A Novel Method for Hyperacuity Measurement

被引:0
|
作者
Kim, Jin Ha [1 ]
Lim, Key Hwan [1 ]
Kim, Yun Taek [2 ]
机构
[1] Ewha Womans Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Cheonan Kims Eye Clin, 92 Jungang Ro, Cheonan 31127, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2020年 / 61卷 / 02期
关键词
Hyperacuity; Vernier acuity; 3-Dimensional hyperacuity test; PHOTODYNAMIC THERAPY; METAMORPHOPSIA;
D O I
10.3341/jkos.2020.61.2.175
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We developed a novel method for measurement of hyperacuity and verified the utility thereof. Methods: We developed a three-dimensional (3D) hyperacuity test using a 3D liquid crystal flat screen, a left- and right-image polarized display, and liquid crystal shutter glasses. We tested the technique in three groups: normal (n = 48), with cataracts (n = 14), and with macular disease (n = 35). We used a chart consisting of five dots and a reference line. Of the five dots, one was variably shifted from the other dots. A chart was presented to one eye and the reference line or blank image to the other eye; a subject scored positive when the dot in the unusual position was recognized. Results: Hyperacuity was measured in terms of the reference line seen by the reference eye (RR), a blank image seen by the reference eye (RB), the reference line seen by the contralateral eye (CR), and a blank image seen by the contralateral eye (CB). All test scores were significantly lower when the reference line was seen than not (RR vs. RB and CR vs. CB; p < 0.01, respectively). For the RR and CR tests, no significant difference was apparent between the normal and cataracts group (p = 0.553, p = 0.494) but such differences were evident between the normal and macular disease groups (p = 0.028, p = 0.002). Also, visualization of the reference line by the reference and contralateral eyes did not differ (p > 0.05). Conclusions: Measurement of hyperacuity using our new method was not affected by media opacity but was significantly affected by macular disease. Presentation of a reference line facilitated hyperacuity assessment.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [21] Sensitive (Anxiety, hyperacuity)
    Hudgins, A
    AMERICAN SCHOLAR, 2002, 71 (04): : 39 - 51
  • [22] A novel measurement method for incidental PM at AM
    Zhou, Feng
    Zhang, Rui
    Gao, You-Gang
    Ruan, Fang-Ming
    Shen, Yuan-Mao
    Shi, Dan
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2012, 40 (03): : 592 - 594
  • [23] Novel method for superconducting energy gap measurement
    Mizushima, Koichi
    Inque, Shinji
    Sagoi, Masayuki
    Yoshida, Jiro
    1600, (30):
  • [24] Novel probe position for WBFC measurement method
    Ruzek, Vaclav
    Drinovsky, Jiri
    Zachar, Jiri
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (3A): : 220 - 224
  • [25] A NOVEL METHOD FOR THE MEASUREMENT OF THE BACKSCATTERING ENHANCEMENT IN EPMA
    ELGOMATI, MM
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1988, (93): : 167 - 168
  • [26] Novel method for precise focal length measurement
    DeBoo, BJ
    Sasian, JM
    INTERNATIONAL OPTICAL DESIGN CONFERENCE 2002, 2002, 4832 : 114 - 121
  • [27] A novel measurement method of segregating adlayers in MBE
    Oehme, M
    Bauer, M
    Grasby, T
    Kasper, E
    THIN SOLID FILMS, 2000, 369 (1-2) : 138 - 142
  • [28] NOVEL METHOD FOR NONCONTACT MEASUREMENT OF PARTICLE TEMPERATURES
    WAGENAAR, BM
    MEIJER, R
    KUIPERS, JAM
    VANSWAAIJ, WPM
    AICHE JOURNAL, 1995, 41 (04) : 773 - 782
  • [29] A NOVEL METHOD FOR THE MEASUREMENT OF THE BACKSCATTERING ENHANCEMENT IN EPMA
    ELGOMATI, MM
    EUREM 88, VOLS 1-3: TUTORIALS, INSTRUMENTATION AND TECHNIQUES / PHYSICS AND MATERIALS / BIOLOGY, 1988, 93 : 167 - 168
  • [30] A Novel Method for the Measurement of Retinal Arteriolar Bifurcation
    Guangzheng Dai
    Sile Yu
    Shenming Hu
    Xinze Luan
    Hairu Yan
    Xiaoting Wang
    Pengfei Song
    Xinying Liu
    Xingru He
    Ophthalmology and Therapy, 2024, 13 : 917 - 933