Automated hollow-fiber liquid-phase microextraction followed by liquid chromatography with mass spectrometry for the determination of benzodiazepine drugs in biological samples
被引:30
|
作者:
Nazaripour, Ali
论文数: 0引用数: 0
h-index: 0
机构:
Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, IranTarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
Nazaripour, Ali
[1
]
论文数: 引用数:
h-index:
机构:
Yamini, Yadollah
[1
]
Ebrahimpour, Behnam
论文数: 0引用数: 0
h-index: 0
机构:
Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, IranTarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
Ebrahimpour, Behnam
[1
]
Fasihi, Javad
论文数: 0引用数: 0
h-index: 0
机构:
AEOI, Nucl Sci & Technol Res Inst, Tehran, IranTarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
Fasihi, Javad
[2
]
机构:
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
[2] AEOI, Nucl Sci & Technol Res Inst, Tehran, Iran
In this study, two-phase hollow-fiber liquid-phase microextraction and three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents were compared for extraction of oxazepam and Lorazepam. Separations were performed on a liquid chromatography with mass spectrometry instrument. Under optimal conditions, three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents has a better extraction efficiency. In a urine sample, for three-phase hollow fiber liquid-phase microextraction based on two immiscible organic solvents, the calibration curves were found to be linear in the range of 0.6-200 and 0.9-200 mu g L-1 and the limits of detection were 0.2 and 0.3 mu g L-1 for oxazepam and lorazepam, respectively. For two-phase hollow fiber liquid-phase microextraction, the calibration curves were found to be linear in the range of 1-200 and 1.5-200 mu g L-1 and the limits of detection were 0.3 and 0.5 mu g L-1 for oxazepam and lorazepam, respectively. In a urine sample, for three-phase hollow-fiber-based liquid-phase microextraction based on two immiscible organic solvents, relative standard deviations in the range of 4.2-4.5% and preconcentration factors in the range of 70-180 were obtained for oxazepam and lorazepam, respectively. Also for the two-phase hollow-fiber liquid-phase microextraction, preconcentration factors in the range of 101-257 were obtained for oxazepam and lorazepam, respectively.
机构:
Univ Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
Univ Teknol Malaysia, Ibnu Sina Inst Fundamental Sci Studies, Nanotechnol Res Alliance, Johor Baharu 81310, Johor, MalaysiaUniv Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
Sanagi, Mohd Marsin
Loh, Saw Hong
论文数: 0引用数: 0
h-index: 0
机构:
Univ Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
Univ Malaysia Terengganu, Fac Sci & Technol, Dept Chem Sci, Kuala Terengganu 21030, MalaysiaUniv Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
Loh, Saw Hong
Ibrahim, Wan Aini Wan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
Univ Teknol Malaysia, Ibnu Sina Inst Fundamental Sci Studies, Nanotechnol Res Alliance, Johor Baharu 81310, Johor, MalaysiaUniv Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
Ibrahim, Wan Aini Wan
Hasan, Mohamed Noor
论文数: 0引用数: 0
h-index: 0
机构:
Univ Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
Univ Teknol Malaysia, Ibnu Sina Inst Fundamental Sci Studies, Nanotechnol Res Alliance, Johor Baharu 81310, Johor, MalaysiaUniv Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
Hasan, Mohamed Noor
Enein, Hassan Y. Aboul
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Ctr, Pharmaceut & Drug Ind Res Div, Dept Pharmaceut & Med Chem, Cairo 12311, EgyptUniv Teknol Malaysia, Fac Sci, Dept Chem, Johor Baharu 81310, Johor, Malaysia
机构:
Univ La Laguna, Dept Quim Analit Nutr & Bromatol, Fac Quim, San Cristobal la Laguna 38206, Tenerife, SpainUniv La Laguna, Dept Quim Analit Nutr & Bromatol, Fac Quim, San Cristobal la Laguna 38206, Tenerife, Spain
Asensio-Ramos, Maria
Hernandez-Borges, Javier
论文数: 0引用数: 0
h-index: 0
机构:
Univ La Laguna, Dept Quim Analit Nutr & Bromatol, Fac Quim, San Cristobal la Laguna 38206, Tenerife, SpainUniv La Laguna, Dept Quim Analit Nutr & Bromatol, Fac Quim, San Cristobal la Laguna 38206, Tenerife, Spain
Hernandez-Borges, Javier
Gonzalez-Hernandez, Guillermo
论文数: 0引用数: 0
h-index: 0
机构:
Univ La Laguna, Dept Quim Analit Nutr & Bromatol, Fac Quim, San Cristobal la Laguna 38206, Tenerife, SpainUniv La Laguna, Dept Quim Analit Nutr & Bromatol, Fac Quim, San Cristobal la Laguna 38206, Tenerife, Spain
Gonzalez-Hernandez, Guillermo
Angel Rodriguez-Delgado, Miguel
论文数: 0引用数: 0
h-index: 0
机构:
Univ La Laguna, Dept Quim Analit Nutr & Bromatol, Fac Quim, San Cristobal la Laguna 38206, Tenerife, SpainUniv La Laguna, Dept Quim Analit Nutr & Bromatol, Fac Quim, San Cristobal la Laguna 38206, Tenerife, Spain
机构:
Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China
Chinese Acad Sci, Grad Univ, Beijing 100039, Peoples R ChinaChinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China
Wang, G. -Y.
Chen, J.
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R ChinaChinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China
Chen, J.
Shi, Y. -P.
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R ChinaChinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China