Semiconducting YBCO bolometers for uncooled IR detection

被引:15
|
作者
Almasri, M [1 ]
Butler, DP [1 ]
Celik-Butler, Z [1 ]
机构
[1] So Methodist Univ, Dept Elect Engn, Dallas, TX 75275 USA
关键词
uncooled infrared detection; yttrium barium copper oxide; bolometer;
D O I
10.1117/12.391744
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Amorphous semiconducting Y-Ba-Cu-O is attractive as the temperature sensitive element for uncooled LR bolometers and pyroelectric detectors. Thin films can be easily fabricated by RF magnetron sputtering at room temperature from a composite target. It is compatible with micromachining techniques for the fabrication of thermally isolated structures. As a bolometer, Y-Ba-Cu-O possesses a relatively high temperature coefficient of resistance of 3.5% K-1 near room temperature. This paper will present the IR characteristics of 40-mum x 40-mum microbolometer arrays fabricated in thermal isolation structures. These detectors are aimed at thermal imaging at 10-mum wavelength. Recently, self-supporting YBaCuO pixels have been developed. In this case, the Y-Ba-Cu-O thin film pixel requires no underlying bridge material to provide structural support. The Y-Ba-Cu-O thin film is supported solely by the electrode arms. Responsivity and detectivity greater than 4x10(3) V/W and 10(8) cmHz(1/2)/W respectively have been measured in these detectors. The development of large area 1.5-mm and 0.4-mm square YBaCuO bolometers for NASA's global warming studies in low-orbiting satellites will also be presented. These large area detectors require large optical bandwidths covering the 0.3-mum to 100-mum wavelength band.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [21] Semiconducting YBaCuO as infrared detecting bolometers
    Gray, J
    Çelik-Butler, Z
    Butler, DP
    Almasri, M
    INFRARED TECHNOLOGY AND APPLICATIONS XXIV, PTS 1-2, 1998, 3436 : 555 - 565
  • [22] How to get phonon noise limited uncooled bolometers?
    Guillet, B.
    Liu, S.
    Wu, S.
    Mechin, L.
    Adamo, C.
    Schlom, D. G.
    2015 INTERNATIONAL CONFERENCE ON NOISE AND FLUCTUATIONS (ICNF), 2015,
  • [23] Recent advances in manufacturing of miniaturized uncooled IR detection modules
    Kalinowski, Przemyslaw
    Mikolajczyk, Janusz
    Piotrowski, Adam
    Piotrowski, Jozef
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2019, 34 (03)
  • [24] YBCO hot-electron bolometers dedicated to THz detection and imaging: embedding issues
    Aurino, M.
    Kreisler, A. J.
    Tuerer, I.
    Martinez, A.
    Gensbittel, A.
    Degardin, A. F.
    9TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS 09), 2010, 234
  • [25] Linear arrays of uncooled poly SiGe microbolometers for IR detection
    De Moor, P
    Sedky, S
    Sabuncuoglu, D
    Van Hoof, C
    MICROMACHINED DEVICES AND COMPONENTS V, 1999, 3876 : 256 - 259
  • [26] Amorphous semiconducting Y-Ba-Cu-O: a silicon-compatible material for IR uncooled sensitive detection with microsecond response time
    Kreisler, Alain J.
    Jagtap, Vishal S.
    Degardin, Annick F.
    MILLIMETRE WAVE AND TERAHERTZ SENSORS AND TECHNOLOGY V, 2013, 8544
  • [27] COBALT-MANGANESE SEMICONDUCTING OXIDE BOLOMETERS
    BURKIN, AL
    SHEFMEL, IT
    SOVIET PHYSICS-SOLID STATE, 1960, 2 (02): : 267 - 274
  • [28] Antenna-Coupled MOSFET Bolometers for Uncooled THz Sensing
    Corcos, Dan
    Kaminski, Noam
    Shumaker, Evgeny
    Markish, Ofer
    Elad, Danny
    Morf, Thomas
    Drechsler, Ute
    Saha, Winnie Tatiana Silatsa
    Kull, Lukas
    Wood, Ken
    Pfeiffer, Ullrich R.
    Grzyb, Janusz
    IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY, 2015, 5 (06) : 902 - 913
  • [29] Mathematical modeling of the temperature dependence of the parameters of uncooled metal bolometers
    Grunin, VK
    JOURNAL OF OPTICAL TECHNOLOGY, 2001, 68 (12) : 952 - 955
  • [30] Algorithm for Estimating the Efficiency of Uncooled Bolometers Based on Metals and Their Alloys
    P. V. Vybornov
    M. V. Kabanov
    Yu. M. Andreev
    Russian Physics Journal, 2017, 59 : 1518 - 1520