Stability and efficiency performance of pumped hydro energy storage system for higher flexibility

被引:29
|
作者
Zhao, Ziwen [1 ,2 ]
Yuan, Yichen [1 ,2 ]
He, Mengjiao [1 ,2 ]
Jurasz, Jakub [3 ]
Wang, Jianan [1 ,2 ]
Egusquiza, Monica [4 ]
Egusquiza, Eduard [4 ]
Xu, Beibei [1 ,2 ]
Chen, Diyi [1 ,2 ]
机构
[1] Northwest A&F Univ, Key Lab Agr Soil & Water Engn Arid & Semiarid Area, Minist Educ, Yangling 712100, Shaanxi, Peoples R China
[2] Northwest A&F Univ, Inst Water Resources & Hydropower Res, Yangling 712100, Shaanxi, Peoples R China
[3] Wroclaw Univ Sci & Technol, Wroclaw, Poland
[4] Polytech Univ Catalonia UPC, Ctr Ind Diagnost CDIF, Barcelona, Spain
关键词
Pumped hydro energy storage system; Flexible operation; Stability; Energy loss; Pump; -turbine; E fd field voltage; FLOW PUMP; TURBINE; SIMULATION; DESIGN;
D O I
10.1016/j.renene.2022.09.085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The pumped hydro energy storage station flexibility is perceived as a promising way for integrating more intermittent wind and solar energy into the power grid. However, this flexible operation mode challenges the stable and highly-efficient operation of the pump-turbine units. Therefore, this paper focuses on stability and efficiency performance of pumped hydro energy storage system (PHESS) under the various flexibility scenarios. First, a nonlinear model of PHESS coupling the hydraulic loss, mechanical loss and electrical loss of pumpturbine is established to study its stability and efficiency characteristics. Second, six flexibility scenarios including four transient processes and two steady processes are extracted based on the historical power output of a pump-turbine unit. Parameter responses indicate that the stability performance of PHESS got worse when the range of load-variation increased. Parameters response in the first 10s is steeper than that in the later 30s. Rotation speed and water head in part-load fluctuates periodically in a range of from -0.0024 to 0.01. In other words, 10 times more compared to the range response under the rated-load. Efficiency analysis suggests that the friction loss in scroll case is the dominated loss type in the transient processes, except for the FL condition. The responses of friction loss in straight pipe, impact loss in scroll case and volume loss are characterized by the corresponding discharge laws. The response curve of winding loss is similar with the response feature of rotation speed. This paper provides the stability and efficiency perspective when the operator exploits the flexibility potential of pumped hydro energy storage station.
引用
收藏
页码:1482 / 1494
页数:13
相关论文
共 50 条
  • [31] Hybrid pumped hydro and battery storage for renewable energy based power supply system
    Javed, Muhammad Shahzad
    Zhong, Dan
    Ma, Tao
    Song, Aotian
    Ahmed, Salman
    APPLIED ENERGY, 2020, 257 (257)
  • [32] Parameter impact and sensitivity analysis of a pumped hydro compressed air energy storage system
    Yang, Biao
    Li, Deyou
    Fu, Xiaolong
    Wang, Hongjie
    Gong, Ruzhi
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [33] Thermodynamic and exergy analysis of a combined pumped hydro and compressed air energy storage system
    Mozayeni, Hamidreza
    Wang, Xiaolin
    Negnevitsky, Michael
    SUSTAINABLE CITIES AND SOCIETY, 2019, 48
  • [34] Geographic information system algorithms to locate prospective sites for pumped hydro energy storage
    Lu, Bin
    Stocks, Matthew
    Blakers, Andrew
    Anderson, Kirsten
    APPLIED ENERGY, 2018, 222 : 300 - 312
  • [35] A New Energy Storage System Coupled with Compressed Air and Pumped-Hydro Energy Storage and Related Thermodynamic Analysis
    Li C.
    He X.
    Tao F.
    Wang H.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2022, 56 (04): : 40 - 49and71
  • [36] Load Frequency Control of Microgrid System by Battery and Pumped-Hydro Energy Storage
    Coban, Hasan Huseyin
    Rehman, Aysha
    Mousa, Mohamed
    WATER, 2022, 14 (11)
  • [37] DISPATCH OF PUMPED HYDRO STORAGE ON AN INTERCONNECTED HYDROTHERMAL SYSTEM
    KENNEDY, T
    MABUCE, EM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (06): : 446 - &
  • [38] 100% renewable energy with pumped-hydro-energy storage in Nepal
    Lohani, Sunil Prasad
    Blakers, Andrew
    CLEAN ENERGY, 2021, 5 (02): : 243 - 253
  • [39] Improving the Control System for Pumped Storage Hydro Plant
    Mansoor, Sa'ad P.
    COMPUTER COMMUNICATION AND MANAGEMENT, 2011, 5 : 669 - 674
  • [40] Comprehensive assessment and analysis of cavitation scale effects on energy conversion and stability in pumped hydro energy storage units
    Zhao, Haoru
    Zhu, Baoshan
    Jiang, Boshuang
    ENERGY CONVERSION AND MANAGEMENT, 2025, 325