 0.962 versus 0.906 for observer B, p =.024). The highest contrast-to-noise ratios for vessel to liver and tumor to vessel were obtained on the gradient-echo images and the highest tumor-liver contrast-to-noise ratio was obtained on the T2-weighted spin-echo images. CONCLUSION. In our study, ferumoxides-enhanced gradient-echo imaging was as accurate as T2-weighted spin-echo imaging for revealing malignant hepatic tumors and was superior for showing their segmental location.
引用
收藏
页码:713 / 717
页数:5
相关论文
共 50 条
  • [1] Focal nodular hyperplasia of the liver on ferumoxides-enhanced MR imaging: Comparison of conventional spin-echo, fast spin-echo and gradient-echo images
    Precetti, S
    Bellin, M
    Ghebontni, L
    Zaim, S
    Cluzel, P
    Grenier, PA
    RADIOLOGY, 1997, 205 : 1330 - 1330
  • [2] Focal nodular hyperplasia of the liver on ferumoxides-enhanced MR imaging: features on conventional spin-echo, fast spin-echo and gradient-echo pulse sequences
    S. Precetti-Morel
    M. F. Bellin
    L. Ghebontni
    S. Zaïm
    P. Opolon
    T. Poynard
    P. Mathurin
    P. Cluzel
    European Radiology, 1999, 9 : 1535 - 1542
  • [3] Focal nodular hyperplasia of the liver on ferumoxides-enhanced MR imaging:: features on conventional spin-echo, fast spin-echo and gradient-echo pulse sequences
    Precetti-Morel, S
    Bellin, MF
    Ghebontni, L
    Zaïm, S
    Opolon, P
    Poynard, T
    Mathurin, P
    Cluzel, P
    EUROPEAN RADIOLOGY, 1999, 9 (08) : 1535 - 1542
  • [4] Optimal MR protocol for hepatic hemangiomas - Comparison of conventional spin-echo sequences with T2-weighted turbo spin-echo and serial gradient-echo (FLASH) sequences with gadolinium enhancement
    Kim, TK
    Choi, BI
    Han, JK
    Jang, HJ
    Han, MC
    ACTA RADIOLOGICA, 1997, 38 (04) : 565 - 571
  • [5] Characterization of focal hepatic lesions with ferumoxides-enhanced T2-weighted MR imaging
    Paley, MR
    Mergo, PJ
    Torres, GM
    Ros, PR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (01) : 159 - 163
  • [6] GRADIENT-ECHO MR IMAGING OF THE LUMBAR SPINE - COMPARISON WITH SPIN-ECHO TECHNIQUE
    WATANABE, AT
    TEITELBAUM, GP
    LUFKIN, RB
    TSURUDA, JS
    JINKINS, JR
    BRADLEY, WG
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) : 410 - 414
  • [7] Comparison of Spin-Echo and Gradient-Echo T1-Weighted and Spin-Echo T2-Weighted Images at 3T in Evaluating Term-Neonatal Myelination
    Tyan, A. E.
    McKinney, A. M.
    Hanson, T. J.
    Truwit, C. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 411 - 416
  • [8] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [9] MR-IMAGING OF THE BRAIN - COMPARISON OF GRADIENT-ECHO AND SPIN-ECHO PULSE SEQUENCES
    PUI, MH
    FOK, ECM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (04) : 959 - 962
  • [10] COMPARISON OF SPIN-ECHO AND GRADIENT-ECHO TRANSAXIAL MR IMAGING FOR SCREENING THE LUMBAR SPINE
    WATANABE, AT
    TEITELBAUM, GP
    LUFKIN, RB
    KINKINS, JR
    TSURUDA, JT
    BRADLEY, WG
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (05) : 1002 - 1002