Effect of an overhead shield on gamma-ray skyshine

被引:1
|
作者
Stedry, MH
Shultis, JK
Faw, RE
机构
[1] Kansas State University, Department of Nuclear Engineering, Manhattan
关键词
D O I
10.13182/NSE96-A24190
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A hybrid Monte Carlo and integral line-beam method is used to determine the effect of a horizontal slab shield above a gamma-ray source on the resulting skyshine doses. A simplified Monte Carlo procedure is used to determine the energy and angular distribution of photons escaping the source shield into the atmosphere. The escaping photons are then treated as a bare, point, skyshine source, and the integral line-beam method is used to estimate the skyshine dose at various distances from the source. From results for arbitrarily collimated and shielded sources, the skyshine dose is found to depend primarily on the mean-free-path thickness of the shield and only very weakly on the shield material.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [21] ANALYSIS OF MAJOR GAMMA-RAY SOURCES IN A PWR PRIMARY SHIELD
    SAPYTA, JJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 557 - 558
  • [22] Applications of Monte Carlo codes to a study of gamma-ray buildup factors, skyshine and duct streaming
    Hirayama, H
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 99 - 104
  • [23] Evaluation of the Environmental Gamma-ray Dose Rate by Skyshine Analysis During the Maintenance of an Activated TFC in ITER
    S. Sato
    H. Takatsu
    K. Maki
    K. Yamada
    S. Mori
    H. Iida
    R. T. Santoro
    Journal of Fusion Energy, 1997, 16 : 211 - 218
  • [24] Evaluation of the environmental gamma-ray dose rate by skyshine analysis during the maintenance of an activated TFC in ITER
    Sato, S
    Takatsu, H
    Maki, K
    Yamada, K
    Mori, S
    Iida, H
    Santoro, RT
    JOURNAL OF FUSION ENERGY, 1997, 16 (03) : 211 - 218
  • [25] BISMUTH GERMANATE GAMMA-RAY SPECTROMETER WITH A PLASTIC ANTICOINCIDENCE SHIELD.
    Wagenaar, Douglas J.
    Roberson, N.R.
    Weller, H.R.
    Tilley, D.R.
    Nuclear instruments and methods in physics research, 1985, A234 (01): : 109 - 115
  • [26] A THEORETICAL-MODEL FOR GAMMA-RAY ATTENUATION AND DISTRIBUTION IN A LAMINATED SHIELD
    RAHMAN, FA
    ELKALLA, EH
    AHMED, EE
    APPLIED RADIATION AND ISOTOPES, 1989, 40 (09) : 783 - 787
  • [27] A BISMUTH-GERMANATE GAMMA-RAY SPECTROMETER WITH A PLASTIC ANTICOINCIDENCE SHIELD
    WAGENAAR, DJ
    ROBERSON, NR
    WELLER, HR
    TILLEY, DR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 234 (01): : 109 - 115
  • [28] EVALUATION OF A NEUTRON SHIELD FOR ACTIVELY SHIELDED GAMMA-RAY TELESCOPES.
    Owens, Alan
    Myers, Richard M.
    Thompson, Michael G.
    Nuclear instruments and methods in physics research, 1986, 245 (2-3): : 569 - 570
  • [29] NEUTRON-FLUX AND GAMMA-RAY DOSE DISTRIBUTIONS IN NPR SHIELD
    GREENBORG, J
    NUCLEAR APPLICATIONS, 1966, 2 (05): : 430 - +
  • [30] Design of the radiation shield and collimator for neutron and gamma-ray diagnostics at EAST
    Chen, Weikun
    Hu, Liqun
    Zhong, Guoqiang
    Hong, Bing
    Zhou, Ruijie
    Li, Kai
    Huang, Liangsheng
    Cao, Hongrui
    FUSION ENGINEERING AND DESIGN, 2021, 172