Temporal Performance of Laplacian Eigenmaps and 3D Conduction Velocity in Detecting Ischemic Stress

被引:7
|
作者
Good, Wilson W. [1 ]
Erem, Burak [2 ,3 ]
Zenger, Brian [1 ]
Coll-Font, Jaume [3 ]
Brooks, Dana H. [4 ]
MacLeod, Rob S. [1 ]
机构
[1] Univ Utah, Sci Comp & Imaging Inst, Biomed Engn, Salt Lake City, UT USA
[2] TrueMotion, Boston, MA USA
[3] Boston Childrens Hosp, Computat Radiol Lab, Boston, MA USA
[4] Northeastern Univ, SPIRAL Grp, ECE Dept, Boston, MA 02115 USA
关键词
VENTRICULAR ARRHYTHMIAS; ISOLATED PORCINE; MYOCARDIUM;
D O I
10.1016/j.jelectrocard.2018.08.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial ischemia has a complex and time-varying electrocardiographic signature that is used to diagnose and stratify severity. Despite the ubiquitous clinical use of the ECG to detect ischemia, the sensitivity and specificity of ECG based detection of myocardial ischemia are still inadequate. Purpose: The purpose of this study was to compare, using animal models, the performance of several traditional ECG-based metrics for detecting acute ischemia against two novel metrics, the Laplacian Eigenmap (LE) parameters and a three-dimensional estimate of Conduction Velocity (CV). Methods: LE is a machine learning technique that reduces the dimensions of simultaneously recorded time signals using a non-linear embedding followed by an singular value decomposition to represent each multichannel recording as a single trajectory on a manifold. Perturbations in the trajectories suggest the presence of myocardial ischemia. CV was computed using a tetrahedral mesh created from the electrode locations of transmural plunge needles. To validate the results, we used electrograms collected over 95 episodes of acutely induced myocardial ischemia in 15 canine and 2 porcine subjects. The LE and CV metrics were compared against traditional metrics derived from the ST segment, the T wave, the QRS of the same electrograms. The response time and robustness of each metric was quantified using parameters we defined as time to threshold (ITT) and contrast ratio (CR). Results: The temporal performance of the metrics evaluated throughout the ischemic episodes showed a consistent relationship; the LE metrics changed earlier than those from the T wave, which were followed by those from the ST segment, and finally from the QRS. The CV results showed median drops in conduction velocity throughout the perfusion bed of more than 23% in canines and over 12% during half of the induced ischemia episodes in swine. The other half of the episodes in swine produced a 76% drop. Conclusions: Our results suggest that the LE metric is more sensitive to acute ischemia than traditional single parameters used in previous studies, likely because it incorporates the entire QRST across multiple electrodes in a way that captures their most salient features in a low-dimensional space. The estimates of conduction velocity suggest substantial, in some cases dramatic slowing of the spread of activation, a finding that is not surprising but has not been documented in such three-dimensional detail before. The experiments and these new metrics provide a means to both explore details of the acute ischemic response not available from humans and suggest a path to translate this knowledge into improvements in clinical scoring of ischemia. Published by Elsevier Inc.
引用
收藏
页码:S116 / S120
页数:5
相关论文
共 50 条
  • [21] BEM Analysis of 3D Heat Conduction in 3D Thin Anisotropic Media
    Shiah, Y. C.
    Lee, Y. M.
    Wang, Chi-Chang
    CMC-COMPUTERS MATERIALS & CONTINUA, 2013, 33 (03): : 229 - 255
  • [22] Diastolic function with 3D three-directional velocity encoded MRI in patients with ischemic cardiomyopathy
    Brandts A.
    Bertini M.
    van Dijk E.J.
    Delgado V.
    Siebelink H.J.
    Bax J.J.
    Roos A.
    Westenberg J.J.M.
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [23] 3D Velocity Quantification in the Heart: Improvements by 3D PC-SSFP
    Rolf, Marijn P.
    Hofman, Mark B. M.
    Kuijer, Joost P. A.
    van Rossum, Albert C.
    Heethaar, Rob M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 947 - 955
  • [24] A 3D Laplacian-Driven Parametric Deformable Model
    Shen, Tian
    Huang, Xiaolei
    Li, Hongsheng
    Kim, Edward
    Zhang, Shaoting
    Huang, Junzhou
    2011 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2011, : 279 - 286
  • [25] 3D Steganalysis Using Laplacian Smoothing at Various Levels
    Li, Zhenyu
    Liu, Fenlin
    Bors, Adrian G.
    CLOUD COMPUTING AND SECURITY, PT VI, 2018, 11068 : 223 - 232
  • [26] Efficient Parallel Algorithms for 3D Laplacian Smoothing on the GPU
    Xiao, Lei
    Yang, Guoxiang
    Zhao, Kunyang
    Mei, Gang
    APPLIED SCIENCES-BASEL, 2019, 9 (24):
  • [27] 3D CAD model retrieval with perturbed Laplacian spectra
    Zhu, Kunpeng
    Wong, Yoke San
    Loh, Han Tong
    Lu, Wen Feng
    COMPUTERS IN INDUSTRY, 2012, 63 (01) : 1 - 11
  • [28] On the semiclassical 3D Neumann Laplacian with variable magnetic field
    Raymond, Nicolas
    ASYMPTOTIC ANALYSIS, 2010, 68 (1-2) : 1 - 40
  • [29] The regularized 3D Boussinesq equations with fractional Laplacian and no diffusion
    Bessaih, H.
    Ferrario, B.
    JOURNAL OF DIFFERENTIAL EQUATIONS, 2017, 262 (03) : 1822 - 1849
  • [30] Dimensionality Reduction of Laplacian Embedding for 3D Mesh Reconstruction
    Mardhiyah, I.
    Madenda, S.
    Salim, R. A.
    Wiryana, I. M.
    2016 INTERNATIONAL CONGRESS ON THEORETICAL AND APPLIED MATHEMATICS, PHYSICS AND CHEMISTRY, 2016, 725