Automated hollow-fiber liquid-phase microextraction followed by liquid chromatography with mass spectrometry for the determination of benzodiazepine drugs in biological samples

被引:30
|
作者
Nazaripour, Ali [1 ]
Yamini, Yadollah [1 ]
Ebrahimpour, Behnam [1 ]
Fasihi, Javad [2 ]
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
[2] AEOI, Nucl Sci & Technol Res Inst, Tehran, Iran
关键词
Automated extraction; Benzodiazepines; Hollow fiber; Liquid chromatography; Microextraction; IMMISCIBLE ORGANIC-SOLVENTS; GAS-CHROMATOGRAPHY; AROMATIC-AMINES; WATER SAMPLES; GC-MS; EXTRACTION; METABOLITES; FLUIDS; URINE; PESTICIDES;
D O I
10.1002/jssc.201600015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, two-phase hollow-fiber liquid-phase microextraction and three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents were compared for extraction of oxazepam and Lorazepam. Separations were performed on a liquid chromatography with mass spectrometry instrument. Under optimal conditions, three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents has a better extraction efficiency. In a urine sample, for three-phase hollow fiber liquid-phase microextraction based on two immiscible organic solvents, the calibration curves were found to be linear in the range of 0.6-200 and 0.9-200 mu g L-1 and the limits of detection were 0.2 and 0.3 mu g L-1 for oxazepam and lorazepam, respectively. For two-phase hollow fiber liquid-phase microextraction, the calibration curves were found to be linear in the range of 1-200 and 1.5-200 mu g L-1 and the limits of detection were 0.3 and 0.5 mu g L-1 for oxazepam and lorazepam, respectively. In a urine sample, for three-phase hollow-fiber-based liquid-phase microextraction based on two immiscible organic solvents, relative standard deviations in the range of 4.2-4.5% and preconcentration factors in the range of 70-180 were obtained for oxazepam and lorazepam, respectively. Also for the two-phase hollow-fiber liquid-phase microextraction, preconcentration factors in the range of 101-257 were obtained for oxazepam and lorazepam, respectively.
引用
收藏
页码:2595 / 2603
页数:9
相关论文
共 50 条
  • [41] The mass transfer dynamics of hollow fiber liquid-phase microextraction and its application for rapid analysis of biological samples
    Cui, Shufen
    Ouyang, Gangfeng
    Duan, Guijiao
    Hou, Jinxing
    Luan, Tiangang
    Zhang, Xu
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1266 : 10 - 16
  • [42] Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry
    Antonia Garrido Frenich
    R. Romero-González
    José Luis Martínez Vidal
    R. Martínez Ocaña
    P. Baquero Feria
    Analytical and Bioanalytical Chemistry, 2011, 399 : 2043 - 2059
  • [43] Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry
    Garrido Frenich, Antonia
    Romero-Gonzalez, R.
    Martinez Vidal, Jose Luis
    Martinez Ocana, R.
    Baquero Feria, P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (06) : 2043 - 2059
  • [44] Determination of organic micropollutants in rainwater using hollow fiber membrane/liquid-phase microextraction combined with gas chromatography-mass spectrometry
    Basheer, C
    Balasubramanian, R
    Lee, HK
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1016 (01) : 11 - 20
  • [45] Determination of Barbiturates in Biological Specimens by Flat Membrane-Based Liquid-Phase Microextraction and Liquid Chromatography-Mass Spectrometry
    Zhu, Ruiqin
    Dong, Ying
    Cai, Xiangyang
    Huang, Chuixiu
    MOLECULES, 2019, 24 (08)
  • [46] Determination of tetrandrine and fangchinoline in plasma samples using hollow fiber liquid-phase microextraction combined with high-performance liquid chromatography
    Yang, Cailing
    Guo, Linyuan
    Liu, Xiaoyan
    Zhang, Haixia
    Liu, Mancang
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1164 (1-2) : 56 - 64
  • [47] Hollow-Fiber Liquid-Phase Microextraction in the Three-Phase Mode Practical Considerations
    Gjelstad, Astrid
    Taherkhani, Hamidreza
    Rasmussen, Knut Einar
    Pedersen-Bjergaard, Stig
    Majors, Ronald E.
    LC GC NORTH AMERICA, 2011, 29 (12) : 1038 - +
  • [48] Hollow fiber liquid phase microextraction combined with liquid chromatography-tandem mass spectrometry for the analysis of emerging contaminants in water samples
    Salvatierra-stamp, Vilma
    Muniz-Valencia, Roberto
    Jurado, Jose M.
    Ceballos-Magana, Silvia G.
    MICROCHEMICAL JOURNAL, 2018, 140 : 87 - 95
  • [49] Hollow-fiber Microextraction Combined with Hydrophilic Interaction Liquid Chromatography Mass Spectrometry for Analytical Determination of High Polarity Herbicides in Water
    Jayanta, Siripastr
    Leepipatpiboon, Natchanun
    CHIANG MAI JOURNAL OF SCIENCE, 2018, 45 (06): : 2381 - 2396
  • [50] Hollow fiber liquid-phase microextraction combined with supercritical fluid chromatography coupled to mass spectrometry for multiclass emerging contaminant quantification in water samples
    Vilma del Carmen Salvatierra-Stamp
    Silvia G. Ceballos-Magaña
    Norma Susana Pano-Farias
    José Belisario Leyva-Morales
    Kayim Pineda-Urbina
    Roberto Muñiz-Valencia
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2467 - 2479