X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)

被引:1
|
作者
Kim, Kwang Hyun [1 ]
机构
[1] Jungwon Univ, Dept Med Engn, Goesan Gun, Chungcheongbuk, South Korea
关键词
Dual-energy X-ray; DXA; K-edge filter; X-ray beam hardening; RADIOGRAPHY; TOMOGRAPHY;
D O I
10.1109/TNS.2010.2050335
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports a new X-ray beam geometry to acquire two separated polychromatic X-rays as well as two separated fan beams using parallel different filters built in a single collimator. This newly designed X-ray spectrum was generated by a single X-ray shot but had the effect of double X-ray exposure. The two separated filters were used side by side. The first filter for the low energy spectra was 0.5 mm thick erbium and the second filter for the high energy spectra was composed of two layers of a 0.8 mm of copper and 0.4mmof rhodium. This combination of filters showed excellent performance of X-ray beam hardening regardless of the bone thickness in the soft tissue under DXA conditions.
引用
收藏
页码:2155 / 2158
页数:4
相关论文
共 50 条
  • [31] ENHANCED PRECISION WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    MAZESS, R
    CHESNUT, CH
    MCCLUNG, M
    GENANT, H
    CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (01) : 14 - 17
  • [32] The use of dual-energy x-ray absorptiometry in animals
    Grier, SJ
    Turner, AS
    Alvis, MR
    INVESTIGATIVE RADIOLOGY, 1996, 31 (01) : 50 - 62
  • [33] Dual-energy X-ray absorptiometry and body composition
    Laskey, MA
    NUTRITION, 1996, 12 (01) : 45 - 51
  • [34] Dual-energy X-ray Absorptiometry Quality Matters
    Krueger, Diane
    Binkley, Neil
    Morgan, Sarah
    JOURNAL OF CLINICAL DENSITOMETRY, 2018, 21 (02) : 155 - 156
  • [35] CLINICAL REPRODUCIBILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    WILLIAMSRUSSO, P
    HEALEY, JH
    SZATROWSKI, TP
    SCHNEIDER, R
    PAGET, S
    ALES, K
    SCHWARTZBERG, P
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (02) : 250 - 257
  • [36] Quality in dual-energy X-ray absorptiometry scans
    Morgan, Sarah L.
    Prater, Ginnie L.
    BONE, 2017, 104 : 13 - 28
  • [37] Dual-energy X-ray absorptiometry and body composition
    Plank, LD
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2005, 8 (03): : 305 - 309
  • [38] CHANGES IN BONE MINERALIZATION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY (DXA) DURING INFANCY
    KOO, W
    WALTERS, J
    CARLSON, SE
    PEDIATRIC RESEARCH, 1995, 37 (04) : A64 - A64
  • [39] In vivo measurement of human body composition by dual-energy X-ray absorptiometry (DXA)
    Thomsen, TK
    Jensen, VJ
    Henriksen, MG
    EUROPEAN JOURNAL OF SURGERY, 1998, 164 (02) : 133 - 137
  • [40] Fundamentals and pitfalls of bone densitometry using dual-energy X-ray absorptiometry (DXA)
    Watts, NB
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 (11) : 847 - 854