Flattening filter free VMAT for a stereotactic, single-dose of 30 Gy to lung lesion in a 15-min treatment slot

被引:13
|
作者
Pokhrel, Damodar [1 ]
Sanford, Lana [1 ]
Dhanireddy, Bhaswanth [1 ]
Molloy, Janelle [1 ]
Randall, Marcus [1 ]
McGarry, Ronald C. [1 ]
机构
[1] Univ Kentucky, Med Phys Grad Program, Dept Radiat Med, Lexington, KY 40506 USA
来源
关键词
beam-on time; FFF-beam; outcomes; single dose; stereotactic lung treatment; VMAT; BODY RADIATION-THERAPY; MODULATED ARC THERAPY; FREE BEAMS; RADIOTHERAPY; CANCER; FRACTION; SBRT; REGIMENS; QUALITY; TUMORS;
D O I
10.1002/acm2.12829
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone-beam CT-guided single dose of lung stereotactic body radiotherapy (SBRT) treatment with a flattening filter free (FFF) beam and volumetric modulated arc therapy (VMAT) is a safe and highly effective treatment modality for selective small lung lesions. Four-dimensional (4D) CT-based treatment plans were generated using advanced AcurosXB algorithm for heterogeneity corrections. 6X-FFF beam produced highly conformal radiosurgical dose distribution to the target and reduced lung SBRT fraction duration to less than 10 min for a single dose of 30 Gy, significantly improving patient comfort and clinic workflow. Early follow-up CT imaging results (mean, 8 months) show high local control rates (100%) with no acute lung or rib toxicity. Longer clinical follow-up in a larger patient cohort managed in this fashion is underway to further validate this treatment approach.
引用
收藏
页码:6 / 12
页数:7
相关论文
共 39 条
  • [21] Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size
    Huang, Baotian
    Wu, Lili
    Lin, Peixian
    Chen, Chuangzhen
    RADIATION ONCOLOGY, 2015, 10
  • [22] Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size
    Baotian Huang
    Lili Wu
    Peixian Lin
    Chuangzhen Chen
    Radiation Oncology, 10
  • [23] 30 Gy single dose stereotactic body radiation therapy (SBRT): Report on outcome in a large series of patients with lung oligometastatic disease
    Osti, M. F.
    Agolli, L.
    Valeriani, M.
    Reverberi, C.
    Bracci, S.
    Marinelli, L.
    De Sanctis, V.
    Cortesi, E.
    Martelli, M.
    De Dominicis, C.
    Minniti, G.
    Nicosia, L.
    LUNG CANCER, 2018, 122 : 165 - 170
  • [24] Establishing stereotactic body radiotherapy with flattening filter free techniques in the treatment of pulmonary lesions - initial experiences from a single institution
    Juliane Rieber
    Eric Tonndorf-Martini
    Oliver Schramm
    Bernhard Rhein
    Laila König
    Sebastian Adeberg
    Eva Meyerhof
    Angela Mohr
    Jutta Kappes
    Hans Hoffmann
    Jürgen Debus
    Stefan Rieken
    Radiation Oncology, 11
  • [25] Establishing stereotactic body radiotherapy with flattening filter free techniques in the treatment of pulmonary lesions - Initial experiences from a single institution
    Tonndorf-Martini, E.
    Rieber, J.
    Schramm, O.
    Rhein, B.
    Koenig, L.
    Adeberg, S.
    Meyerhof, E.
    Mohr, A.
    Kappes, J.
    Hoffmann, H.
    Debus, J.
    Rieken, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 119 - 120
  • [26] Establishing stereotactic body radiotherapy with flattening filter free techniques in the treatment of pulmonary lesions - initial experiences from a single institution
    Rieber, Juliane
    Tonndorf-Martini, Eric
    Schramm, Oliver
    Rhein, Bernhard
    Koenig, Laila
    Adeberg, Sebastian
    Meyerhof, Eva
    Mohr, Angela
    Kappes, Jutta
    Hoffmann, Hans
    Debus, Juergen
    Rieken, Stefan
    RADIATION ONCOLOGY, 2016, 11
  • [27] Potential reduction of lung dose via VMAT with jaw tracking in the treatment of single-isocenter/two-lesion lung SBRT
    Pokhrel, Damodar
    Sanford, Lana
    Halfman, Matthew
    Molloy, Janelle
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (05): : 55 - 63
  • [28] Dose Rate Dosimetric Effects During the 6 MV Flattening Filter Free RapidArc-Based Stereotactic Body Radiation Therapy On Lung
    Dumitru, N.
    Pudasaini, M.
    Pella, S.
    Leventouri, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E333 - E333
  • [29] Retrospective dose reconstruction of prostate stereotactic body radiotherapy using cone-beam CT and a log file during VMAT delivery with flattening-filter-free mode
    Imae, Toshikazu
    Haga, Akihiro
    Watanabe, Yuichi
    Takenaka, Shigeharu
    Shiraki, Takashi
    Nawa, Kanabu
    Ogita, Mami
    Takahashi, Wataru
    Yamashita, Hideomi
    Nakagawa, Keiichi
    Abe, Osamu
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (03) : 238 - 248
  • [30] Retrospective dose reconstruction of prostate stereotactic body radiotherapy using cone-beam CT and a log file during VMAT delivery with flattening-filter-free mode
    Toshikazu Imae
    Akihiro Haga
    Yuichi Watanabe
    Shigeharu Takenaka
    Takashi Shiraki
    Kanabu Nawa
    Mami Ogita
    Wataru Takahashi
    Hideomi Yamashita
    Keiichi Nakagawa
    Osamu Abe
    Radiological Physics and Technology, 2020, 13 : 238 - 248