Validation of Automated Perfusion-Weighted Phase-Resolved Functional Lung (PREFUL)-MRI in Patients With Pulmonary Diseases

被引:51
|
作者
Behrendt, Lea [1 ,2 ,3 ]
Voskrebenzev, Andreas [1 ,2 ,3 ]
Klimes, Filip [1 ,2 ,3 ]
Gutberlet, Marcel [1 ,2 ,3 ]
Winther, Hinrich B. [1 ]
Kaireit, Till F. [1 ,2 ,3 ]
Alsady, Tawfik Moher [1 ,2 ,3 ]
Poehler, Gesa H. [1 ,2 ,3 ]
Derlin, Thorsten [4 ]
Wacker, Frank [1 ,2 ,3 ]
Vogel-Claussen, Jens [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Dept Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Biomed Res Endstage & Obstruct Lung Dis BREATH, Hannover, Germany
[3] German Ctr Lung Res DZL, Hannover, Germany
[4] Hannover Med Sch, Dept Nucl Med, Hannover, Germany
关键词
PREFUL; Fourier decomposition; lung MRI; dynamic contrast enhanced MRI; perfusion; validation; BOLUS-TRACKING DATA; FOURIER DECOMPOSITION; GADOLINIUM DEPOSITION; MRI; DECONVOLUTION; VENTILATION; COPD;
D O I
10.1002/jmri.27027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Perfusion-weighted (Qw) noncontrast-enhanced proton lung MRI is a promising technique for assessment of pulmonary perfusion, but still requires validation. Purpose To improve perfusion-weighted phase-resolved functional lung (PREFUL)-MRI, to validate PREFUL with perfusion single photon emission computed tomography (SPECT) as a gold standard, and to compare PREFUL with dynamic contrast-enhanced (DCE)-MRI as a reference. Study Type: Retrospective. Population Twenty patients with chronic obstructive pulmonary disease (COPD), 14 patients with cystic fibrosis (CF), and 21 patients with chronic thromboembolic pulmonary hypertension (CTEPH) were included. Field Strength/Sequence For PREFUL-MRI, a spoiled gradient echo sequence and for DCE-MRI a 3D time-resolved angiography with stochastic trajectories sequence were used at 1.5T. Assessment PREFUL-MRI coronal slices were acquired in free-breathing. DCE-MRI was performed in breath-hold with injection of 0.03 mmol/kg bodyweight of gadoteric acid at a rate of 4 cc/s. Perfusion SPECT images were obtained for six CTEPH patients. Images were coregistered. An algorithm to define the appropriate PREFUL perfusion phase was developed using perfusion SPECT data. Perfusion defect percentages (QDP) and Qw-values were calculated for all methods. For PREFUL quantitative perfusion values (PREFULQ) and for DCE pulmonary blood flow (PBF) was calculated. Statistical Tests Obtained parameters were assessed using Pearson correlation and Bland-Altman analysis. Results Qw-SPECT correlated with Qw-DCE (r = 0.50, P < 0.01) and Qw-PREFUL (r = 0.47, P < 0.01). Spatial overlap of QDP maps showed an agreement >= 67.7% comparing SPECT and DCE, >= 64.1% for SPECT and PREFUL, and >= 60.2% comparing DCE and PREFUL. Significant correlations of Qw-PREFUL and Qw-DCE were found (COPD: r = 0.79, P < 0.01; CF: r = 0.77, P < 0.01; CTEPH: r = 0.73, P < 0.01). PREFULQ/PBF correlations were similar/lower (CF, CTEPH: P > 0.12; COPD: P < 0.01) compared to Qw-PREFUL/DCE correlations. PREFULQ-values were higher/similar compared to PBF-values (COPD, CF: P < 0.01; CTEPH: P = 0.026). Data Conclusion The automated PREFUL algorithm may allow for noncontrast-enhanced pulmonary perfusion assessment in COPD, CF, and CTEPH patients comparable to DCE-MRI. Level of Evidence 3 Technical Efficacy Stage 2
引用
收藏
页码:103 / 114
页数:12
相关论文
共 43 条
  • [31] Functional MRI using Fourier decomposition of lung signal: Reproducibility of ventilation- and perfusion-weighted imaging in healthy volunteers
    Lederlin, Mathieu
    Bauman, Grzegorz
    Eichinger, Monika
    Dinkel, Julien
    Brault, Mathilde
