Force analysis of single piece acrylic lens haptics to determine stability of Intraocular lens suture fixation

被引:0
|
作者
Patel, SN [1 ]
Sjaarda, RN [1 ]
Mahadevia, JP [1 ]
机构
[1] Wilmer Eye Inst, Baltimore, MD USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
268
引用
收藏
页码:U49 / U49
页数:1
相关论文
共 50 条
  • [1] Foldable acrylic intraocular lens with distended haptics for transscleral fixation
    Yaguchi, Saori
    Yaguchi, Shigeo
    Noda, Yoshiko
    Taguchi, Yoko
    Negishi, Kazuno
    Tsubota, Kazuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2047 - 2050
  • [2] Surgical technique for suture fixation of a single-piece hydrophilic acrylic intraocular lens in the absence of capsule support
    Oh, Hyun-Sub
    Chu, Young-Kwang
    Kwon, Oh-Woong
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (06): : 962 - 965
  • [3] Rotational stability of a single-piece toric acrylic intraocular lens
    Koshy, John J.
    Nishi, Yutaro
    Hirnschall, Nino
    Crnej, Alja
    Gangwani, Vinod
    Maurino, Vincenzo
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1665 - 1670
  • [4] Transscleral fixation of a single-piece hydrophilic foldable acrylic intraocular lens
    Taskapili, Muhittin
    Gulkilik, Gokhan
    Engin, Gunay
    Kocabora, Mehmet Selim
    Yilmazli, Cemil
    Ozsutcu, Mustafa
    Kucuksahin, Hasan
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2007, 42 (02): : 256 - 261
  • [5] Comparison of stability between a modular intraocular lens system and a single-piece hydrophobic acrylic intraocular lens
    SooHoo, Jeffrey R.
    Lane, Stephen S.
    Cionni, Robert J.
    Berdahl, John P.
    Sussman, Glenn R.
    Kahook, Malik Y.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1821 - 1825
  • [6] Suture fixation of a foldable acrylic intraocular lens for ectopia lentis
    Packer, M
    Fine, IH
    Hoffman, RS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (01): : 182 - 185
  • [7] Breakage of the haptic of a single-piece acrylic intraocular lens after transscleral fixation
    Choi, Suk Kyue
    Kim, Jin Hyoung
    Lee, Doh
    Lee, Jong Hyun
    ACTA OPHTHALMOLOGICA, 2010, 88 (08) : e346 - e347
  • [8] Haptic Breakage after Transscleral Fixation of a Single-Piece Acrylic Intraocular Lens
    Tanaka, Hiroki
    Fujinami, Kaoru
    Watanabe, Ken
    Noda, Toru
    Akiyama, Kunihiko
    CASE REPORTS IN OPHTHALMOLOGY, 2014, 5 (02): : 212 - 216
  • [9] Intrascleral fixation of intraocular lens haptics: histological advantages in a comparison with scleral suture fixation in rabbits
    Hanemoto, Tsukasa
    Mukai, Koichiro
    Matsushima, Hiroyuki
    Senoo, Tadashi
    Kozawa, Tadahiko
    Takahashi, Yasuhiro
    Kakizaki, Hirohiko
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (03) : 465 - 472
  • [10] Intrascleral fixation of intraocular lens haptics: histological advantages in a comparison with scleral suture fixation in rabbits
    Tsukasa Hanemoto
    Koichiro Mukai
    Hiroyuki Matsushima
    Tadashi Senoo
    Tadahiko Kozawa
    Yasuhiro Takahashi
    Hirohiko Kakizaki
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 465 - 472