Readout-segmented Echo-pIanar Imaging Improves the Diagnostic Performance of Diffusion-weighted MR Breast Examinations at 3.0 T

被引:169
|
作者
Bogner, Wolfgang [1 ]
Pinker-Domenig, Katja [2 ]
Bickel, Hubert [2 ]
Chmelik, Marek [1 ]
Weber, Michael
Helbich, Thomas H. [2 ]
Trattnig, Siegfried [1 ]
Gruber, Stephan [1 ]
机构
[1] Med Univ Vienna, Dept Radiol, MR Ctr Excellence, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Radiol, Div Mol & Gender Imaging, A-1090 Vienna, Austria
关键词
NEOADJUVANT CHEMOTHERAPY; DIFFERENTIAL-DIAGNOSIS; HIGH-RISK; ADC MAP; CANCER; LESIONS; COEFFICIENT; BENIGN; EPI; MAMMOGRAPHY;
D O I
10.1148/radiol.12111494
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To qualitatively and quantitatively compare the diagnostic value of diffusion-weighted (DW) magnetic resonance (MR) imaging based on standard single-shot echo-planar imaging and readout-segmented echo-planar imaging in patients with breast cancer at 3.0 T. Materials and Methods: Institutional review board approval and written informed consent were obtained. Forty-seven patients with 49 histopathologically verified lesions were included in this study. In all patients, DW imaging, with single-shot echo-planar imaging and readout-segmented echo-planar imaging with comparable imaging parameters, was performed with a 3.0-T MR imager. Two independent readers visually assessed image quality and lesion conspicuity, and image properties (ie, signal-to-noise ratio, contrast, geometric distortions) were quantified. Regions of interest were drawn in all lesions (28 malignant, 21 benign) and in the normal breast parenchyma to investigate differences in apparent diffusion coefficient (ADC). Diagnostic accuracy was calculated on the basis of an ADC threshold of 1.25 x 10(-3) mm(2)/sec. Results: Each reader found a higher diagnostic accuracy for readout-segmented (96%) than for single-shot (90%) echo-planar imaging. The area under the curve for readout-segmented echo-planar imaging (0.981) was significantly larger than for single-shot echo-planar imaging (0.867) (P = .026). There was no significant difference in the ADC obtained by using either DW imaging method. Lesion conspicuity and image quality of readout-segmented echo-planar imaging were rated superior to those of single-shot echo-planar imaging (P < .001). Readout-segmented echo-planar imaging reduced geometric distortions by a factor of three. Conclusion: DW imaging based on readout-segmented echo-planar imaging provided significantly higher image quality and lesion conspicuity than single-shot echo-planar imaging by reducing geometric distortions, image blurring, and artifact level with a clinical high-field-strength MR imager. Thereby, readout-segmented echo-planar imaging reached a higher diagnostic accuracy for the differentiation of benign and malignant breast lesions. (C) RSNA, 2012
引用
收藏
页码:64 / 76
页数:13
相关论文
共 50 条
  • [41] Application value of simultaneous multislice readout-segmented echo-planar imaging for diffusion-weighted MRI in differentiation of rectal cancer grade
    Zhou, Mi
    Huang, Hongyun
    Li, Hang
    Yan, Guihua
    Tang, Baijie
    Chen, Meining
    Wang, Yuting
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (04) : 621 - 629
  • [42] Editorial for "Intraobserver and Interobserver Reproducibility of Breast Diffusion-Weighted Imaging Quantitative Parameters: Readout-Segmented vs. Single-Shot Echo-Planar Imaging"
    Loubrie, Stephane
    Batasin, Summer
    Rakow-Penner, Rebecca
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (06) : 1737 - 1738
  • [43] Application value of simultaneous multislice readout-segmented echo-planar imaging for diffusion-weighted MRI in differentiation of rectal cancer grade
    Mi Zhou
    Hongyun Huang
    Hang Li
    Guihua Yan
    Baijie Tang
    Meining Chen
    Yuting Wang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 621 - 629
  • [44] Are ADC values of readout-segmented echo-planar diffusion-weighted imaging (RESOLVE) correlated with pathological prognostic factors in rectal adenocarcinoma?
    Cui Tang
    Mou-bin Lin
    Jin-lei Xu
    Lan-hua Zhang
    Xiao-ming Zuo
    Zhong-shuai Zhang
    Meng-xiao Liu
    Jin-ming Xu
    World Journal of Surgical Oncology, 16
  • [45] Comparison of Readout-Segmented and Conventional Single-Shot for Echo-Planar Diffusion-Weighted Imaging in the Assessment of Kidney Interstitial Fibrosis
    Friedli, Iris
    Crowe, Lindsey Alexandra
    de Perrot, Thomas
    Berchtold, Lena
    Martin, Pierre-Yves
    de Seigneux, Sophie
    Vallee, Jean-Paul
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1631 - 1640
  • [46] Are ADC values of readout-segmented echo-planar diffusion-weighted imaging (RESOLVE) correlated with pathological prognostic factors in rectal adenocarcinoma?
    Tang, Cui
    Lin, Mou-bin
    Xu, Jin-lei
    Zhang, Lan-hua
    Zuo, Xiao-ming
    Zhang, Zhong-shuai
    Liu, Meng-xiao
    Xu, Jin-ming
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2018, 16
  • [47] Comparison of computed versus acquired readout-segmented diffusion-weighted imaging in visualizing scrotal or testicular lesions
    Yao, F.
    Li, J.
    Huang, M.
    Gao, X.
    Zhang, Y.
    CLINICAL RADIOLOGY, 2024, 79 (11) : 818 - 825
  • [48] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [49] Diffusion-Weighted MRI to Assess Sacroiliitis: Improved Image Quality and Diagnostic Performance of Readout-Segmented Echo-Planar Imaging (EPI) Over Conventional Single-Shot EPI
    Zhang, Hua
    Huang, Hongjie
    Zhang, Yuyang
    Tu, Zhanhai
    Xiao, Zebin
    Chen, Junmin
    Cao, Dairong
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (02) : 450 - 458
  • [50] Comparison of Readout-Segmented Echo-Planar Imaging (EPI) and Single-Shot EPI in Clinical Application of Diffusion-Weighted Imaging of the Pediatric Brain
    Yeom, Kristen W.
    Holdsworth, Samantha J.
    Van, Anh T.
    Iv, Michael
    Skare, Stefan
    Lober, Robert M.
    Bammer, Roland
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : W437 - W443