Quantification of motion artifact in ECG electrode design

被引:10
|
作者
Kearney, Kenneth [1 ]
Thomas, Chris [2 ]
McAdams, Eric [3 ]
机构
[1] Sensor Technol & Devices Ltd, 4 Heron Rd, Belfast BT3 9LE, Antrim, North Ireland
[2] Univ Ulster, Dept Elect Engn, Jordanstown BT370QB, England
[3] Univ Ulster, Jordanstown BT37 0QB, England
关键词
D O I
10.1109/IEMBS.2007.4352594
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a more accurate and reproducible method of quantifying motion artifact in ECG (electrocardiogram) electrodes to assist in electrode assessment and design. It uses an algorithm developed by Sensor Technology & Devices Ltd. to reliably overcome the variation in results due to differing skin types and other causes of spurious readings such as reproducibility of movements used. The method combines a clear, concise experimental protocol with a software package and DSP algorithm to produce a transferable result for one pair of electrodes that can be used for comparison.
引用
收藏
页码:1533 / +
页数:2
相关论文
共 50 条
  • [41] A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking
    An, Xiang
    Stylios, George K.
    MATERIALS, 2018, 11 (10)
  • [42] Design of filter to reject motion artifact of pulse oximetry
    Lee, J
    Jung, W
    Kang, I
    Kim, Y
    Lee, G
    COMPUTER STANDARDS & INTERFACES, 2004, 26 (03) : 241 - 249
  • [43] Adaptive Motion Artifact Reduction in Wearable ECG Measurements Using Impedance Pneumography Signal
    An, Xiang
    Liu, Yanzhong
    Zhao, Yixin
    Lu, Sichao
    Stylios, George K.
    Liu, Qiang
    SENSORS, 2022, 22 (15)
  • [44] Robust wireless capacitive ECG system with adaptive signal quality and motion artifact reduction
    Castro, I. D.
    Morariu, R.
    Torfs, T.
    Van Hoof, C.
    Puers, R.
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 585 - 590
  • [45] ECG Motion Artifact Filtering Based on Two-Stage Adaptive Threshold Rules
    Lü, Jian-Hang
    Li, Yu-Rong
    Chen, Jian-Guo
    Gao, Ning
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2024, 52 (10): : 3493 - 3506
  • [46] Development of Automatic Motion Artifact Detection in Mobile ECG Monitor Based on Wavelet Transform
    Shi, Fan
    Li, Xueen
    2012 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT CONTROL, AUTOMATIC DETECTION AND HIGH-END EQUIPMENT (ICADE), 2012, : 166 - 170
  • [47] Noncontact ECG Recording System With Real Time Capacitance Measurement for Motion Artifact Reduction
    Torfs, Tom
    Chen, Yun-Hsuan
    Kim, Hyejung
    Yazicioglu, Refet Firat
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (05) : 617 - 625
  • [48] Motion Artifact Removal using Cascade Adaptive Filtering for Ambulatory ECG Monitoring System
    Kim, Hyejung
    Kim, Sunyoung
    Van Helleputte, Nick
    Berset, Torfinn
    Geng, Di
    Romero, Inaki
    Penders, Julien
    Van Hoof, Chris
    Yazicioglu, Refet Firat
    2012 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): INTELLIGENT BIOMEDICAL ELECTRONICS AND SYSTEM FOR BETTER LIFE AND BETTER ENVIRONMENT, 2012, : 160 - 163
  • [49] ECG example: artifact in hyperventilation
    Michalski, T.
    Fritsch, G.
    Franz, A.
    Eigenstuhler, J.
    JOURNAL FUR KARDIOLOGIE, 2013, 20 (1-2): : 30 - 30
  • [50] ARTIFACT AND SAFETY IN ECG MONITORING
    JONES, PL
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1973, 66 (12): : 1211 - 1215