Issues for calibration of thermal dissipation sensors for measuring matric suction

被引:0
|
作者
Sawangsuriya, A. [1 ]
Benson, C. H. [2 ]
Wang, X. [3 ]
机构
[1] Dept Highways, Bangkok, Thailand
[2] Univ Washington, Seattle, WA 98195 USA
[3] Univ Wisconsin, Madison, WI USA
关键词
CONDUCTIVITY SENSORS; HEAT DISSIPATION; HYSTERESIS;
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Thermal dissipation sensors (TDS) are used for continuous and long-term in situ measurement: of matric suction. This paper addresses some important issues regarding calibration of TDSs and parametric equations are explored. Different test methods used to obtain calibration parameters are evaluated and recommendations are also given. The dry soil method and vacuum saturation method are found to be appropriated to completely dry and saturate the TDS, respectively. The study suggests that a calibration can be done by measuring completely dry TDS, saturated TDS, and the air entry suction of the TDS if a generalized shape parameter or function exists. Finally, a new generalized calibration equation is proposed to improve the fitting to the calibration data. Good agreement was found with direct matric suction measurements in the low suction range (< 1 MPa). The TDS cannot be used to measure a suction < 10 kPa.
引用
收藏
页码:209 / +
页数:2
相关论文
共 50 条
  • [21] Calibration of filter paper for measuring total soil suction
    Pande, P. B.
    Khandeshwar, S. R.
    Bajad, S. P.
    Raut, S. P.
    SN APPLIED SCIENCES, 2019, 1 (07):
  • [22] CALIBRATION OF WATERMARK SOIL-MOISTURE SENSORS FOR SOIL MATRIC POTENTIAL AND TEMPERATURE
    SPAANS, EJA
    BAKER, JM
    PLANT AND SOIL, 1992, 143 (02) : 213 - 217
  • [23] Measuring the Soil Water-Retention Curve Under Positive and Negative Matric Suction Regimes
    Alsherif, Nahed
    Wayllace, Alexandra
    Lu, Ning
    GEOTECHNICAL TESTING JOURNAL, 2015, 38 (04): : 442 - 451
  • [24] Calibration approach and range of observed sap flow influences transpiration estimates from thermal dissipation sensors
    Dix, Mackenzie J.
    Aubrey, Doug P.
    AGRICULTURAL AND FOREST METEOROLOGY, 2021, 307
  • [25] Automatic measuring and calibration unit for electrochemical sensors
    Zosel, J
    Kaden, H
    Mitschke, F
    CHEMISCHE TECHNIK, 1997, 49 (03): : 117 - 124
  • [26] Calibration of RO-based temperature sensors for a toolset for measuring thermal behavior of FPGA devices
    Weber, Pawel
    Zagrabski, Maciej
    Wojciechowski, Bartosz
    Nikodem, Maciej
    Kepa, Krzysztof
    Berezowski, Krzysztof S.
    MICROELECTRONICS JOURNAL, 2014, 45 (12) : 1753 - 1763
  • [27] A laboratory evaluation of Watermark electrical resistance and Campbell Scientific 229 heat dissipation matric potential sensors
    Jovanovic, NZ
    Annandale, JG
    WATER SA, 1997, 23 (03) : 227 - 232
  • [28] Towards the development on new high capacity tensiometers capable of measuring soil matric suction beyond 3 MPa
    Mendes, Joao
    Najdi, Abdallah
    Encalada, David
    Prat, Pere C.
    Ledesma, Alberto
    CANADIAN GEOTECHNICAL JOURNAL, 2022, : 1539 - 1552
  • [29] Calibration of CCD sensors mounted on geodetic measuring systems
    Volgyesi, Lajos
    Toth, Gyula
    SURVEY REVIEW, 2021, 53 (377) : 136 - 145
  • [30] Measuring Sensors Calibration in Worm Gear Rolling Testers
    Pueo, Marcos
    Acero, Raquel
    Gracia, Angel
    Santolaria, Jorge
    SENSORS, 2020, 20 (11)