Stability and efficiency performance of pumped hydro energy storage system for higher flexibility

被引:29
|
作者
Zhao, Ziwen [1 ,2 ]
Yuan, Yichen [1 ,2 ]
He, Mengjiao [1 ,2 ]
Jurasz, Jakub [3 ]
Wang, Jianan [1 ,2 ]
Egusquiza, Monica [4 ]
Egusquiza, Eduard [4 ]
Xu, Beibei [1 ,2 ]
Chen, Diyi [1 ,2 ]
机构
[1] Northwest A&F Univ, Key Lab Agr Soil & Water Engn Arid & Semiarid Area, Minist Educ, Yangling 712100, Shaanxi, Peoples R China
[2] Northwest A&F Univ, Inst Water Resources & Hydropower Res, Yangling 712100, Shaanxi, Peoples R China
[3] Wroclaw Univ Sci & Technol, Wroclaw, Poland
[4] Polytech Univ Catalonia UPC, Ctr Ind Diagnost CDIF, Barcelona, Spain
关键词
Pumped hydro energy storage system; Flexible operation; Stability; Energy loss; Pump; -turbine; E fd field voltage; FLOW PUMP; TURBINE; SIMULATION; DESIGN;
D O I
10.1016/j.renene.2022.09.085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The pumped hydro energy storage station flexibility is perceived as a promising way for integrating more intermittent wind and solar energy into the power grid. However, this flexible operation mode challenges the stable and highly-efficient operation of the pump-turbine units. Therefore, this paper focuses on stability and efficiency performance of pumped hydro energy storage system (PHESS) under the various flexibility scenarios. First, a nonlinear model of PHESS coupling the hydraulic loss, mechanical loss and electrical loss of pumpturbine is established to study its stability and efficiency characteristics. Second, six flexibility scenarios including four transient processes and two steady processes are extracted based on the historical power output of a pump-turbine unit. Parameter responses indicate that the stability performance of PHESS got worse when the range of load-variation increased. Parameters response in the first 10s is steeper than that in the later 30s. Rotation speed and water head in part-load fluctuates periodically in a range of from -0.0024 to 0.01. In other words, 10 times more compared to the range response under the rated-load. Efficiency analysis suggests that the friction loss in scroll case is the dominated loss type in the transient processes, except for the FL condition. The responses of friction loss in straight pipe, impact loss in scroll case and volume loss are characterized by the corresponding discharge laws. The response curve of winding loss is similar with the response feature of rotation speed. This paper provides the stability and efficiency perspective when the operator exploits the flexibility potential of pumped hydro energy storage station.
引用
收藏
页码:1482 / 1494
页数:13
相关论文
共 50 条
  • [41] Motor Pump Group Efficiency in a Wind Energy Pumped Storage System
    Forcos, A.
    Marinescu, C.
    2011 7TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2011,
  • [42] Optimal Coordination of Wind Power and Pumped Hydro Energy Storage
    Al-Masri, Hussein M. K.
    Al-Quraan, Ayman
    AbuElrub, Ahmad
    Ehsani, Mehrdad
    ENERGIES, 2019, 12 (22)
  • [43] Ensuring sustainability in Libya with renewable energy and pumped hydro storage
    Elmnifi, Monaem
    Khaleel, Mohamed
    Vambol, Sergij
    Yeremenko, Sergiy
    Nassar, Yasser F.
    Dzhulai, Oleksandr
    ECOLOGICAL QUESTIONS, 2024, 35 (03)
  • [44] Unit Commitment with Wind Power and Pumped Hydro Energy Storage
    Niu, Qun
    Hua, Dandan
    Zhang, Letian
    Wang, Chao
    THEORY, METHODOLOGY, TOOLS AND APPLICATIONS FOR MODELING AND SIMULATION OF COMPLEX SYSTEMS, PT III, 2016, 645 : 273 - 281
  • [45] Life cycle sustainability assessment of pumped hydro energy storage
    Guo, Zhi
    Ge, Shuaishuai
    Yao, Xilong
    Li, Hui
    Li, Xiaoyu
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (01) : 192 - 204
  • [46] Pumped hydro energy storage to support 100% renewable electricity
    Blakers, Andrew
    Lu, Bin
    Stocks, Matt
    Anderson, Kirsten
    Nadolny, Anna
    2018 IEEE 7TH WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION (WCPEC) (A JOINT CONFERENCE OF 45TH IEEE PVSC, 28TH PVSEC & 34TH EU PVSEC), 2018, : 3672 - 3675
  • [47] Research on Pumped Storage Capacity Allocation of Cascade Hydro-Wind-Solar-Pumped Storage Hybrid System Considering Economy and Operational Stability
    Zhou, Yong
    Xia, Jinlei
    Wang, Lingling
    Jiang, Chuanwen
    2023 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA, I&CPS ASIA, 2023, : 601 - 607
  • [48] A Comparison of the Dynamic Performance of Conventional and Ternary Pumped Storage Hydro
    Nag, Soumyadeep
    Lee, Kwang Y.
    Suchitra, D.
    ENERGIES, 2019, 12 (18)
  • [49] Coordinated operation of pumped hydro energy storage with reversible pump turbine and co-located battery energy storage system
    Tadayon, Leon
    Meiers, Josef
    Ibing, Lukas
    Erdelkamp, Kevin
    Frey, Georg
    AT-AUTOMATISIERUNGSTECHNIK, 2025, 73 (02) : 136 - 144
  • [50] Flexibility Enhancements in Pumped Hydro Storage Power Plants through Variable Speed Drives
    Bontemps, Philippe
    Hugo, Nicolas
    Dujic, Drazen
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 1820 - 1825