Comparison between small radiation therapy electron beams collimated by Cerrobend and tubular applicators

被引:6
|
作者
Di Venanzio, Cristina [1 ]
Marinelli, Marco [1 ]
Tonnetti, Alessia [1 ]
Verona-Rinati, Gianluca [1 ]
Bagala, Paolo [2 ]
Falco, Maria Daniela [2 ]
Guerra, Antonio Stefano [3 ]
Pimpinella, Maria [3 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Ingn Ind, Ist Nazl Fis Nucl, I-00133 Rome, Italy
[2] Tor Vergata Univ Gen Hosp, Dept Diagnost Imaging Mol Imaging Intervent Radio, Rome, Italy
[3] ENEA INMRI CR Casaccia, Ist Nazl Metrol Radiaz Ionizzanti, Rome, Italy
来源
关键词
Cerrobend; tubular applicators; diamond; radiation therapy; small electron beams; DIAMOND DETECTOR; ENERGY;
D O I
10.1120/jacmp.v16i1.5186
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare the dosimetric properties of small field electron beams shaped by circular Cerrobend blocks and stainless steel tubular applicators. Percentage depth dose curves, beam profiles, and output factors of small-size circular fields from 2 to 5 cm diameter, obtained either by tubular applicators and Cerrobend blocks, were measured for 6, 10, and 15 MeV electron beam energies. All measurements were performed using a PTW microDiamond 60019 premarket prototype. An overall similar behavior between the two collimating systems can be observed in terms of PDD and beam profiles. However, Cerrobend collimators produce a higher bremsstrahlung background under irradiation with high-energy electrons. In such irradiation condition, larger output factors are observed for tubular applicators. Similar dosimetric properties are observed using circular Cerrobend blocks and stainless steel tubular applicators at lower beam energies. However, Cerrobend collimators allow the delivery of specific beam shapes, conformed to the target area. On the other hand, in high-energy irradiation conditions, tubular applicators produce a lower bremsstrahlung contribution, leading to lower doses outside the target volume. In addition, the higher output factors observed at high energies for tubular applicators lead to reduced treatment times.
引用
收藏
页码:329 / 335
页数:7
相关论文
共 50 条
  • [21] Magnetic-Modulated Radiation Therapy with High Energy Electron Beams
    Chen, M.
    Ma, L.
    Gu, X.
    Lu, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E372 - E373
  • [22] Increasing the Efficiency of Target Irradiation with Photon and Electron Beams in Radiation Therapy
    A. V. Belousov
    A. B. Plotnikov
    A. P. Chernyaev
    V. I. Shvedunov
    Instruments and Experimental Techniques, 2003, 46 : 828 - 831
  • [23] Increasing the efficiency of target irradiation with photon and electron beams in radiation therapy
    Belousov, AV
    Plotnikov, AB
    Chernyaev, AP
    Shvedunov, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2003, 46 (06) : 828 - 831
  • [24] Postmastectomy electron beams radiation therapy (PMERT) : long term results
    Sami, Souidi
    Loap, Pierre
    Fourquet, Alain
    Kirova, Youlia M.
    CANCER RESEARCH, 2023, 83 (05)
  • [25] COMPUTED DOSIMETRY OF SCANNED ELECTRON AND PHOTON BEAMS FOR RADIATION-THERAPY
    BRAHME, A
    NAFSTADIUS, P
    MEDICAL PHYSICS, 1984, 11 (03) : 381 - 381
  • [26] A Monte Carlo investigation of fluence profiles collimated by an electron specific MLC during beam delivery for modulated electron radiation therapy
    Deng, J
    Lee, MC
    Ma, CM
    MEDICAL PHYSICS, 2002, 29 (11) : 2472 - 2483
  • [27] MICRODOSIMETRIC COMPARISON OF SCANNED AND CONVENTIONAL PROTON BEAMS USED IN RADIATION THERAPY
    Dicello, John F.
    Gersey, Bradford B.
    Gridley, Daila S.
    Coutrakon, George B.
    Lesyna, David
    Pisacane, Vincent L.
    Robertson, James B.
    Schulte, Reinhard W.
    Slater, Jerry D.
    Wroe, Andrew J.
    Slater, James M.
    RADIATION PROTECTION DOSIMETRY, 2011, 143 (2-4) : 513 - 518
  • [28] HIGH-DOSE SPATIALLY FRACTIONATED GRID RADIATION THERAPY (SFGRT): A COMPARISON OF TREATMENT OUTCOMES WITH CERROBEND VS. MLC SFGRT
    Neuner, Geoffrey
    Mohiuddin, Majid M.
    Vander Walde, Noam
    Goloubeva, Olga
    Ha, Jonathan
    Yu, Cedric X.
    Regine, William F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1642 - 1649
  • [29] RADIATION DOSE DELIVERY FOR TOTAL SKIN ELECTRON THERAPY (TSET) WITH LOW ENERGY ELECTRON BEAMS
    Krishnamurthy, K.
    Davis, C. A.
    Ravichandran, R.
    Sivakumar, S. S.
    Mohanti, B. K.
    JOURNAL OF MEDICAL PHYSICS, 2005, 30 (02) : 66 - 70
  • [30] TUBULAR LYSOSOMES - COMPARISON BETWEEN LIVING CELLS AND ELECTRON-MICROSCOPY