    Biederer, Juergen
    Puderbach, Michael
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (06) : 1015 - 1022
  • [32] 3D phase-resolved functional lung ventilation MR imaging in healthy volunteers and patients with chronic pulmonary disease
    Klimes, Filip
    Voskrebenzev, Andreas
    Gutberlet, Marcel
    Kern, Agilo Luitger
    Behrendt, Lea
    Grimm, Robert
    Suhling, Hendrik
    Crisosto, Cristian Gonzales
    Kaireit, Till Frederick
    Poehler, Gesa Helen
    Glandorf, Julian
    Wacker, Frank
    Vogel-Claussen, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (02) : 912 - 925
  • [33] Effect of CFTR modulator therapy with elexacaftor/tezacaftor/ivacaftor on pulmonary ventilation derived by 3D phase-resolved functional lung MRI in cystic fibrosis patients
    Klimes, Filip
    Voskrebenzev, Andreas
    Gutberlet, Marcel
    Speth, Milan
    Grimm, Robert
    Dohna, Martha
    Hansen, Gesine
    Wacker, Frank
    Renz, Diane Miriam
    Dittrich, Anna-Maria
    Vogel-Claussen, Jens
    EUROPEAN RADIOLOGY, 2024, 34 (01) : 80 - 89
  • [34] Effect of CFTR modulator therapy with elexacaftor/tezacaftor/ivacaftor on pulmonary ventilation derived by 3D phase-resolved functional lung MRI in cystic fibrosis patients
    Filip Klimeš
    Andreas Voskrebenzev
    Marcel Gutberlet
    Milan Speth
    Robert Grimm
    Martha Dohna
    Gesine Hansen
    Frank Wacker
    Diane Miriam Renz
    Anna-Maria Dittrich
    Jens Vogel-Claussen
    European Radiology, 2024, 34 : 80 - 89
  • [35] Editorial for "Multicenter Standardization of Phase Resolved Functional Lung MRI in Patients With Suspected Chronic Thromboembolic Pulmonary Hypertension"
    Ota, Hideki
    Higuchi, Satoshi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (06) : 1965 - 1966
  • [36] Editorial for "Flow Volume Loop and Regional Ventilation Assessment Using Phase Resolved Functional Lung (PREFUL) MRI: Comparison With 129Xenon Ventilation MRI and Lung Function Testing"
    Eddy, Rachel L.
    Rayment, Jonathan H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1106 - 1107
  • [37] Free-breathing 3D phase-resolved functional lung MRI vs breath-hold hyperpolarized 129Xe ventilation MRI in patients with chronic obstructive pulmonary disease and healthy volunteers
    Klimes, Filip
    Kern, Agilo Luitger
    Voskrebenzev, Andreas
    Gutberlet, Marcel
    Grimm, Robert
    Mueller, Robin Aaron
    Behrendt, Lea
    Kaireit, Till Frederik
    Glandorf, Julian
    Alsady, Tawfik Moher
    Wacker, Frank
    Hohlfeld, Jens M.
    Vogel-Claussen, Jens
    EUROPEAN RADIOLOGY, 2024, : 943 - 956
  • [38] Lung ventilation- and perfusion-weighted Fourier decomposition magnetic resonance imaging: In vivo validation with hyperpolarized 3He and dynamic contrast-enhanced MRI
    Bauman, Grzegorz
    Scholz, Alexander
    Rivoire, Julien
    Terekhov, Maxim
    Friedrich, Janet
    de Oliveira, Andre
    Semmler, Wolfhard
    Schreiber, Laura Maria
    Puderbach, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 229 - 237
  • [39] Fully Automated and Real-Time Volumetric Measurement of Infarct Core and Penumbra in Diffusion- and Perfusion-Weighted MRI of Patients with Hyper-Acute Stroke
    Lee, Hyunna
    Jung, Kyesam
    Kang, Dong-Wha
    Kim, Namkug
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 262 - 272
  • [40] Fully Automated and Real-Time Volumetric Measurement of Infarct Core and Penumbra in Diffusion- and Perfusion-Weighted MRI of Patients with Hyper-Acute Stroke
    Hyunna Lee
    Kyesam Jung
    Dong-Wha Kang
    Namkug Kim
    Journal of Digital Imaging, 2020, 33 : 262 - 272