Automated hollow-fiber liquid-phase microextraction followed by liquid chromatography with mass spectrometry for the determination of benzodiazepine drugs in biological samples

被引:30
|
作者
Nazaripour, Ali [1 ]
Yamini, Yadollah [1 ]
Ebrahimpour, Behnam [1 ]
Fasihi, Javad [2 ]
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
[2] AEOI, Nucl Sci & Technol Res Inst, Tehran, Iran
关键词
Automated extraction; Benzodiazepines; Hollow fiber; Liquid chromatography; Microextraction; IMMISCIBLE ORGANIC-SOLVENTS; GAS-CHROMATOGRAPHY; AROMATIC-AMINES; WATER SAMPLES; GC-MS; EXTRACTION; METABOLITES; FLUIDS; URINE; PESTICIDES;
D O I
10.1002/jssc.201600015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, two-phase hollow-fiber liquid-phase microextraction and three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents were compared for extraction of oxazepam and Lorazepam. Separations were performed on a liquid chromatography with mass spectrometry instrument. Under optimal conditions, three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents has a better extraction efficiency. In a urine sample, for three-phase hollow fiber liquid-phase microextraction based on two immiscible organic solvents, the calibration curves were found to be linear in the range of 0.6-200 and 0.9-200 mu g L-1 and the limits of detection were 0.2 and 0.3 mu g L-1 for oxazepam and lorazepam, respectively. For two-phase hollow fiber liquid-phase microextraction, the calibration curves were found to be linear in the range of 1-200 and 1.5-200 mu g L-1 and the limits of detection were 0.3 and 0.5 mu g L-1 for oxazepam and lorazepam, respectively. In a urine sample, for three-phase hollow-fiber-based liquid-phase microextraction based on two immiscible organic solvents, relative standard deviations in the range of 4.2-4.5% and preconcentration factors in the range of 70-180 were obtained for oxazepam and lorazepam, respectively. Also for the two-phase hollow-fiber liquid-phase microextraction, preconcentration factors in the range of 101-257 were obtained for oxazepam and lorazepam, respectively.
引用
收藏
页码:2595 / 2603
页数:9
相关论文
共 50 条
  • [1] Hollow-fiber liquid-phase microextraction and gas chromatography-mass spectrometry of barbiturates in whole blood samples
    de Almeida, Rafael Menck
    de Lima, Diogenes Saulo
    Seulin, Saskia Carolina
    Leyton, Vilma
    Pasqualucci, Carlos Augusto
    Munoz, Daniel Romero
    Osselton, Michael David
    Yonamine, Mauricio
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (23) : 3361 - 3368
  • [2] Determination of antidepressants in whole blood using hollow-fiber liquid-phase microextraction and gas chromatography–mass spectrometry
    Marcelo Filonzi dos Santos
    Caio Caleiras Ferri
    Saskia Carolina Seulin
    Vilma Leyton
    Carlos Augusto Gonçalves Pasqualucci
    Daniel Romero Muñoz
    Mauricio Yonamine
    Forensic Toxicology, 2014, 32 : 214 - 224
  • [3] Hollow-Fiber Liquid-Phase Microextraction Followed by Gas Chromatography Flame Ionization Detection for the Determination of Amitraz in Honey and Water Samples
    Yadollah Yamini
    Mohammad Faraji
    Mahnaz Ghambarian
    Food Analytical Methods, 2015, 8 : 758 - 766
  • [4] Hollow-Fiber Liquid-Phase Microextraction Followed by Gas Chromatography Flame Ionization Detection for the Determination of Amitraz in Honey and Water Samples
    Yamini, Yadollah
    Faraji, Mohammad
    Ghambarian, Mahnaz
    FOOD ANALYTICAL METHODS, 2015, 8 (03) : 758 - 766
  • [5] Determination of antidepressants in whole blood using hollow-fiber liquid-phase microextraction and gas chromatography-mass spectrometry
    dos Santos, Marcelo Filonzi
    Ferri, Caio Caleiras
    Seulin, Saskia Carolina
    Leyton, Vilma
    Goncalves Pasqualucci, Carlos Augusto
    Munoz, Daniel Romero
    Yonamine, Mauricio
    FORENSIC TOXICOLOGY, 2014, 32 (02) : 214 - 224
  • [6] Simultaneous derivatization and extraction of nitrophenols in soil and rain samples using modified hollow-fiber liquid-phase microextraction followed by gas chromatography–mass spectrometry
    Hamid Reza Sobhi
    Ali Esrafili
    Hadi Farahani
    Mitra Gholami
    Mohammad Mehdi Baneshi
    Environmental Monitoring and Assessment, 2013, 185 : 9055 - 9065
  • [7] Automated hollow-fiber liquid-phase microextraction coupled with liquid chromatography/tandem mass spectrometry for the analysis of aflatoxin M1 in milk
    Huang, Siming
    Hu, Du
    Wang, Ying
    Zhu, Fang
    Jiang, Ruifen
    Ouyang, Gangfeng
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1416 : 137 - 140
  • [8] Nonequilibrium hollow-fiber liquid-phase microextraction with in situ derivatization for the measurement of triclosan in aqueous samples by gas chromatography–mass spectrometry
    Ru-Song Zhao
    Jin-Peng Yuan
    Hai-Fang Li
    Xu Wang
    Ting Jiang
    Jin-Ming Lin
    Analytical and Bioanalytical Chemistry, 2007, 387 : 2911 - 2915
  • [9] Determination of triphenylphosphine oxide in active pharmaceutical ingredients by hollow-fiber liquid-phase microextraction followed by reversed-phase liquid chromatography
    Richoll, Stephen M.
    Colon, Ivelisse
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 147 - 153
  • [10] Hollow-fiber liquid-phase microextraction for the determination of natural and synthetic estrogens in milk samples
    Socas-Rodriguez, Barbara
    Asensio-Ramos, Maria
    Hernandez-Borges, Javier
    Angel Rodriguez-Delgado, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1313 : 175 - 184