Design of the radiation shield and collimator for neutron and gamma-ray diagnostics at EAST

被引:4
|
作者
Chen, Weikun [1 ,2 ]
Hu, Liqun [1 ]
Zhong, Guoqiang [1 ]
Hong, Bing [1 ]
Zhou, Ruijie [1 ]
Li, Kai [1 ]
Huang, Liangsheng [1 ,2 ]
Cao, Hongrui [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Peoples R China
基金
中国国家自然科学基金;
关键词
Fusion neutron; Gamma-ray; Collimator; Radiation shield; Tokamak;
D O I
10.1016/j.fusengdes.2021.112775
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
New compact radiation shields have been designed to reduce the scattered neutrons and background gamma-rays for neutron and gamma-ray diagnostics in the EAST hall. The design focused on optimizing radiation shielding performance versus volume and weight to fit the small amount of available space outside the tokamak device. Based on the Monte Carlo method and using the Geant4 tool kit, three-dimensional models of the shield were created for material selection and structural design optimization. The 10-cm and 15-cm polyethylene doped with 12 wt.% B4C, and 10-cm cast lead were finally selected for the main body of the shield. In addition, the shape and structure of the collimator in the front half of the shield are optimized, and a replaceable aperture adjuster module design has been adopted for the collimator. For incident particles with different energies, the collimation efficiency of the collimator has also been calculated.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Design status of the neutron and gamma-ray diagnostics for the Divertor Tokamak Test facility
    Marocco, D.
    Angelone, M.
    Belli, F.
    Caruggi, F.
    Croci, G.
    Esposito, B.
    Gandolfo, G.
    Gorini, G.
    Grosso, G.
    Nocente, M.
    Panza, F.
    Pillon, M.
    Pompili, F.
    Rigamonti, D.
    Rocchi, G.
    Scionti, J.
    Tardocchi, M.
    FUSION ENGINEERING AND DESIGN, 2024, 202
  • [2] RADIOPHOTOLUMINESCENT GAMMA-RAY DOSIMETRY OF MIXED NEUTRON GAMMA-RAY RADIATION FIELDS
    AMATO, CG
    MALSKY, SJ
    RADIOLOGY, 1961, 76 (02) : 290 - 291
  • [3] EVALUATION OF A NEUTRON SHIELD FOR ACTIVELY SHIELDED GAMMA-RAY TELESCOPES
    OWENS, A
    MYERS, RM
    THOMPSON, MG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 245 (2-3): : 569 - 570
  • [4] Design of a Rotational Modulation Collimator Utilizing Asymmetric Masks for the Gamma-Ray/Neutron Dual Imaging Technique
    Kim, Hyun Suk
    Lee, Gyemin
    Ye, Sung-Joon
    Kim, Geehyun
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [5] LEAD ELECTROPLATED GAMMA-RAY COLLIMATOR
    TOSSWILL, CH
    BEUSCHER, CJ
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (08) : C355 - C355
  • [6] EVALUATION OF A NEUTRON SHIELD FOR ACTIVELY SHIELDED GAMMA-RAY TELESCOPES.
    Owens, Alan
    Myers, Richard M.
    Thompson, Michael G.
    Nuclear instruments and methods in physics research, 1986, 245 (2-3): : 569 - 570
  • [7] NEUTRON-FLUX AND GAMMA-RAY DOSE DISTRIBUTIONS IN NPR SHIELD
    GREENBORG, J
    NUCLEAR APPLICATIONS, 1966, 2 (05): : 430 - +
  • [8] The collimator shape design of segmented gamma-ray scanning for radioactive waste
    Hou Suxia
    Luo Jijun
    Li Rusong
    Wang Yongcang
    ANNALS OF NUCLEAR ENERGY, 2020, 135
  • [9] Collimator design for gamma-ray cascade angular correlations in medical imaging
    Olshanoski, K.
    Nkuba, L.
    Dang, N. P.
    Fukuchi, T.
    Kanda, H.
    Lugendo, I. J.
    Sai, K. Vijay
    Ranagacharyulu, C.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (05)
  • [10] Definition of the radiation fields for the JET gamma-ray spectrometer diagnostics
    Zoita, Vasile
    Soare, Sorin
    Craciunescu, Teddy
    Curuia, Marian
    Kiptily, Vasily
    Balshaw, Nick
    Blanchard, Patrick
    Croft, David
    Murari, Andrea
    Syme, Brian
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 1366 - 1370