Novel Bending Fatigue Testing of Small Medical Device Cables

被引:0
|
作者
Zhang, Haitao [1 ]
Li, Bernard [1 ]
机构
[1] Medtronic, 7000 Cent Ave NE, Minneapolis, MN 55432 USA
关键词
Fatigue; Cable; Medical device; Testing; Neuromodulation; DEEP BRAIN-STIMULATION; MOVEMENT-DISORDERS; EFFICACY; SAFETY;
D O I
10.1007/978-3-319-21455-9_16
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Neuromodulation is among one of the fastest-growing areas of the medical device industry. Neuro stimulators are being used to provide therapies to patients with chronic pain, movement disorders, overactive bladders, and psychiatric disorder symptoms. In these therapies, well-controlled stimulation current is delivered to the target nerves through implantable leads. The implantable leads must have sufficient fatigue durability to last for many years of implantation. The implantable leads are composed of insulation polymer jackets and conductor coils/cables. Conductor cables are generally very small and made from MP35N alloys (Co-35Ni-20Cr-10Mo). These conductor cables are more susceptible to fatigue failure than the insulation polymer jackets. A novel bending fatigue testing method was developed and used to test small medical device cables. 1x7 standard MP35N and low Ti MP35N cables are tested. The generalized S-N curve, in the form of curvature amplitude as a function of cycle to failure was obtained. The results show that low Ti MP35N cable has better fatigue performance than the standard MP35N cable. A SEM image of fractured surface shows that cable fatigue is dominated by crack initiation. The crack initiation is induced by shear deformation. This is a typical crack initiation mechanism under high plasticity deformation.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [31] DEVICE FOR TESTING THIN SPRING STRIP FOR BENDING
    KALACHEV, IB
    DROBYSHEV, BA
    ARKHAROVA, VD
    MOROGOV, FZ
    INDUSTRIAL LABORATORY, 1979, 45 (03): : 352 - 353
  • [32] Investigation on the Design and Experimental Application of Novel Fatigue Testing Device for Esophagus Stent
    Gu Xingzhong
    Liu Lei
    Ni Zhonghua
    Cheng Jie
    Long Zhihong
    2013 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2013, : 407 - 411
  • [33] FATIGUE TESTING DEVICE FOR NONCIRCULAR SPECIMENS
    RUDNITSKII, VI
    INDUSTRIAL LABORATORY, 1958, 24 (04): : 557 - 558
  • [34] A DEVICE FOR BENDING-FATIGUE TESTS OF CEMENT MATERIALS
    GLADKOV, VS
    KALKO, YA
    INDUSTRIAL LABORATORY, 1960, 26 (10): : 1362 - 1363
  • [35] DEVICE FOR FATIGUE TESTING POROUS MATERIALS
    KOTOV, VA
    SHCHEKANENKO, RA
    INDUSTRIAL LABORATORY, 1979, 45 (12): : 1402 - 1404
  • [36] A new device for fretting fatigue testing
    G. H. Majzoobi
    R. Hojjati
    M. Nematian
    E. Zalnejad
    A. R. Ahmadkhani
    E. Hanifepoor
    Transactions of the Indian Institute of Metals, 2010, 63 : 493 - 497
  • [37] A new device for fretting fatigue testing
    Majzoobi, G. H.
    Hojjati, R.
    Nematian, M.
    Zalnejad, E.
    Ahmadkhani, A. R.
    Hanifepoor, E.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2010, 63 (2-3) : 493 - 497
  • [38] DEVICE FOR TESTING METALS FOR THERMOMECHANICAL FATIGUE
    IVANOV, AI
    TRAKHTEN.BF
    INDUSTRIAL LABORATORY, 1968, 34 (06): : 877 - &
  • [39] DEVICE FOR FATIGUE TESTING OF WIRE FITTINGS
    GORODNIS.FM
    FINK, VK
    INDUSTRIAL LABORATORY, 1964, 30 (05): : 760 - &
  • [40] Automated Testing of the Medical Device
    Roja, G. P.
    Sarala, S. M.
    2017 2ND IEEE INTERNATIONAL CONFERENCE ON RECENT TRENDS IN ELECTRONICS, INFORMATION & COMMUNICATION TECHNOLOGY (RTEICT), 2017, : 217 - 220