Validation of Automated Perfusion-Weighted Phase-Resolved Functional Lung (PREFUL)-MRI in Patients With Pulmonary Diseases

被引:51
|
作者
Behrendt, Lea [1 ,2 ,3 ]
Voskrebenzev, Andreas [1 ,2 ,3 ]
Klimes, Filip [1 ,2 ,3 ]
Gutberlet, Marcel [1 ,2 ,3 ]
Winther, Hinrich B. [1 ]
Kaireit, Till F. [1 ,2 ,3 ]
Alsady, Tawfik Moher [1 ,2 ,3 ]
Poehler, Gesa H. [1 ,2 ,3 ]
Derlin, Thorsten [4 ]
Wacker, Frank [1 ,2 ,3 ]
Vogel-Claussen, Jens [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Dept Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Biomed Res Endstage & Obstruct Lung Dis BREATH, Hannover, Germany
[3] German Ctr Lung Res DZL, Hannover, Germany
[4] Hannover Med Sch, Dept Nucl Med, Hannover, Germany
关键词
PREFUL; Fourier decomposition; lung MRI; dynamic contrast enhanced MRI; perfusion; validation; BOLUS-TRACKING DATA; FOURIER DECOMPOSITION; GADOLINIUM DEPOSITION; MRI; DECONVOLUTION; VENTILATION; COPD;
D O I
10.1002/jmri.27027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Perfusion-weighted (Qw) noncontrast-enhanced proton lung MRI is a promising technique for assessment of pulmonary perfusion, but still requires validation. Purpose To improve perfusion-weighted phase-resolved functional lung (PREFUL)-MRI, to validate PREFUL with perfusion single photon emission computed tomography (SPECT) as a gold standard, and to compare PREFUL with dynamic contrast-enhanced (DCE)-MRI as a reference. Study Type: Retrospective. Population Twenty patients with chronic obstructive pulmonary disease (COPD), 14 patients with cystic fibrosis (CF), and 21 patients with chronic thromboembolic pulmonary hypertension (CTEPH) were included. Field Strength/Sequence For PREFUL-MRI, a spoiled gradient echo sequence and for DCE-MRI a 3D time-resolved angiography with stochastic trajectories sequence were used at 1.5T. Assessment PREFUL-MRI coronal slices were acquired in free-breathing. DCE-MRI was performed in breath-hold with injection of 0.03 mmol/kg bodyweight of gadoteric acid at a rate of 4 cc/s. Perfusion SPECT images were obtained for six CTEPH patients. Images were coregistered. An algorithm to define the appropriate PREFUL perfusion phase was developed using perfusion SPECT data. Perfusion defect percentages (QDP) and Qw-values were calculated for all methods. For PREFUL quantitative perfusion values (PREFULQ) and for DCE pulmonary blood flow (PBF) was calculated. Statistical Tests Obtained parameters were assessed using Pearson correlation and Bland-Altman analysis. Results Qw-SPECT correlated with Qw-DCE (r = 0.50, P < 0.01) and Qw-PREFUL (r = 0.47, P < 0.01). Spatial overlap of QDP maps showed an agreement >= 67.7% comparing SPECT and DCE, >= 64.1% for SPECT and PREFUL, and >= 60.2% comparing DCE and PREFUL. Significant correlations of Qw-PREFUL and Qw-DCE were found (COPD: r = 0.79, P < 0.01; CF: r = 0.77, P < 0.01; CTEPH: r = 0.73, P < 0.01). PREFULQ/PBF correlations were similar/lower (CF, CTEPH: P > 0.12; COPD: P < 0.01) compared to Qw-PREFUL/DCE correlations. PREFULQ-values were higher/similar compared to PBF-values (COPD, CF: P < 0.01; CTEPH: P = 0.026). Data Conclusion The automated PREFUL algorithm may allow for noncontrast-enhanced pulmonary perfusion assessment in COPD, CF, and CTEPH patients comparable to DCE-MRI. Level of Evidence 3 Technical Efficacy Stage 2
引用
收藏
页码:103 / 114
页数:12
相关论文
共 43 条
  • [41] Evaluation of image registration algorithms for 3D phase-resolved functional lung ventilation magnetic resonance imaging in healthy volunteers and chronic obstructive pulmonary disease patients
    Klimes, Filip
    Voskrebenzev, Andreas
    Gutberlet, Marcel
    Grimm, Robert
    Wacker, Frank
    Vogel-Claussen, Jens
    NMR IN BIOMEDICINE, 2023, 36 (03)
  • [42] Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients
    Bauman, Grzegorz
    Puderbach, Michael
    Heimann, Tobias
    Kopp-Schneider, Annette
    Fritzsching, Eva
    Mall, Marcus A.
    Eichinger, Monika
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2371 - 2377
  • [43] Alterations in Flow Patterns and Wall Shear Stress in Pulmonary Artery Visualized With Phase-resolved 3D Cine Phase Contrast MRI (4D-Flow) in Patients With Systemic Sclerosis
    Suwa, Kenichiro
    Sakakibara, Tomoaki
    Saitoh, Takeji
    Kaneko, Yutaro
    Sano, Makoto
    Saotome, Masao
    Urushida, Tsuyoshi
    Katoh, Hideki
    Satoh, Hiroshi
    Takehara, Yasuo
    Sakahara, Harumi
    Hayashi, Hideharu
    CIRCULATION, 2015, 132