Issues for calibration of thermal dissipation sensors for measuring matric suction

被引:0
|
作者
Sawangsuriya, A. [1 ]
Benson, C. H. [2 ]
Wang, X. [3 ]
机构
[1] Dept Highways, Bangkok, Thailand
[2] Univ Washington, Seattle, WA 98195 USA
[3] Univ Wisconsin, Madison, WI USA
关键词
CONDUCTIVITY SENSORS; HEAT DISSIPATION; HYSTERESIS;
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Thermal dissipation sensors (TDS) are used for continuous and long-term in situ measurement: of matric suction. This paper addresses some important issues regarding calibration of TDSs and parametric equations are explored. Different test methods used to obtain calibration parameters are evaluated and recommendations are also given. The dry soil method and vacuum saturation method are found to be appropriated to completely dry and saturate the TDS, respectively. The study suggests that a calibration can be done by measuring completely dry TDS, saturated TDS, and the air entry suction of the TDS if a generalized shape parameter or function exists. Finally, a new generalized calibration equation is proposed to improve the fitting to the calibration data. Good agreement was found with direct matric suction measurements in the low suction range (< 1 MPa). The TDS cannot be used to measure a suction < 10 kPa.
引用
收藏
页码:209 / +
页数:2
相关论文
共 50 条
  • [31] Calibration of Tactile Pressure Sensors for Measuring Stress in Soils
    Gao, Y.
    Wang, Y. H.
    GEOTECHNICAL TESTING JOURNAL, 2013, 36 (04): : 568 - 574
  • [32] Measuring central blood pressure in youth: calibration issues
    Pucci, Giacomo
    D'Abbondanza, Marco
    Schillaci, Giuseppe
    JOURNAL OF HYPERTENSION, 2016, 34 (10) : 2100 - 2102
  • [33] Measuring thermal conductivity and water suction for variably saturated bentonite
    Yoon, Seok
    Kim, Geon-Young
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (03) : 1041 - 1048
  • [34] Calibration issues with Shack-Hartman sensors for metrology applications
    Greivenkamp, JE
    Smith, DG
    Goodwin, E
    OPTICAL FABRICATION, TESTING, AND METROLOGY, 2004, 5252 : 372 - 380
  • [35] Calibration of displacement sensors with nanometer accuracy using a measuring laser
    Wetzels, SFCL
    Schellekens, PHJ
    4TH INTERNATIONAL IMEKO SYMPOSIUM ON LASER METROLOGY FOR PRECISION MEASUREMENT AND INSPECTION IN INDUSTRY, PROCEEDINGS, 1996, : 91 - 100
  • [36] Measuring central blood pressure in youth: calibration issues Reply
    Lurbe, Empar
    Redon, Josep
    JOURNAL OF HYPERTENSION, 2016, 34 (10) : 2102 - 2102
  • [37] Calibration of non-ideal thermal conductivity sensors
    Koemle, N. I.
    Macher, W.
    Kargl, G.
    Bentley, M. S.
    GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS, 2013, 2 (01) : 151 - 156
  • [38] THERMAL ANCHORING AND CALIBRATION OF LOW-TEMPERATURE SENSORS
    KOEPPE, W
    KERNTECHNIK, 1973, 15 (08) : 353 - 357
  • [39] Development of the thermophysical parameter tester for measuring the soil matrix suction and optimization of the calibration function
    Kang, Jianguo
    Yu, Ziwang
    Zhang, Yanjun
    Zhang, Tong
    Yao, Peiyi
    Ye, Xiaoqi
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2023, 211
  • [40] Optimum design and calibration of visual sensors measuring linearity of steel pipe
    Xue, Ting
    Yang, Xue-You
    Wu, Bin
    Ye, Sheng-Hua
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2003, 36 (03): : 285 - 288