A Novel Method for Hyperacuity Measurement

被引:0
|
作者
Kim, Jin Ha [1 ]
Lim, Key Hwan [1 ]
Kim, Yun Taek [2 ]
机构
[1] Ewha Womans Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Cheonan Kims Eye Clin, 92 Jungang Ro, Cheonan 31127, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2020年 / 61卷 / 02期
关键词
Hyperacuity; Vernier acuity; 3-Dimensional hyperacuity test; PHOTODYNAMIC THERAPY; METAMORPHOPSIA;
D O I
10.3341/jkos.2020.61.2.175
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We developed a novel method for measurement of hyperacuity and verified the utility thereof. Methods: We developed a three-dimensional (3D) hyperacuity test using a 3D liquid crystal flat screen, a left- and right-image polarized display, and liquid crystal shutter glasses. We tested the technique in three groups: normal (n = 48), with cataracts (n = 14), and with macular disease (n = 35). We used a chart consisting of five dots and a reference line. Of the five dots, one was variably shifted from the other dots. A chart was presented to one eye and the reference line or blank image to the other eye; a subject scored positive when the dot in the unusual position was recognized. Results: Hyperacuity was measured in terms of the reference line seen by the reference eye (RR), a blank image seen by the reference eye (RB), the reference line seen by the contralateral eye (CR), and a blank image seen by the contralateral eye (CB). All test scores were significantly lower when the reference line was seen than not (RR vs. RB and CR vs. CB; p < 0.01, respectively). For the RR and CR tests, no significant difference was apparent between the normal and cataracts group (p = 0.553, p = 0.494) but such differences were evident between the normal and macular disease groups (p = 0.028, p = 0.002). Also, visualization of the reference line by the reference and contralateral eyes did not differ (p > 0.05). Conclusions: Measurement of hyperacuity using our new method was not affected by media opacity but was significantly affected by macular disease. Presentation of a reference line facilitated hyperacuity assessment.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [41] A novel method for measurement and characterization of soil macroporosity
    Barton, C
    Karathanasis, T
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2002, 33 (7-8) : 1305 - 1322
  • [42] A Novel Method for the Measurement of Retinal Arteriolar Bifurcation
    Dai, Guangzheng
    Yu, Sile
    Hu, Shenming
    Luan, Xinze
    Yan, Hairu
    Wang, Xiaoting
    Song, Pengfei
    Liu, Xinying
    He, Xingru
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (04) : 917 - 933
  • [43] A novel measurement method of polarization mode dispersion
    Gong, YD
    Guan, YL
    Jiang, FY
    Cai, Q
    Jian, SS
    FIBER OPTIC COMPONENTS AND OPTICAL COMMUNICATION, 1996, 2893 : 335 - 338
  • [44] A novel method of heart rate variability measurement
    Shao Shi-Liang
    Wang Ting
    Song Chun-He
    Cui E-Nuo
    Zhao Hai
    Yao Chen
    ACTA PHYSICA SINICA, 2019, 68 (17)
  • [45] A Novel Method for Rapid Bedside Measurement of GFR
    Rizk, Dana V.
    Meier, Daniel
    Sandoval, Ruben M.
    Chacana, Teresa
    Reilly, Erinn S.
    Seegmiller, Jesse C.
    DeNoia, Emmanuel
    Strickland, James S.
    Muldoon, Joseph
    Molitoris, Bruce A.
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2018, 29 (06): : 1609 - 1613
  • [46] A Novel Evaluation Method For Particle Deposition Measurement
    Song, Tao
    Liu, Chao
    Zhu, Hengxuan
    Zeng, Min
    Wang, Jin
    OPEN PHYSICS, 2019, 17 (01): : 927 - 934
  • [47] NOVEL METHOD OF PROBE HOLE CURRENT MEASUREMENT
    DIFOGGIO, R
    GOMER, R
    ULTRAMICROSCOPY, 1979, 4 (03) : 377 - 377
  • [48] Novel, lower cost, noise measurement method
    Mitsdarffer, K. B.
    Thelen, D.
    AUTOTESTCON 2005, 2005, : 674 - 676
  • [49] A Novel New Gate Charge Measurement Method
    Mikata, Atsushi
    Kakitani, Hisao
    Takeda, Ryo
    Wadsworth, Alan
    PROCEEDINGS OF THE 2015 IEEE INTERNATIONAL CONFERENCE ON MICROELECTRONIC TEST STRUCTURES (ICMTS 2015), 2015, : 138 - 140
  • [50] Novel method for measurement of total hemispherical emissivity
    Moghaddam, Saeed
    Lawler, John
    Currano, Joseph
    Kim, Jungho
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2007, 21 (01) : 128 - 133