Array of potentiometric sensors for simultaneous analysis of urea and potassium

被引:30
|
作者
Correia, DPA [1 ]
Magalhaes, JMCS [1 ]
Machado, AASC [1 ]
机构
[1] Fac Ciencias Porto, Dept Chem, LAQUIPAI, P-4169007 Oporto, Portugal
关键词
urea biosensors; array of potentionietric sensors; PCR and PLS2 calibration models; redundant biosensors response; blood serum analysis;
D O I
10.1016/j.talanta.2005.04.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Urea biosensors based on urease immobilized by crosslinking with BSA and glutharaldehyde coupled to ammonium ion-selective electrodes were included in arrays together with potassium, sodium and ammonium PVC membrane ion-selective electrodes. Multivariate calibration models based on PCR and PLS2 were built and tested for the simultaneous determination of urea and potassium. The results show that it is possible to obtain PCR and PLS2 calibration models for simultaneous determination of these two species, based on a very small set of calibration samples (nine samples). Coupling of biosensors with ion-selective electrodes in arrays of sensors raises a few problems related to the limited stability of response and unidirectional cross-talk of the biosensors, and this matter was also subjected to investigation in this work. Up to three identical urea biosensors were included in the arrays, and the data analysis procedure allowed the assessment of the relative performance of the sensors. The results show that at least two urea biosensors should be included in the array to improve urea determination. The prediction errors of the concentration of urea and potassium in the blood serum samples analyzed with this array and a PLS2 calibration model, based on nine calibration samples, were lower than 10 and 5%, respectively. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:773 / 782
页数:10
相关论文
共 50 条
  • [41] POTENTIOMETRIC ENZYME SENSORS
    VANDERSCHOOT, BH
    BERGVELD, P
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (4-5): : 335 - 335
  • [42] POTENTIOMETRIC GLUCOSE SENSORS
    HONOLD, F
    CAMMANN, K
    HORMONE AND METABOLIC RESEARCH, 1988, 20 : 47 - 49
  • [43] SIMULTANEOUS POTENTIOMETRIC ANALYSIS OF BENZALKONIUM-CHLORHEXIDINE COMBINATIONS
    PINZAUTI, S
    LAPORTA, E
    PHARMACEUTICA ACTA HELVETIAE, 1981, 56 (06): : 155 - 157
  • [44] Potentiometric ion sensors
    Bobacka, Johan
    Ivaska, Ari
    Lewenstam, Andrzej
    CHEMICAL REVIEWS, 2008, 108 (02) : 329 - 351
  • [45] A CMOS Integrable DDCCII-Based Readout System For Portable Potentiometric Sensors Array
    Ferri, G.
    Stornelli, V.
    Di Carlo, C.
    De Marcellis, A.
    D'Amico, A.
    Di Natale, C.
    Martinelli, E.
    OLFACTION AND ELECTRONIC NOSE, PROCEEDINGS, 2009, 1137 : 310 - +
  • [46] Beer classification based on the array of solid-contact potentiometric sensors with thiacalixarene receptors
    E. E. Stoikova
    N. N. Dolgova
    A. A. Savel’ev
    A. V. Galukhin
    I. I. Stoikov
    I. S. Antipin
    G. A. Evtyugin
    Russian Chemical Bulletin, 2014, 63 : 223 - 231
  • [47] SIMULTANEOUS DETERMINATION OF LEAD AND TIN WITH POTENTIOMETRIC STRIPPING ANALYSIS
    GARAI, T
    HORVATH, G
    BARTALIS, L
    LOCATELLI, C
    FAGIOLI, F
    ANNALI DI CHIMICA, 1994, 84 (1-2) : 55 - 70
  • [48] Beer classification based on the array of solid-contact potentiometric sensors with thiacalixarene receptors
    Stoikova, E. E.
    Dolgova, N. N.
    Savel'ev, A. A.
    Galukhin, A. V.
    Stoikov, I. I.
    Antipin, I. S.
    Evtyugin, G. A.
    RUSSIAN CHEMICAL BULLETIN, 2014, 63 (01) : 223 - 231
  • [49] NEW ENZYME SENSORS FOR UREA AND CREATININE ANALYSIS
    CAMPANELLA, L
    MAZZEI, F
    SAMMARTINO, MP
    TOMASSETTI, M
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1990, 23 (02): : 195 - 202
  • [50] COMPARISON OF POTENTIOMETRIC ENZYME SENSORS FOR UREA AND PENICILLIN-G - DIFFERENTIAL THICK-FILM SENSORS VERSUS CLASSICAL ELECTRODES
    EPPELSHEIM, C
    AUBECK, R
    HAMPP, N
    JOURNAL OF MEMBRANE SCIENCE, 1995, 100 (02) : 131 - 137