Artifact reduction in truncated CT using Sinogram completion

被引:26
|
作者
Chityala, R [1 ]
Hoffmann, KR [1 ]
Rudin, S [1 ]
Bednarek, DR [1 ]
机构
[1] SUNY Buffalo, Dept Phys, Buffalo, NY 14214 USA
关键词
Sinogram completion; truncated reconstruction; Sinogram; extrapolation; artifact reduction; dose reduction; reduced FOV;
D O I
10.1117/12.595450
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Truncation of projection data in CT produces significant artifacts in the reconstruction process due to non-locality of the Radon transform. In this paper, we present a method for reducing these truncation artifacts by estimating features that lie outside the region of interest (ROI) and using these features to complete the truncated sinogram. Projection images of an object are obtained. A sinogram is obtained by stacking profile data from all projection angles. A simulated truncated sinogram is generated by setting pixel values outside an ROI to zero. The truncated sinogram is then transformed into a (radius, phase) image, with pixel values in what we term as the Polar representation (PR) image corresponding to the minimum value along sine curves given by x = r*cos(projection angle + phase). The PR image contains data for radii greater than the ROI radius. Pixel values outside the ROI in the completed sinogram are determined as follows. For each pixel in the PR image, a sine curve is generated in the completed sinogram image outside the ROI, having the same pixel value as that of the PR image for that radius and phase. Successive sine curves are laid and the values of each are summed. The intensity outside is then equalized to the intensity inside the ROL The completed sinogram is then reconstructed, to obtain completed reconstruction. The percentage error in the difference image between the full FOV reconstruction and the corresponding completed reconstruction and the extrapolated-average reconstruction are 1.1 % and 3.3 % respectively. This indicates that the completed reconstruction is closer to full FOV reconstruction. Thus, the sinogram completion can be used to improve reconstructions from truncated data.
引用
收藏
页码:2110 / 2117
页数:8
相关论文
共 50 条
  • [11] Metal artifact reduction in CT-based attenuation correction of PET data using the virtual sinogram concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    [J]. 3rd International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2009, 2009,
  • [12] Metal Artifact Reduction in CT Based on Adaptive Steering Filter and Nonlocal Sinogram Inpainting
    Li, Yinsheng
    Bao, Xudong
    Yin, Xindao
    Chen, Yang
    Luo, Limin
    Chen, Wufan
    [J]. 2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 380 - 383
  • [13] Gaussian diffusion sinogram inpainting for X-ray CT metal artifact reduction
    Chengtao Peng
    Bensheng Qiu
    Ming Li
    Yihui Guan
    Cheng Zhang
    Zhongyi Wu
    Jian Zheng
    [J]. BioMedical Engineering OnLine, 16
  • [14] A metal artifact reduction scheme in CT by a Poisson fusion sinogram based postprocessing method
    Tang, Hui
    Lin, Yu Bing
    Sun, Guo Yan
    Bao, Xu Dong
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (02) : 245 - 257
  • [15] Metal Artifact Reduction in CT-Based Attenuation Correction of PET Data Using the Virtual Sinogram Concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1848 - +
  • [16] Metal artifact reduction algorithm using directional interpolation by sinogram decomposed derivatives
    Nam, Haewon
    Baek, Jongduk
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [17] Evaluation of Surrogate Data Quality in Sinogram-Based CT Metal-Artifact Reduction
    Oehler, May
    Kratz, Baerbel
    Knopp, Tobias
    Mueller, Jan
    Buzug, Thorsten M.
    [J]. IMAGE RECONSTRUCTION FROM INCOMPLETE DATA V, 2008, 7076
  • [18] CT Metal Artifact Reduction Method Based on Improved Image Segmentation and Sinogram In-Painting
    Chen, Yang
    Li, Yinsheng
    Guo, Hong
    Hu, Yining
    Luo, Limin
    Yin, Xindao
    Gu, Jianping
    Toumoulin, Christine
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2012, 2012
  • [19] Technical Note: A model-based sinogram correction for beam hardening artifact reduction in CT
    Lee, Sung Min
    Seo, Jin Keun
    Chung, Yong Eun
    Baek, Jongduk
    Park, Hyoung Suk
    [J]. MEDICAL PHYSICS, 2017, 44 (09) : E147 - E152
  • [20] Sparse-sampling CT Sinogram Completion using Generative Adversarial Networks
    Liu, Jiancong
    Li, Jiangwei
    [J]. 2020 13TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2020), 2020, : 640 - 644