Automated hollow-fiber liquid-phase microextraction followed by liquid chromatography with mass spectrometry for the determination of benzodiazepine drugs in biological samples

被引:30
|
作者
Nazaripour, Ali [1 ]
Yamini, Yadollah [1 ]
Ebrahimpour, Behnam [1 ]
Fasihi, Javad [2 ]
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
[2] AEOI, Nucl Sci & Technol Res Inst, Tehran, Iran
关键词
Automated extraction; Benzodiazepines; Hollow fiber; Liquid chromatography; Microextraction; IMMISCIBLE ORGANIC-SOLVENTS; GAS-CHROMATOGRAPHY; AROMATIC-AMINES; WATER SAMPLES; GC-MS; EXTRACTION; METABOLITES; FLUIDS; URINE; PESTICIDES;
D O I
10.1002/jssc.201600015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, two-phase hollow-fiber liquid-phase microextraction and three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents were compared for extraction of oxazepam and Lorazepam. Separations were performed on a liquid chromatography with mass spectrometry instrument. Under optimal conditions, three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents has a better extraction efficiency. In a urine sample, for three-phase hollow fiber liquid-phase microextraction based on two immiscible organic solvents, the calibration curves were found to be linear in the range of 0.6-200 and 0.9-200 mu g L-1 and the limits of detection were 0.2 and 0.3 mu g L-1 for oxazepam and lorazepam, respectively. For two-phase hollow fiber liquid-phase microextraction, the calibration curves were found to be linear in the range of 1-200 and 1.5-200 mu g L-1 and the limits of detection were 0.3 and 0.5 mu g L-1 for oxazepam and lorazepam, respectively. In a urine sample, for three-phase hollow-fiber-based liquid-phase microextraction based on two immiscible organic solvents, relative standard deviations in the range of 4.2-4.5% and preconcentration factors in the range of 70-180 were obtained for oxazepam and lorazepam, respectively. Also for the two-phase hollow-fiber liquid-phase microextraction, preconcentration factors in the range of 101-257 were obtained for oxazepam and lorazepam, respectively.
引用
收藏
页码:2595 / 2603
页数:9
相关论文
共 50 条
  • [31] Determination of Polycyclic Aromatic Hydrocarbons in Fresh Milk by Hollow Fiber Liquid-Phase Microextraction-Gas Chromatography Mass Spectrometry
    Sanagi, Mohd Marsin
    Loh, Saw Hong
    Ibrahim, Wan Aini Wan
    Hasan, Mohamed Noor
    Enein, Hassan Y. Aboul
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2013, 51 (02) : 112 - 116
  • [32] Determination of polychlorinated biphenyls in water using dynamic hollow fiber liquid-phase microextraction and gas chromatography-mass spectrometry
    Li, Guanhua
    Zhang, Lijun
    Zhang, Zhanen
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1204 (01) : 119 - 122
  • [33] Determination of ring-substituted amphetamines through automated online hollow fiber liquid-phase microextraction-liquid chromatography
    Luis Felipe Rodríguez Cabal
    Deyber Arley Vargas Medina
    Jose Luiz Costa
    Fernando Mauro Lanças
    Álvaro José Santos-Neto
    Analytical and Bioanalytical Chemistry, 2019, 411 : 7889 - 7897
  • [34] Determination of ring-substituted amphetamines through automated online hollow fiber liquid-phase microextraction-liquid chromatography
    Rodriguez Cabal, Luis Felipe
    Vargas Medina, Deyber Arley
    Costa, Jose Luiz
    Lancas, Fernando Mauro
    Santos-Neto, Alvaro Jose
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (29) : 7889 - 7897
  • [35] Determination of carbamate pesticides in water and fruit samples using carbon nanotube reinforced hollow fiber liquid-phase microextraction followed by high performance liquid chromatography
    Zhao, Guangying
    Wang, Chun
    Wu, Qiuhua
    Wang, Zhi
    ANALYTICAL METHODS, 2011, 3 (06) : 1410 - 1417
  • [36] Hollow-fiber liquid-phase microextraction for the determination of pesticides and metabolites in soils and water samples using HPLC and fluorescence detection
    Asensio-Ramos, Maria
    Hernandez-Borges, Javier
    Gonzalez-Hernandez, Guillermo
    Angel Rodriguez-Delgado, Miguel
    ELECTROPHORESIS, 2012, 33 (14) : 2184 - 2191
  • [37] Liquid-phase microextraction combined with hollow fiber as a sample preparation technique prior to gas chromatography/mass spectrometry
    Zhao, LM
    Lee, HK
    ANALYTICAL CHEMISTRY, 2002, 74 (11) : 2486 - 2492
  • [38] Mesoporous carbon reinforced hollow fiber liquid-phase microextraction for the enrichment of phenylurea herbicides followed by their determination with high performance liquid chromatography
    Wu, Qiuhua
    Zhao, Ying
    Wang, Chun
    Sun, Meng
    Ma, Xiaoxing
    Wang, Zhi
    ANALYTICAL METHODS, 2015, 7 (03) : 901 - 908
  • [39] Liquid-phase microextraction combined with liquid chromatography-mass spectrometry. Extraction from small volumes of biological samples
    Halvorsen, TG
    Pedersen-Bjergaard, S
    Reubsaet, JLE
    Rasmussen, KE
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (17) : 1520 - 1526
  • [40] Hollow-Fiber Liquid-Phase Microextraction Combined with High-Performance Liquid Chromatography for Analysis of Melamine in Milk Products
    Wang, G. -Y.
    Chen, J.
    Shi, Y. -P.
    ACTA CHROMATOGRAPHICA, 2010, 22 (02) : 307 - 321