In vitro and in vivo comparison of three different intravascular ultrasound catheter designs

被引:11
|
作者
Fort, S
Freeman, NA
Johnston, P
Cohen, EA
Foster, FS
机构
[1] Univ Toronto, Hlth Sci Ctr, Schulich Heart Ctr, Sunnybrook & Womens Coll, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Biophys, Toronto, ON M4N 3M5, Canada
关键词
intravascular ultrasound; high frequency;
D O I
10.1002/ccd.1087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) is an invasive imaging modality which provides detailed two-dimensional images of blood vessels. There are currently two different types of IVUS catheters available, namely, the phased-array and the mechanical designs. The operating ultrasound frequency of these catheters ranges from 20 to 40 MHz. This study sought to evaluate the image quality, accuracy of diameter and pullback length measurements, and catheter handling characteristics of three different IVUS catheters currently available for clinical use using both in vitro phantom models and in patients undergoing percutaneous coronary intervention (PCI). in gelatin phantom models, image quality assessed on a semiquantitative scale was significantly different between the three IVUS catheters (P = 0.01) with the 40-MHz catheter providing the best images. Accuracy of lumen diameter measurements, when compared to optical microscopy, were similar between the three IVUS catheter designs (all R-2 = 0.99). There were no significant differences in accuracy of pullback length measurements in vitro between the three designs. However, there were differences in the performance of the three IVUS catheters when used for preinterventional imaging in patients undergoing PCI. Both mechanical IVUS catheters were associated with lower procedural, fluoroscopy, and lesion crossing times compared to the phased-array catheter (all P < 0.05). There were no significant differences between the catheters during postinterventional IVUS imaging. There were also small but potentially important differences with regards to clinical events and complications associated with the use of the different IVUS catheters during the PCI procedures, reflecting differences in catheter design. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:382 / 392
页数:11
相关论文
共 50 条
  • [1] Comparison of quantitative measurements between two different intravascular ultrasound systems: In vitro and in vivo studies
    Yamada, Ryotaro
    Okura, Hiroyuki
    Kume, Teruyoshi
    Hayashida, Akihiro
    Neishi, Yoji
    Kawamoto, Takahiro
    Yoshida, Kiyoshi
    JOURNAL OF CARDIOLOGY, 2013, 61 (3-4) : 201 - 205
  • [2] Intravascular ultrasound comparison of chronic recoil among different stent designs
    Hong, MK
    Park, SW
    Lee, CW
    Ko, JY
    Kang, DH
    Song, JK
    Kim, JJ
    Hoffmann, R
    Mintz, GS
    Park, SJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (10): : 1247 - +
  • [3] Local Intravascular Drug Delivery: In Vitro Comparison of Three Catheter Systems
    Heiko Alfke
    Hans-Joachim Wagner
    Christian Calmer
    Klaus Jochen Klose
    CardioVascular and Interventional Radiology, 1998, 21 : 50 - 56
  • [4] Local intravascular drug delivery: In vitro comparison of three catheter systems
    Alfke, H
    Wagner, HJ
    Calmer, C
    Klose, KJ
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (01) : 50 - 56
  • [5] Rotational Intravascular Multidirectional Ultrasound Catheter for Sonothrombolysis of Retracted Clots: An in Vitro and in Vivo Study
    Wu, Huaiyu
    Kim, Jinwook
    Zhang, Bohua
    Owens, Gabe
    Stocker, Greyson
    Chen, Mengyue
    Kreager, Benjamin C.
    Cornett, Ashley
    Bautista, Kathlyne
    Kaovasia, Tarana
    Dayton, Paul A.
    Xu, Zhen
    Jiang, Xiaoning
    ENGINEERING, 2024, 42 : 235 - 243
  • [6] Comparison of quantitative measurements between two different intravascular ultrasound catheters and consoles: in vitro and in vivo studies
    Okura, Hiroyuki
    Watanabe, Makoto
    Miura, Akihiro
    Kurokawa, Muneo
    Ueda, Tomoya
    Soeda, Tsunenari
    Saito, Yoshihiko
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (01) : 109 - 115
  • [7] Comparison of quantitative measurements between two different intravascular ultrasound catheters and consoles: in vitro and in vivo studies
    Hiroyuki Okura
    Makoto Watanabe
    Akihiro Miura
    Muneo Kurokawa
    Tomoya Ueda
    Tsunenari Soeda
    Yoshihiko Saito
    Cardiovascular Intervention and Therapeutics, 2022, 37 : 109 - 115
  • [8] In vivo recoil evaluation of different designs of stents in coronary vessels: Analysis with intravascular ultrasound.
    Telayna, J
    Lev, G
    Valdivieso, L
    Menendez, M
    Mendiz, O
    de la Serna, F
    Wisner, J
    Londero, H
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (7A): : 45S - 45S
  • [9] In vivo intravascular imaging with OCT: Comparison with ultrasound
    Li, XD
    Gold, H
    Weissman, N
    Pitris, C
    Saunders, K
    Ghanti, R
    Fujimoto, J
    Brezinski, M
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 32 - 34
  • [10] Intravascular ultrasound imaging of atherosclerotic renal arteries: comparison between in vitro and in vivo studies
    Yasuda, G
    Takizawa, T
    Takasaki, I
    Shionoiri, H
    Umemura, S
    Shimoyama, K
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (07) : 1690 - 1695