Array of potentiometric sensors for simultaneous analysis of urea and potassium

被引:30
|
作者
Correia, DPA [1 ]
Magalhaes, JMCS [1 ]
Machado, AASC [1 ]
机构
[1] Fac Ciencias Porto, Dept Chem, LAQUIPAI, P-4169007 Oporto, Portugal
关键词
urea biosensors; array of potentionietric sensors; PCR and PLS2 calibration models; redundant biosensors response; blood serum analysis;
D O I
10.1016/j.talanta.2005.04.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Urea biosensors based on urease immobilized by crosslinking with BSA and glutharaldehyde coupled to ammonium ion-selective electrodes were included in arrays together with potassium, sodium and ammonium PVC membrane ion-selective electrodes. Multivariate calibration models based on PCR and PLS2 were built and tested for the simultaneous determination of urea and potassium. The results show that it is possible to obtain PCR and PLS2 calibration models for simultaneous determination of these two species, based on a very small set of calibration samples (nine samples). Coupling of biosensors with ion-selective electrodes in arrays of sensors raises a few problems related to the limited stability of response and unidirectional cross-talk of the biosensors, and this matter was also subjected to investigation in this work. Up to three identical urea biosensors were included in the arrays, and the data analysis procedure allowed the assessment of the relative performance of the sensors. The results show that at least two urea biosensors should be included in the array to improve urea determination. The prediction errors of the concentration of urea and potassium in the blood serum samples analyzed with this array and a PLS2 calibration model, based on nine calibration samples, were lower than 10 and 5%, respectively. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:773 / 782
页数:10
相关论文
共 50 条
  • [21] Analysis of carcinoembryonic antigen using potentiometric sensors
    Comnea-Stancu, Ionela Raluca
    Staden, Raluca-Ioana Stefan-Van
    Van Staden, Jacobus Frederick
    Stanciu-Gavan, Camelia
    UPB Scientific Bulletin, Series B: Chemistry and Materials Science, 2015, 77 (03): : 25 - 32
  • [22] ANALYSIS OF CARCINOEMBRYONIC ANTIGEN USING POTENTIOMETRIC SENSORS
    Comnea-Stancu, Ionela Raluca
    Stefan-Van Staden, Raluca-Ioana
    Van Staden, Jacobus Frederick
    Stanciu-Gavan, Camelia
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2015, 77 (03): : 25 - 32
  • [23] Potentiometric urea biosensors
    Ozbek, Oguz
    Berkel, Caglar
    Isildak, Omer
    Isildak, Ibrahim
    CLINICA CHIMICA ACTA, 2022, 524 : 154 - 163
  • [24] POTENTIOMETRIC SENSORS
    WOOLF, AA
    JOURNAL OF CHEMICAL EDUCATION, 1987, 64 (04) : 384 - 384
  • [25] An electronic tongue using potentiometric all-solid-state PVC-membrane sensors for the simultaneous quantification of ammonium and potassium ions in water
    Gallardo, J
    Alegret, S
    Muñoz, R
    De-Román, M
    Leija, L
    Hernández, PR
    del Valle, M
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (02) : 248 - 256
  • [26] An electronic tongue using potentiometric all-solid-state PVC-membrane sensors for the simultaneous quantification of ammonium and potassium ions in water
    J. Gallardo
    S. Alegret
    R. Muñoz
    M. De-Román
    L. Leija
    P. R. Hernández
    M. del Valle
    Analytical and Bioanalytical Chemistry, 2003, 377 : 248 - 256
  • [27] Design of solid state array for simultaneous potentiometric and impedance sensing in gas phase
    Polk, BJ
    Smith, JA
    DeWeerth, SP
    Zhou, ZP
    Janata, J
    Domansky, K
    ELECTROANALYSIS, 1999, 11 (10-11) : 707 - 711
  • [28] Simultaneous Quantification of Heavy Metals Using a Solid State Potentiometric Sensor Array
    Jesus Gismera, Ma
    Arias, Sandra
    Teresa Sevilla, Ma
    Procopio, Jesus R.
    ELECTROANALYSIS, 2009, 21 (08) : 979 - 987
  • [29] Analysis of Potential Applicability of the Potentiometric Urea Biosensor to Real Samples
    Flores, Rafaela O.
    Silva, Livia Maria da C.
    Melo, Ariana F.
    Salgado, Andrea M.
    ICHEAP-11: 11TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-4, 2013, 32 : 367 - 372
  • [30] Simultaneous use of urea and potassium nitrate for Arthrospira (Spirulina) platensis cultivation
    Vieira, Denise C. M.
    Matsudo, Marcelo C.
    Sato, Sunao
    Converti, Attilio
    de Carvalho, Joao C. M.
    BIOTECHNOLOGY JOURNAL, 2012, 7 (05) : 649 - 655