Three dimensional subsurface elemental identification of minerals using confocal micro-X-ray fluorescence and micro-X-ray computed tomography

被引:16
|
作者
Cordes, Nikolaus L. [1 ]
Seshadri, Srivatsan [2 ]
Havrilla, George J. [3 ]
Yuan, Xiaoli [4 ]
Feser, Michael [2 ]
Patterson, Brian M. [1 ]
机构
[1] Los Alamos Natl Lab, Div Mat Sci & Technol, Polymers & Coatings Grp, Los Alamos, NM 87545 USA
[2] Carl Zeiss Xray Microscopy Inc, Pleasanton, CA 94588 USA
[3] Los Alamos Natl Lab, Div Chem, Los Alamos, NM 87545 USA
[4] Univ Queensland, Julius Kruttschnitt Mineral Res Ctr, Brisbane, Qld 4068, Australia
基金
美国国家科学基金会;
关键词
Confocal micro-X-ray fluorescence; Micro-X-ray computed tomography; Subsurface particle analysis; PLASMA-MASS SPECTROMETRY; OBJECTS; QUANTIFICATION; SYSTEMS; COPPER; LAYERS; XRF;
D O I
10.1016/j.sab.2014.12.006
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Current non-destructive elemental characterization methods, such as scanning electron microscopy-based energy dispersive spectroscopy (SEM-EDS) and micro-X-ray fluorescence spectroscopy (MXRF), are limited to either elemental identification at the surface (SEM-EDS) or suffer from an inability to discriminate between surface or depth information (MXRF). Thus, a non-destructive elemental characterization of individual embedded particles beneath the surface is impossible with either of these techniques. This limitation can be overcome by using laboratory-based 3D confocal micro-X-ray fluorescence spectroscopy (confocal MXRF). This technique utilizes focusing optics on the X-ray source and detector which allows for spatial discrimination in all three dimensions. However, the voxel-by-voxel serial acquisition of a 3D elemental scan can be very time-intensive (similar to 1 to 4 weeks) if it is necessary to locate individual embedded particles of interest. As an example, if each point takes a 5 s measurement time, a small volume of 50 x 50 x 50 pixels leads to an acquisition time of approximately 174 h, not including sample stage movement time. Initially screening the samples for particles of interest using micro-X-ray computed tomography (micro-CT) can significantly reduce the time required to spatially locate these particles. Once located, these individual particles can be elementally characterized with confocal MXRF. Herein, we report the elemental identification of high atomic number surface and subsurface particles embedded in a mineralogical matrix by coupling micro-CT and confocal MXRF. Synergistically, these two X-ray based techniques first rapidly locate and then elementally identify individual subsurface particles. Published by Elsevier B.V.
引用
收藏
页码:144 / 154
页数:11
相关论文
共 50 条
  • [21] Confocal three-dimensional micro-X-ray fluorescence spectroscopy used to retrieve the information covered in printed paper
    Sun, Xuepeng
    Zhang, Xiaoyun
    Wang, Xinyun
    Wang, Yabing
    Li, Yufei
    Peng, Shiqi
    Shao, Shangkun
    Liu, Zhiguo
    Shang, Hongzhong
    Sun, Tianxi
    [J]. X-RAY SPECTROMETRY, 2020, 49 (02) : 267 - 273
  • [22] Study on Zn relative concentration and chemical state in broilers duodenum by micro-X-ray fluorescence and micro-X-ray absorption fine structure
    Liu, Hua-Wei
    Liu, Da-Sen
    Zheng, Li-Xin
    [J]. LIVESTOCK SCIENCE, 2014, 161 : 101 - 108
  • [23] Detection of visible and latent fingerprints by micro-X-ray fluorescence
    Worley, Christopher G.
    Wiltshire, Sara S.
    Miller, Thomasin C.
    Havrilla, George J.
    Majidi, Vahid
    [J]. POWDER DIFFRACTION, 2006, 21 (02) : 136 - 139
  • [24] MICRO-X-RAY FLUORESCENCE ANALYSIS IN THE ELECTRON-MICROSCOPE
    POZSGAI, I
    [J]. MAGYAR KEMIAI FOLYOIRAT, 1989, 95 (03): : 124 - 130
  • [25] SIZE EFFECTS IN GLASS FRAGMENT IDENTIFICATION BY MICRO-X-RAY FLUORESCENCE ANALYSIS
    POZSGAI, I
    BARNA, A
    TOTH, P
    [J]. SCANNING, 1990, 12 (01) : 53 - 56
  • [26] Quantitative analysis of single aerosol particles with confocal micro-X-ray fluorescence spectrometer
    Sun, Tianxi
    Liu, Zhiguo
    Li, Yude
    Lin, Xiaoyan
    Wang, Guangfu
    Zhu, Guanghua
    Xu, Qing
    Luo, Ping
    Pan, Qiuli
    Liu, Hui
    Ding, Xunliang
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 295 - 297
  • [27] Investigation of polycapillary half lenses for quantitative confocal micro-X-ray fluorescence analysis
    Iro, Michael
    Ingerle, Dieter
    Radtke, Martin
    Buzanich, Ana Guilherme
    Kregsamer, Peter
    Streli, Christina
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 1376 - 1384
  • [28] Imaging brine and air inclusions in sea ice using micro-X-ray computed tomography
    Obbard, Rachel W.
    Troderman, Gregory
    Baker, Ian
    [J]. JOURNAL OF GLACIOLOGY, 2009, 55 (194) : 1113 - 1115
  • [29] Evaluation of Collateral Source Characteristics With 3-Dimensional Analysis Using Micro-X-Ray Computed Tomography
    Arima, Yuichiro
    Hokimoto, Seiji
    Tabata, Noriaki
    Nakagawa, Osamu
    Oshima, Asahi
    Matsumoto, Yosuke
    Sato, Takahiro
    Mukunoki, Toshifumi
    Otani, Jun
    Ishii, Masanobu
    Uchikawa, Michie
    Yamamoto, Eiichiro
    Izumiya, Yasuhiro
    Kaikita, Koichi
    Ogawa, Hisao
    Nishiyama, Koichi
    Tsujita, Kenichi
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (06):
  • [30] High-throughput screening with micro-x-ray fluorescence
    Havrilla, GJ
    Miller, TC