Accuracy of 9 intraoral scanners for complete-arch image acquisition: A qualitative and quantitative evaluation

被引:108
|
作者
Kim, Ryan Jin-Young [1 ]
Park, Ji-Man [2 ]
Shim, June-Sung [2 ]
机构
[1] Seoul Natl Univ, Dent Res Inst, Sch Dent, Seoul, South Korea
[2] Yonsei Univ, Dept Prosthodont, Coll Dent, 50-1 Yonsei Ro, Seoul, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2018年 / 120卷 / 06期
关键词
IN-VIVO PRECISION; CAD/CAM TECHNOLOGY; DIGITAL METHODS; CONVENTIONAL IMPRESSIONS; CROWNS; TRUENESS; FIT;
D O I
10.1016/j.prosdent.2018.01.035
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Different intraoral scanners (IOSs) are available for digital dentistry. However, information on the accuracy of various IOSs for complete-arch digital scans is limited. Purpose. The purpose of this in vitro study was to evaluate the trueness and precision of complete-arch digital scans produced by 9 IOSs, using the superimposition method, and to compare them based on characteristics including the data capture principle and mode and the need for powder coating. Material and methods. Nine IOSs were used to obtain standard tessellation language (STL) data for a bimaxillary complete-arch model with various cavity preparations (N=10). The scanning performance was evaluated quantitatively and qualitatively. For quantitative evaluation, the images were processed and analyzed using 3-dimensional (3D) analysis software. After we superimposed the datasets, trueness was obtained by comparing it with the reference scan, and precision was obtained from intragroup comparisons. The IOSs were compared based on the data capture principle and mode and the need for powder coating. Statistical analyses were conducted using a Kruskal-Wallis test, followed by multiple Mann-Whitney U tests for pairwise comparisons among groups (alpha=.05). For qualitative evaluation, surface smoothness and sharp edge reproducibility of the digital images were compared. Results. The median precision values were lowest in the TRIOS model (average, 34.70 mu m; maximum, 263.55 mu m) and highest in the E4D model (average, 357.05 mu m; maximum 2309.45 mu m). Median average trueness values were lowest in the TRIOS model (42.30 mu m) and highest in the Zfx IntraScan model (153.80 mu m). The CS 3500 model had the lowest median maximum trueness values (450.75 mu m); the E4D model had the highest values (2680.55 mu m). Individual image and video sequence data captures showed similar median average trueness values (P>.05); the median maximum values of individual images were higher than those of the video sequence (P<.05). Swept source optical coherence tomography (SS-OCT) exhibited higher trueness values than those of other scanning principles (P<.05). The FastScan and True Definition, which require powder coating, showed significantly better trueness than other IOSs that did not require powdering (P<.05). The E4D, PlanScan, and Zfx IntraScan models had an increased tendency to produce images with imperfect surface features and to round off sharp edges. Conclusions. The E4D and Zfx IntraScan models did not perform as accurately as the other IOSs. The data capture principle of SS-OCT and the mode of individual image acquisition exhibited inferior trueness. The FastScan and True Definition, which require powder coating, exhibited better trueness. The qualitative aspects of the IOSs varied in terms of polygon shapes, sharp edge reproducibility, and surface smoothness.
引用
收藏
页码:895 / +
页数:10
相关论文
共 50 条
  • [31] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180
  • [32] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694
  • [33] Accuracy of full-arch scans using intraoral scanners
    Sebastian B. M. Patzelt
    Archontia Emmanouilidi
    Susanne Stampf
    Joerg R. Strub
    Wael Att
    [J]. Clinical Oral Investigations, 2014, 18 : 1687 - 1694
  • [34] Effect of different arch widths on the accuracy of three intraoral scanners
    Kaewbuasa, Narin
    Ongthiemsak, Chakree
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (04): : 205 - 215
  • [35] Effect of scan pattern on complete-arch scans with 4 digital scanners
    Latham, Jason
    Ludlow, Mark
    Mennito, Anthony
    Kelly, Abigail
    Evans, Zachary
    Renne, Walter
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 85 - 95
  • [36] Effect of scan powder and scanning technology on measured deviations of complete-arch implant supported frameworks digitized with industrial and intraoral scanners
    Donmez, Mustafa Borga
    Cakmak, Gulce
    Dede, Dogu Omur
    Kucukekenci, Ahmet Serkan
    Lu, Wei-En
    Schumacher, Fernanda Lang
    Revilla-Leon, Marta
    Yilmaz, Burak
    [J]. JOURNAL OF DENTISTRY, 2023, 138
  • [37] Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods
    Mai, Hai Yen
    Mai, Hang-Nga
    Lee, Cheong-Hee
    Lee, Kyu-Bok
    Kim, So-yeun
    Lee, Jae-Mok
    Lee, Keun-Woo
    Lee, Du-Hyeong
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (02): : 88 - 95
  • [38] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117
  • [39] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Bowen Ma
    Xinxin Yue
    Yujie Sun
    Lingyan Peng
    Wei Geng
    [J]. BMC Oral Health, 21
  • [40] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    [J]. BMC ORAL HEALTH, 2021, 21 (01)